2. Technical Specifications 

Table 1 –Technical Specifications of AER800-1PVL , AER800-4PVL box, 

AER800-8PVL box, 

 

Operating 

Environment

 

Temperature

 

-40

℃~

+65

 

Relative Humidity 

5%

95% (Non-condensing) 

Input Power Voltage

 

DC36V~DC72V

 

Power Consumption 

Less than 0.3W( per port ) 

Lightning-proof 

grade 

4000V(10/700μS) 

Number of supported 

subscribers 

AER800-1PVL 

1 ADSL subscriber 

AER800-4PVL 

5 ADSL subscribers 

AER800-8PVL 

9 ADSL subscribers 

Dimension(LWH) 

AER800-1PVL 

Box 

160mm

×

70mm

×

48mm 

AER800-4PVL 

Box 

215mm

×

290mm

×

82mm

 

AER800-8PVL 

Box 

315mm

×

290mm

×

82mm

 

3. Application 

3.1 Equipment connection diagram: 

 

 

 

 

Figure 1

Line Power VDSL2 Loop Extender Connection Diagram 

L1: The twist pair connecting extender to DSLAM. 

L2: The twist pair connecting extender to Modem. 

Modem 

CPE

 

 

L2 

L1 

VDSL2+POTS 

PBX 

POTS 

CO

 

VDSL2 Loop 

Extender 

Splitter 

DSLAM 

VDSL2+POTS 

Summary of Contents for AER800-1PVL

Page 1: ...WIDEAREA Telecommunication Technology Co Ltd Line Power VDSL2 Loop Extender Installation Manual Version 1 0 Please read this document carefully before installation...

Page 2: ...eep this manual handy for ease of reference during installation and troubleshooting The contents of this document may be updated in the future without prior notice This booklet was created with thorou...

Page 3: ...ations 4 3 Application 4 4 Physical Structure 5 4 1 AER800 1PVL Box 6 4 2 AER800 4PVL Box 6 4 3 AER800 8PVL Box 7 4 4 AER800 C1PVL 7 5 Installation Procedure 7 5 1 Unpack 7 5 2 Line Power VDSL2 Loop E...

Page 4: ...am bit rate and bring more stable and reliable VDSL2 broadband service to those longer users Feature Fully compatible with ITU T G 993 2 G994 1 Fully compatible with all the VDSL2 equipments which com...

Page 5: ...Lightning proof grade 4000V 10 700 S Number of supported subscribers AER800 1PVL 1 ADSL subscriber AER800 4PVL 5 ADSL subscribers AER800 8PVL 9 ADSL subscribers Dimension LWH AER800 1PVL Box 160mm 70m...

Page 6: ...r to CPE 0 6Km 1 8Km 3Kft 6Kft DSLAM CPE 1 5Km 2 7Km 5Kft 9Kft 4 Physical Structure AER800 1PVL Stand alone 1 port unit AER800 4PVL Box A Box for up to 5 AER800 C1PVL cards AER800 8PVL Box A Box for u...

Page 7: ...y Co Ltd Table 4 Twist pair Connection Description of AER800 1PVL 4 2 AER800 4PVL Box Figure 3 AER800 4PVL Box Color Connection Orange White A B to DSLAM Green White A B to Modem AER800 C1PVL Subscrib...

Page 8: ...existing loop plant CO connects the line from the DSLAM to AER800 C1PVL CPE connects the line to the customer modem 5 Installation Procedure 5 1 Unpack When unpacking the equipment be sure to check t...

Page 9: ...ess than 2 5mm2 13 AWG diameter is required as ground wire One end of the wire should connect to Loop Extender s ground terminal The other end of the wire should connect to a good grounding point Grou...

Page 10: ...s possible elsewhere Lack of bonding will allow significant interference from AC power AM radio electric fences and similar problems Lack of bonding will also make you a prime target for lightning and...

Page 11: ...p extender is not connected properly Correct the cable connection or check whether the distance between the DSLAM extender and Modem is within recommended values L1 or L2 is too short Check that loop...