SAFETY

The Multiswitches are intended for indoor use only. 

Do not install the Multiswitch in damp, humid, hot or dusty areas.

Switch off and remove the power supply when making connections to the 

Multiswitch to avoid damaging the unit. 

Always earth bond the Multiswitch using the Earth Bonding Lug and/or the 

Earth Terminal Bars to a suitable earth bonding point using minimum 4mm² 

diameter earth cable.

PRECAUTIONS

To ensure trouble free operation: 

Do  not  remove  the  cover  of  the  Multiswitch  or  disassemble  it  as  this will 

invalidate the guarantee.

The female F connectors on this unit were designed for use with '100' type 

coaxial cable with a centre core diameter of 1mm². When using larger CT125 

or CT167 cables, you must ensure that suitable F connectors with reducing 

pins are used otherwise damage to the unit will occur which will invalidate the 

guarantee. 

Do not over tighten the F connectors (finger tight only).

GUARANTEE

 

All Whyte products are guaranteed for a period of 4 years from the date of 

purchase against defects. Within this guarantee period, Whyte Technologies 

will repair or replace the faulty product. In the unlikely event, please return 

any faulty products to your dealer.

The Guarantee will be deemed as void if the serial number on the product 

is removed, damaged or illegible. The Guarantee excludes defects caused by 

incorrect use, accidental damage, disassembly, water/fire/lightning damage or 

lack of ventilation. 

Summary of Contents for 5 WB Series

Page 1: ...NCH AMPLIFIER INSTRUCTION MANUAL WATS 517WB WATS 530WB www whytetechnologies com In the interest of continuous improvement all specifications of products within this brochure are subject to change without notice ...

Page 2: ...CONTENTS Safety Precautions Guarantee General Description Product Description Technical Description Installation Instructions Example Configuration Specifications 3 3 3 4 5 6 8 12 14 2 ...

Page 3: ...00 type coaxial cable with a centre core diameter of 1mm When using larger CT125 or CT167 cables you must ensure that suitable F connectors with reducing pins are used otherwise damage to the unit will occur which will invalidate the guarantee Do not over tighten the F connectors finger tight only GUARANTEE All Whyte products are guaranteed for a period of 4 years from the date of purchase against...

Page 4: ...V Auxiliary Input injects power to all SAT lines Can be powered via any all SAT inputs or outputs SAT gain 17dB TERR gain 13dB WATS517WB SAT gain 30dB TERR gain 24dB WATS530WB The Whyte WATS 517WB WATS 530WB Series 5 WB Launch Amplifiers may be used for conventional IRS distribution Quattro LNB or as part of Wideband IRS System WB LNB where up to two wideband LNB s can be connected to the input Th...

Page 5: ...al TV Radio 3 Corner Mounting Brackets 4 Earth Terminal Lug 5 Gain Controls 6 Output SAT 7 Output TERR 8 4G 5G Terrestrial Filter 9 Slope Controls 10 LED Power Indicator 11 Auxiliary DC Input 12 TERR 12V DC Switch 1 2 7 4 8 9 10 11 5 1 3 3 6 6 12 3 3 5 ...

Page 6: ...onnected correctly in the corresponding order with respect to the LNB and the Launch Amplifier SAT inputs Ensure that the F Connectors are properly sealed against water ingress If a Composite Cable multi core coaxial cable has been used ensure that the outer jacket is not facing upwards and cannot collect rain water Check the Terrestrial Drop Cable and ensure that this has also been sealed against...

Page 7: ...nding Wire To achieve this strip away 3cm of the insulation of a length of 4mm Earth Bonding Wire See Figure 1 Unscrew the Earth Bolt on the Earth Terminal Bar to provide enough clearance to wrap the Earth Bonding Wire around the Earth Bolt See Figure 2 Tighten the Earth Bolt and route the Earth Bonding Wire to all other Earth Terminal Bars and terminate as detailed above Make sure that the Earth ...

Page 8: ...e current consumption of each LNB to be 200mA max 0 2A Connect a suitable Whyte PSU to the Auxiliary 18V DC Input If more than one PSU is required the additional PSU s may be connected to any other Multi switch Launch Amplifier Tap or Splitter within the system When all connections have been made connect the PSU to a 240V socket to power up the IRS System It is highly advisable to isolate and henc...

Page 9: ...89dBμV 5dB 25dB 5dB Consumption Min Max 18V Compatibility LED Status SAT dSCR Legacy Frequency Min Max Input Max Output Gain Trunk Loss Max 87 790MHz 52 102dBμV 90dBμV 8dB 2dB 5dB 0 1A 0 15A Sky UK EN50607 EN50494 Terrestrial SCR Mode Legacy Mode Flashing Green Solid Green VL V HL H Sat A VH V HH H Sat B TERR Q WB VL HL VH HH TERR TERR Gain WSCR508 8 Way dSCR Multiswitch ON DC 12V OFF WB LNB Q TER...

Page 10: ...dB 2dB 5dB 1A 0 15A N50607 EN50494 rrestrial Flashing Green Solid Green REC 1 REC 3 DC IN 18V REC 2 REC 4 VL HL VH HH TERR VL V HL H Sat A VH V HH H Sat B TERR Q WB TERR Gain TERR TM WSCR504 4 Way dSCR Multiswitch ON DC 12V OFF WB LNB Q 0 dB 10dB 20dB Frequency Min Max Input Output AGC Gain AGC Trunk Loss Max 290 2340MHz 64 104dBμV 89dBμV 5dB 25dB 5dB Consumption Min Max 18V Compatibility LED Stat...

Page 11: ...TERR SAT TERR SAT TERR SAT IMA 35dB EN50083 3 TERR IMA 60dB EN50083 5 SAT per trunk TERR Via DC In Via SAT Trunks Frequency Inputs F Type Connector Outputs F Type Connector Gain Gain Control Slope Control 4G 5G Switchable Filter TERR 12V DC Supply switchable Input Output Return Loss Max Output Level LNB Power Supply Max Trunk DC Pass Powering Input Earth Terminal Bar Earth Lug F Type connector wit...

Page 12: ...Unit 1 Watermill Business Centre Edison Road Enfield EN3 7XF Tel 0330 999 1980 info whytetechnologies com www whytetechnologies com Copyright Whyte Technologies May 2021 v2 ...

Reviews: