Whynter RPD-551EWP Instruction Manual Download Page 4

I. SAFETY PRECAUTIONS

WARNING 

TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK,  OR INJURY 

WHEN USING YOUR PORTABLE DEHUMIDIFIER, FOLLOW THESE 

BASIC PRECAUTIONS: 

Read all instructions before using the appliance

Never clean appliance parts with flammable fluids. The fumes can create a fire hazard.  Do not use an exces­

sively wet cloth, industrial solvents, and oil-based products to clean this appliance

Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of this or any other appli­

ance. The fumes can create a fire hazard

Do not abuse, sit on, or stand on the appliance

This appliance is not intended for use by persons (including children with reduced physical, sensory or mental

capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction con­

cerning use of the appliance by a person responsible for their safety

Children should be supervised to ensure that they do not play with the appliance

If the power cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly quali­

fied person in order to avoid a hazard

Please dispose of packing materials properly

Use the portable dehumidifier only for its intended function. This appliance is designed for household, non­

commercial use only. Any other use will void the warranty

To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other

steamy or wet areas

During installation, the power supply must not be excessively or dangerously bent or flattened

Do not tamper with controls

Make sure the plug is placed fully and firm into the wall socket.  If the wall receptacle you intend to use is not

adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install an

outlet that is appropriate to local electrical codes and requirements

Do not use multiple socket.  Do not use multiple socket or of an extension cord as it may overheat and become

a risk of fire.

Make sure the plug is clean before usage

Do not turn this appliance on and off by plugging and unplugging. Always use the ON/OFF switch

After turning the appliance off, please take the plug out of the socket

Make sure hands are dry when connecting the power plug. The appliance is equipped with a three-prong

grounded plug on the power cord for your protection. Never modify, remove or attempt to repair the plug your­

self

Do not repair, disassemble and/or modify the appliance by yourself

Always turn off the appliance when cleaning the air filter, and transporting

At the end of each season, all water must be drained from the appliance and air filter must be cleaned before

storage

Do not drink or use the water collected or drained from the appliance

Do not remove the water bucket during operation

Transport the appliance in an upright position only, or leave it in an upright position for at least 2 hours before

first use

When positioning or moving the appliance, ensure that it is not turned upside down or greater than 45

° 

or more

off level.

This appliance must be installed in an area protected from the element, such as wind, rain, water spray or

drips

Always place the appliance on even and hard and level surface that can support the unit when it is full

Ensure objects are not obstructing the exhaust and air intake

Never insert your fingers or other objects into the air intakes and air outlets

Do not operate the appliance without the air filter

THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT

FOLLOWED 

Summary of Contents for RPD-551EWP

Page 1: ... Dehumidifier with Pump Model RPD 551 EWP INSTRUCTION MANUAL IHi lriliM Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference ...

Page 2: ...tion removal and collecting the condensation water in the internal water bucket or draining through a drain hose Please keep this user manual in a safe place for future reference This symbol on the product or its packaging indicates that the appliance can not be treated as normal domestic trash but must be handed in at a collection point for recycling electric and electronic appliances Your contri...

Page 3: ...2 I SAFETY PRECAUTIONS 4 II INTRODUCTION 5 Ill PARTS AND CONTROLS 6 IV OPERATION INSTRUCTIONS 7 8 V CONTINUOUS DRAINAGE 9 VI MAINTENANCE 10 VII TIPS ON WHEN TO USE YOUR PORTABLE DEHUMIDIFIER 11 VIII TROUBLESHOOTING 12 13 WARRANTY INFORMATION 14 3 ...

Page 4: ...d to use is not adequately grounded or protected by a time delay fuse or circuit breaker have a qualified electrician install an outlet that is appropriate to local electrical codes and requirements Do not use multiple socket Do not use multiple socket or of an extension cord as it may overheat and become a risk of fire Make sure the plug is clean before usage Do not turn this appliance on and off...

Page 5: ...47 6 lbs 980 ...

Page 6: ...and actual humidity on the right side The left LED display will change when timer function is acti vated and the user desired humidity level can be manually set and seen on the right LED display The humidity level can be set within a range of 30 to 90 RH Relative Humidity in 5 increments This can be controlled by pressing the UP or DOWN arrows C F SELECTOR Temperature conversion can be changed fro...

Page 7: ... the set RH is reached or when the water bucket is full When the water bucket is full the Bucket Full indication lamp will light up and the dehumidifier will stop operating Remove the water in the bucket with two hands then place the water bucket back to it s proper position the machine will start operating again This light will also illuminate when the bucket is removed or not properly inserted D...

Page 8: ...des of the appliance for good air circulation and 20 or more above the appliance NOTE 10 or more II II II II II 1O or more Air Intake I 10 or more 1 1 1 1 1 11 1 1 I 1O or more I I 1 1 iu t I ccccccc____ c J Dehumidifiers working in a basement will have little or no effect on adjacent enclosed rooms such as closets unless there is enough circulation of air in and out of the enclosed area If the ap...

Page 9: ...his dehumidifier also comes standard with a 3 ft drain hose To use gravity to drain your portable dehumidifier it must be installed on a level surface or at least 12 inches above the ground on a sturdy table or shelf unit When using the function of continuous drainage the hose must be placed horizontally below the drainage hole Avoid uneven ground and folding the hose 1 You can use the supplied dr...

Page 10: ...not clean the bucket in a dishwasher 3 Cleaning the air filter To ensure the air intake is filtered properly and to assure that your dehumidifier runs efficiently it is recommended to clean the air filter at least once every two weeks Remove the bucket and pull filter downwards Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt Rinse the air filter under warm or cold runn...

Page 11: ...ily room If your home is musty you will want to use your portable dehumidifier especially if you have respiratory trouble or allergies This unit can also help relieve symptoms by controlling the relative humidity inside your home and a good idea in general if your home has such underlying problems as a leaky foundation walls or inade quate ventilation or if you live in a humid area By keeping the ...

Page 12: ...iance must be placed in a space midifier is blocked Air grill may that does not restrict air flowing into the be dirty rear coil or out of the front grill Continuous mode is on Set the RH level and the appliance will stop when the set RH is reached The dehumidifier runs but Humidity setting RH is too Set the humidity level to a lower RH the room is not dry enough high We recommend setting the RH t...

Page 13: ...has an open circuit or humidity is less than 30 90 RH Humidity Sensor has short circuit or humidity is higher than 90 Lo Temperature is lower than 32 F or temperature sensor has an open circuit Hi Temperature is higher than 122 F or temperature sensor has a short circuit 13 ...

Page 14: ...le in the possession of a consumernot caused by a defect in material or workmanship Damage caused by consumer misuse tampering lack of maintenance or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations to the product by anyone other than authorized by themanu...