Whyte WSCR504 Instruction Manual Download Page 8

WSCR508 8-Way dSCR

WSCR512 12-Way dSCR

WSCR516 16-Way dSCR

290-2340MHz

290-2340MHz

290-2340MHz

47-790MHz

47-790MHz

47-790MHz

Yes

Yes

Yes

4 SAT + 1 TERR

4 SAT + 1 TERR

4 SAT + 1 TERR

4 SAT + 1 TERR

4 SAT + 1 TERR

4 SAT + 1 TERR

8

12

16

Yes

Yes

Yes

No

No

No

-4dB

-4dB

-4dB

-4dB

-4dB

-4dB

-35dB~+25dB (AGC)

-35dB~+25dB (AGC)

-35dB~+25dB (AGC)

+8dB±2dB

+8dB±2dB

+8dB±2dB

AGC

AGC

AGC

15dB

15dB

15dB

0/-10/-20dB

0/-10/-20dB

0/-10/-20dB

62 ~ 117dBµV

62 ~ 117dBµV

62 ~ 117dBµV

52 ~ 108dBµV

52 ~ 108dBµV

52 ~ 108dBµV

85 dBµV (AGC)

85 dBµV (AGC)

85 dBµV (AGC)

107 dBµV

107 dBµV

107 dBµV

Yes

Yes

Yes

18V DC

18V DC

18V DC

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

Yes

Yes

Yes

TBA

TBA

TBA

Legacy

Sky UK dSCR

EN50494

EN50607

Legacy

Sky UK dSCR

EN50494

EN50607

Legacy

Sky UK dSCR

EN50494

EN50607

16

16

16

22K Tone & Voltage

22K Tone & Voltage

22K Tone & Voltage

Diseqc commands

Diseqc commands

Diseqc commands

>43dB

>43dB

>43dB

>36dB

>36dB

>36dB

>10dB / >10dB

>10dB / >10dB

>10dB / >10dB

>8dB / >8dB

>8dB / >8dB

>8dB / >8dB

>8dB

>8dB

>8dB

LED

LED

LED

LED

LED

LED

Yes

Yes

Yes

Yes

Yes

Yes

TBA

TBA

TBA

TBA

TBA

TBA

 

 

Model

WSCR504 4-Way dSCR

WSCR506 6-Way dSCR

Frequency Range

SAT

290-2340MHz

290-2340MHz

TERR

47-790MHz

47-790MHz

Quattro/Wideband LNB Switch

(2 SAT reception when using 2 x WB LNB’s)

Yes

Yes

Inputs (F Connector)

4 SAT + 1 TERR

4 SAT + 1 TERR

Trunk Outputs (F Connector)

4 SAT + 1 TERR

4 SAT + 1 TERR

Tap Output Ports (F Connector)

4

6

Trunk DC Pass

SAT

Yes

Yes

TERR

No

No

Trunk Through

Loss (nom)

SAT

-4dB

-4dB

TERR

-4dB

-4dB

Gain

SAT

-35dB~+25dB (AGC)

-35dB~+25dB (AGC)

TERR

+8dB±2dB

+8dB±2dB

Gain Control

SAT

AGC

AGC

TERR

15dB

15dB

Protean Tap (ATT Switch) TERR

0/-10/-20dB

0/-10/-20dB

Min/Max Input

Signal Level

SAT

62 ~ 117dBµV

62 ~ 117dBµV

TERR

52 ~108dBµV

52 ~ 108dBµV

Max Output

Signal Level

SAT (Legacy/dSCR)

85 dBµV (AGC)

85 dBµV (AGC)

TERR

107 dBµV

107 dBµV

TERR 12V DC Supply (switchable)

Yes

Yes

Power Supply Voltage

18V DC

18V DC

Powering

Via DC In

Yes

Yes

Via SAT trunks

(remote)

Yes

Yes

Via STB

No

No

Power from DC In to Input & Output SAT Trunks

Yes

Yes

Consumption Min / Max @18V

0.1A / 0.28A

TBA

Compatibility (Auto Switching)

Legacy

Sky UK dSCR

EN50494

EN50607

Legacy

Sky UK dSCR

EN50494

EN50607

dSCR User Bands per port

16

16

Switching Commands

Legacy

22K Tone & Voltage

22K Tone & Voltage

dSCR

Diseqc commands

Diseqc commands

Isolation

Tap Port to Port

>43dB

>43dB

Trunk Port to Port

>36dB

>36dB

Return Loss

SAT Trunk In/Out

>10dB / >10dB

>10dB / >10dB

TERR Trunk In/Out

>8dB / >8dB

>8dB / >8dB

Tap Output Ports

>8dB

>8dB

SCR/Legacy Mode Indication (per port)

LED

LED

Power Indication

LED

LED

Earth Lug

Yes

Yes

Earth Terminal Bars (tap output ports)

Yes

Yes

Dimensions (HxWxD)

160x215x43mm

TBA

Weight

450g

TBA

 

 

Whyte

www.whytetechnologies.com

www.whytetechnologies.com

14

15

SPECIFICATIONS

SPECIFICATIONS

Yes

Yes

WSCR506 6-Way dSCR

In the interest of continuous improvement, all specifications of products are subject to change without notice.

Summary of Contents for WSCR504

Page 1: ...DSCR MULTISWITCH INSTRUCTION MANUAL www whytetechnologies com MODELS WSCR504 WSCR506 WSCR508 WSCR512 WSCR516...

Page 2: ...ng point using minimum 4mm diameter earth cable PRECAUTIONS To ensure trouble free operation Do not remove the cover of the Multiswitch or disassemble it as this will invalidate the guarantee The fema...

Page 3: ...automatically detected and switched over on a per subscriber port basis Terrestrial signal levels are controlled via a manual Gain Control knob and a selectable Protean Tap which permits a wide range...

Page 4: ...n stand alone mode when powered directly Whyte via the 18V Auxiliary Input by using a Whyte Power Supply Unit sold separately Any unused open SAT TERR Trunk Outputs must be terminated using 75 DC Bloc...

Page 5: ...nsure that this is also water tight Ensure that all drop cables have drip loops prior to their entering the building Connect the SAT and TERR drop cables to the corresponding Satellite and TERR Inputs...

Page 6: ...is not available such as Supply Unit may be conveniently fitted elsewhere whereby th using coaxial cable 5 Whyte Earth Bonding Earth bond the Multiswitch Make sure that the Earth B Multiple Earthing p...

Page 7: ...www whytetechnologies com www whytetechnologies com 12 13 Whyte EXAMPLE CONFIGURATION Figure 4 EXAMPLE CONFIGURATION Hybrid IRS...

Page 8: ...ap Output Ports F Connector 4 6 Trunk DC Pass SAT Yes Yes TERR No No Trunk Through Loss nom SAT 4dB 4dB TERR 4dB 4dB Gain SAT 35dB 25dB AGC 35dB 25dB AGC TERR 8dB 2dB 8dB 2dB Gain Control SAT AGC AGC...

Page 9: ...hyteTech WhyteTechnologies Whyte Technologies WhyteTechnologies Whyte Technologies Chevron Distribution Ltd Unit 12 13 Watermill Business Centre Edison Road Enfield EN3 7XF Phone 0330 999 1980 E mail...

Reviews: