Weldarc 135, 145, 185 | Operator Manual | Model No MC110-0 / MC111-0 / MC112-0
9
8
2 RECEIVING
Check the equipment received against the
shipping invoice to make sure the shipment
is complete and undamaged. If any damage
has occurred in transit, please immediately
notify your supplier.
The Weldarc inverter package contains;
– Weldarc Inverter Power Source
– Twist-lock Electrode Holder & Cable
– Work Clamp & Cable
– (This) Operating Manual
Optionally available
– TIG Torch with Gas Valve TIG001 for
Weldarc 145
– TIG Torch with Gas Valve TIG002 for
Weldarc 185
– Argon flow gauge regulator REG003
3 SPECIFICATIONS
Manufactured to Australian Standard - AS60974.1
VRD Complies with - AS1674.2 Category C.
WELDARC 135
WELDARC 145
WELDARC 185
Primary Voltage
220-240 Vac,
50/60 Hz
220-240 Vac,
50/60 Hz
220-240 Vac,
50/60 Hz
Rated Primary
Current (I eff)
9.9 Amps
8.5 Amps
12.5 Amps
Maximum Primary
Current (I max)
22.2
Amps
19
Amps
25
Amps
Rated Output
@ 40°C
Duty cycle based on
10 minute cycle time
Stick
135 Amps, 25.4 V,
20% duty
78 Amps, 23.1 V,
60% duty
60 Amps, 22.4 V,
100% duty
Stick
145 Amps, 25.8 V,
20% duty
56 Amps, 22.2 V,
100% duty
TIG
145
Amps, 15.8 V,
20% duty
56 Amps, 12.2 V,
100% duty
Stick
185 Amps, 27.4 V,
25% duty
92 Amps, 23.7 V,
100% duty
TIG
185
Amps, 17.4 V,
25% duty
92 Amps, 13.7 V,
100% duty
If the supply cable is damaged it must
be replaced by the manufacturer, their
service agent or a similarly qualified
person.
IMPORTANT NOTICE: Warranty may
be voided if equipment is powered
from an unsuitable engine driven
generator.
Generators should have continuous
rating and incorporate output voltage
regulation. Refer to Specifications for
minimum generator capacity.
Generators without voltage regulation
must have a minimum capacity of 10 kW.