V. CONTINUOUS DRAINAGE

WATER PUMP METHOD 

One of the key features of this unit is that it has a water pump that pushes water up or over a longer distance. Us­

ing this feature will enable your unit to run maintenance free, and you will no longer have to empty a heavy reser­

voir filled with water or worry about draining your unit using gravity. 

INSTALLATION OF HOSE 

This unit comes with a 16.5 ft. water pump hose. Once installed, 

the continuous drain outlet is bypassed and the water pump mo­

tor is activated. 

1. Firmly insert the water pump hose to the outlet.

2. A click sound will be heard to confirm that the hose is properly

attached

3. Place the other end of the hose in a floor drain where water

can be expelled.

NOTE: 

Water pump motor will not activate and work if water

bucket is full.  Make sure water bucket is empty or not full when

using this drain method.

GRAVITY METHOD 

This dehumidifier also comes standard with a 3 ft. drain hose. To use gravity to drain your portable dehumidifier, it 

must be installed on a level surface or at least 12 inches above the ground, on a sturdy table or shelf unit.  When 

using the function of continuous drainage, the hose must be placed horizontally below the drainage hole. Avoid 

uneven ground and folding the hose. 

1. You can use the supplied drain hose to connect to

the continuous drainage connector.

2. Unscrew and remove the drain cover at the rear of

the appliance.

3. Remove the soft rubber stopper. Put it into the water

bucket for safe keeping.

4. Insert the drain hose through the hole of the drain

cover.

5. Connect the drain hose to the drain port.

6. Tighten the drain cover in clockwise direction on to

the rear of the appliance.

7. Place the bucket on its original location.

Drain hose 

Back of the unit 

,�

D,a;oro,o, 

o--:r• 

c,bbecstoppe, 

/Drain cover

© 

Drain cover�

1' 

Drain hose 

D, 

� 

D,a;, oo,e, 

-Drain hose

Dra;ohos� 

+

-Bucket

NOTE: 

When using continuous drainage setup, there may be some water collected in the water in the 

drain bucket 

Summary of Contents for RPD-551EWP

Page 1: ... Dehumidifier with Pump Model RPD 551 EWP INSTRUCTION MANUAL IHi lriliM Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference ...

Page 2: ...tion removal and collecting the condensation water in the internal water bucket or draining through a drain hose Please keep this user manual in a safe place for future reference This symbol on the product or its packaging indicates that the appliance can not be treated as normal domestic trash but must be handed in at a collection point for recycling electric and electronic appliances Your contri...

Page 3: ...2 I SAFETY PRECAUTIONS 4 II INTRODUCTION 5 Ill PARTS AND CONTROLS 6 IV OPERATION INSTRUCTIONS 7 8 V CONTINUOUS DRAINAGE 9 VI MAINTENANCE 10 VII TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 11 VIII TROUBLESHOOTING 12 13 WARRANTY INFORMATION 14 3 ...

Page 4: ...d to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do not use multiple socket Do not use multiple socket or of an extension cord as it may overheat and become a risk of fire Make sure the plug is clean before usage Do not turn this appliance on and off...

Page 5: ...47 6 lbs 980 ...

Page 6: ...and actual humidity on the right side The left LED display will change when timer function is acti vated and the user desired humidity level can be manually set and seen on the right LED display The humidity level can be set within a range of 30 to 90 RH Relative Humidity in 5 increments This can be controlled by pressing the UP or DOWN arrows C F SELECTOR Temperature conversion can be changed fro...

Page 7: ... the set RH is reached or when the water bucket is full When the water bucket is full the Bucket Full indication lamp will light up and the dehumidifier will stop operating Remove the water in the bucket with two hands then place the water bucket back to it s proper position the machine will start operating again This light will also illuminate when the bucket is removed or not properly inserted D...

Page 8: ...des of the appliance for good air circulation and 20 or more above the appliance NOTE 10 or more II II II II II 1O or more Air Intake I 10 or more 1 1 1 1 1 11 1 1 I 1O or more I I 1 1 iu t I ccccccc____ c J Dehumidifiers working in a basement will have little or no effect on adjacent enclosed rooms such as closets unless there is enough circulation of air in and out of the enclosed area If the ap...

Page 9: ...his dehumidifier also comes standard with a 3 ft drain hose To use gravity to drain your portable dehumidifier it must be installed on a level surface or at least 12 inches above the ground on a sturdy table or shelf unit When using the function of continuous drainage the hose must be placed horizontally below the drainage hole Avoid uneven ground and folding the hose 1 You can use the supplied dr...

Page 10: ...not clean the bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifier runs efficiently it is recommended to clean the air filter at least once every two weeks Remove the bucket and pull filter downwards Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt Rinse the air filter under warm or cold runn...

Page 11: ...ily room If your home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relative humidity inside your home and a good idea in general if your home has such underlying problems as a leaky foundation walls or inade quate ventilation or if you live in a humid area By keeping the ...

Page 12: ...iance must be placed in a space midifier is blocked Air grill may that does not restrict air flowing into the be dirty rear coil or out of the front grill Continuous mode is on Set the RH level and the appliance will stop when the set RH is reached The dehumidifier runs but Humidity setting RH is too Set the humidity level to a lower RH the room is not dry enough high We recommend setting the RH t...

Page 13: ...has an open circuit or humidity is less than 30 90 RH Humidity Sensor has short circuit or humidity is higher than 90 Lo Temperature is lower than 32 F or temperature sensor has an open circuit Hi Temperature is higher than 122 F or temperature sensor has a short circuit 13 ...

Page 14: ...le in the possession of a consumernot caused by a defect in material or workmanship Damage caused by consumer misuse tampering lack of maintenance or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations to the product by anyone other than authorized by themanu...

Reviews: