SAFETY

The Multiswitches are intended for indoor use only. Do not install the Multiswitch 

in damp, humid, hot or dusty areas.

Switch  off  and  remove  the  power  supply  when  making  connections  to  the 

Multiswitch to avoid damaging the unit. 

Always  earth  bond  the  Multiswitch  using  the  Earth  Bonding  Lug  and/or  the 

Earth  Terminal  Bars  to  a  suitable  earth  bonding  point  using  minimum  4mm² 

diameter earth cable.

PRECAUTIONS

To ensure trouble free operation:

Do  not  remove  the  cover  of  the  Multiswitch  or  disassemble  it  as  this  will 

invalidate the guarantee.

The  female  F  connectors  on  this  unit were  designed  for  use with  '100'  type 

coaxial cable with a centre core diameter of 1mm². When using larger CT125 

or  CT167  cables,  you  must  ensure  that  suitable  F  connectors  with  reducing 

pins are used otherwise damage to the unit will occur which will invalidate the 

guarantee. 

Do not over tighten the F connectors (finger tight only).

GUARANTEE 

All Whyte  products  are  guaranteed  for  a  period  of  4 years  from  the  date  of 

purchase against defects. Within this guarantee period, Whyte Technologies will 

repair or replace the faulty product. In the unlikely event, please return any faulty 

products to your dealer. 

Summary of Contents for WSCR504

Page 1: ...DSCR MULTISWITCH INSTRUCTION MANUAL www whytetechnologies com MODELS WSCR504 WSCR506 WSCR508 WSCR512 WSCR516...

Page 2: ...ng point using minimum 4mm diameter earth cable PRECAUTIONS To ensure trouble free operation Do not remove the cover of the Multiswitch or disassemble it as this will invalidate the guarantee The fema...

Page 3: ...automatically detected and switched over on a per subscriber port basis Terrestrial signal levels are controlled via a manual Gain Control knob and a selectable Protean Tap which permits a wide range...

Page 4: ...n stand alone mode when powered directly Whyte via the 18V Auxiliary Input by using a Whyte Power Supply Unit sold separately Any unused open SAT TERR Trunk Outputs must be terminated using 75 DC Bloc...

Page 5: ...nsure that this is also water tight Ensure that all drop cables have drip loops prior to their entering the building Connect the SAT and TERR drop cables to the corresponding Satellite and TERR Inputs...

Page 6: ...is not available such as Supply Unit may be conveniently fitted elsewhere whereby th using coaxial cable 5 Whyte Earth Bonding Earth bond the Multiswitch Make sure that the Earth B Multiple Earthing p...

Page 7: ...www whytetechnologies com www whytetechnologies com 12 13 Whyte EXAMPLE CONFIGURATION Figure 4 EXAMPLE CONFIGURATION Hybrid IRS...

Page 8: ...ap Output Ports F Connector 4 6 Trunk DC Pass SAT Yes Yes TERR No No Trunk Through Loss nom SAT 4dB 4dB TERR 4dB 4dB Gain SAT 35dB 25dB AGC 35dB 25dB AGC TERR 8dB 2dB 8dB 2dB Gain Control SAT AGC AGC...

Page 9: ...hyteTech WhyteTechnologies Whyte Technologies WhyteTechnologies Whyte Technologies Chevron Distribution Ltd Unit 12 13 Watermill Business Centre Edison Road Enfield EN3 7XF Phone 0330 999 1980 E mail...

Reviews: