SAFETY

The Multiswitches are intended for indoor use only. 

Do not install the Multiswitch in damp, humid, hot or dusty areas.

Switch off and remove the power supply when making connections to the 

Multiswitch to avoid damaging the unit. 

Always earth bond the Multiswitch using the Earth Bonding Lug and/or the 

Earth Terminal Bars to a suitable earth bonding point using minimum 4mm² 

diameter earth cable.

PRECAUTIONS

To ensure trouble free operation: 

Do  not  remove  the  cover  of  the  Multiswitch  or  disassemble  it  as  this will 

invalidate the guarantee.

The female F connectors on this unit were designed for use with '100' type 

coaxial cable with a centre core diameter of 1mm². When using larger CT125 

or CT167 cables, you must ensure that suitable F connectors with reducing 

pins are used otherwise damage to the unit will occur which will invalidate the 

guarantee. 

Do not over tighten the F connectors (finger tight only).

GUARANTEE

 

All Whyte products are guaranteed for a period of 4 years from the date of 

purchase against defects. Within this guarantee period, Whyte Technologies 

will repair or replace the faulty product. In the unlikely event, please return 

any faulty products to your dealer.

The Guarantee will be deemed as void if the serial number on the product 

is removed, damaged or illegible. The Guarantee excludes defects caused by 

incorrect use, accidental damage, disassembly, water/fire/lightning damage or 

lack of ventilation. 

Summary of Contents for WATS 930

Page 1: ...Launch Amplifier INSTRUCTION MANUAL WATS 930 www whytetechnologies com In the interest of continuous improvement all specifications of products within this brochure are subject to change without notice ...

Page 2: ...CONTENTS Safety Precautions Guarantee General Description Technical Description Example Configuration Specifications 3 3 3 4 4 5 6 2 ...

Page 3: ...00 type coaxial cable with a centre core diameter of 1mm When using larger CT125 or CT167 cables you must ensure that suitable F connectors with reducing pins are used otherwise damage to the unit will occur which will invalidate the guarantee Do not over tighten the F connectors finger tight only GUARANTEE All Whyte products are guaranteed for a period of 4 years from the date of purchase against...

Page 4: ...18V Auxiliary Input or may be line powered via the HH and HL trunk lines A Whyte Power Supply Unit may be connected to the 18V Auxiliary Input which will pass power upwards and downwards via the HH and HL lines All IF trunk lines are DC passing in both directions The IF inputs provide power to the LNB irrespective of whether the amplifier is powered via the Auxiliary Input or line powered via the ...

Page 5: ...EXAMPLE CONFIGURATION WM932 WM932 WM932 Quick Fit Couplers 2 5A Power Supply Unit Short Circuit Overload Prorection Model WPSU 2 5A Input 110 240V AC 50 60Hz Output 18V 2 5A WPSU 2 5A WATS 930 SAT A SAT B ...

Page 6: ...ty Red Compliant 9 x SAT 1 x TERR Input Outputs Gain Control to all inputs Comes with Earth Bars fitted Use as standalone when powered with a Whyte PSU Slope Control to all inputs Switchable 12V DC Supply to Terrestrial input LTE Filter rejects 4G interference Colour coded inputs outputs Compact size 18V Auxiliary Input powers the amplifier injects power to the HL HH trunk The RED Compliant Whyte ...

Page 7: ...Unit 13 Watermill Business Centre Edison Road Enfield EN3 7XF Tel 0330 999 1980 info whytetechnologies com www whytetechnologies com Copyright Whyte Technologies June 2020 ...

Reviews: