background image

 

 11 

CLEANING AND MAINTENANCE 

To maintain the performance of the air purifier, cleaning unit regularly and replacing the filter when needed is 
highly recommended. 

1. To clean the sensor, make sure that the air purifier is switched 
off. 

2. Use a damp cotton swab and wipe the sensor, as shown. 

3. Dry the sensor with the other end of the cotton swab.  

REPLACING 2-in-1 ACTIVATED CARBON AND HEPA FILTER 

The recommended change schedule for your 2-in-1 filter pack is every 4 to 6 months under normal air quality con-
ditions or when the icon illuminates on the control panel.. 

Note: The 2-in-1 ACTIVATED CARBON AND HEPA FILTER is not washable. 

1.  Power off the air purifier. 
2.  Remove the front cover and washable pre-filter. 
3.  Replace the used filter with a new 2-in-1 Activated Carbon Filter and HEPA filter. Re-attach the pre-

filter and replace front cover. 

4.  Plug in and turn on unit. Touch and hold the 

Sleep icon for 5 seconds to reset the Air Quality 

Filter indicator. The Check Filter indicator will turn off,  the 

Home icon will illuminate and normal 

operation will resume. 

5.  Dispose of the used 2-in-1 Activated Carbon Filter and HEPA filter. Do not reuse or wash. 

 
CLEANING THE PRE-FILTER 

The Pre-Filter should be cleaned according to the level of pollution in the air of the room. 
1.  Remove the Pre-Filter from the air purifier.  
2.  Gently wash under lukewarm water for 2 to 3 minutes or until it is completely clean. Clean the Pre-Filter with 

caution as the material is fragile. Rinse with clean tap water.  

3.  Use a towel to remove any excess water from the Pre-Filter and allow to dry for 12 to 24 hours. 
4.  When Pre-Filter is completely dry, place the Pre-filter back into the air purifier. 

 
CLEANING THE PHOTOCATALYST FILTER 

The Photocatalyst Filter should be cleaned every 6 months depending on the air quality. 

Note: The Photocatalyst FIlter is not washable. 

1.  Remove the front cover and the 2-in-1 Activated Carbon Filter and HEPA filter. 
2.  Remove the Photocatalyst Filter and use a vacuum cleaner with a nozzle or brush attachment on a 

lower power setting to clean the dirt and dust from the filter. 

 

REPLACING THE UV BULB 

The UV bulb should be replaced every 6,000 working hours. This is indicated by the blinking of the UV Bulb icon 
on the control display. Please contact Whynter Service Department for purchase information of a new UV Bulb. 

 

CLEANING THE AIR PURIFIER 

The surface of the air purifier should be cleaned at least once a month or more often depending on the air quality. 

1.  Use a clean, dry cloth to wipe the external surfaces. 
2.  Use a damp cloth to remove stubborn stains and dirt build up. 
3.  Clean the air inlets and outlet with a dry cloth or a vacuum cleaner. 

CLEANING THE AIR QUALITY SENSOR 

The Air Quality Sensor can be located on the right side of the unit. For best performance, clean the sensor each 
time you replace the 2-in-1 Activated Carbon and HEPA Filter. 

Summary of Contents for EcoPure AFR-425-PW

Page 1: ...er Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference...

Page 2: ...e obtained from your local munici pal authority Thank you for choosing the Whynter EcoPure HEPA System Air Purifier Please follow the in structions provided in this user guide to obtain the very best...

Page 3: ...NFORMATION 2 SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS IDENTIFICATION 6 7 CONTROL PANEL 8 FILTRATION PROCESS INSTALLATION 9 INSTALLATION INITIAL SETUP 10 CLEANING MAINTENANCE 11 TROUBLE...

Page 4: ...supply must not be excessively or dangerously bent or flattened Do not tamper with controls Make sure the power plug is placed fully and firm into the wall socket If the wall receptacle you intend to...

Page 5: ...425 PW SW air purifier to be moved from room to room or from a home to the office as needed With an effective range of 550 square feet it is powerful enough to clean the air in any room TECHNICAL DAT...

Page 6: ...6 PARTS IDENTIFICATION FRONT VIEW BACK VIEW Handle Air Outlet Vent Power Cord REMOTE CONTROL Control Panel Remote Sensor Air Quality Sensor Air Inlet Front Cover...

Page 7: ...7 PARTS IDENTIFICATION FILTERS Front Cover Pre Filter 2 in 1 Activated Carbon HEPA Filter Photocatalyst Filter UV Bulb Activated Carbon Filter and HEPA Filter comes in a 2 in 1 Filter Pack...

Page 8: ...ome icon indicates the quality of air GREEN Good air quality BLUE Fair air quality RED Poor air quality The Check Filter icon indicates that the 2 in 1 Activated Carbon Filter HEPA filter needs to be...

Page 9: ...tocatalytic oxidation PCO is not a filtering technology as it does not trap or remove particles It eliminates and kills 99 of organic contaminants such viruses mold and bacteria by completely oxidize...

Page 10: ...emove and discard packaging materials 4 Install the Photocatalyst Filter by securely pushing into the air purifier with the pull string facing out ward 5 Install the 2 in 1 Activated Carbon and HEPA F...

Page 11: ...der lukewarm water for 2 to 3 minutes or until it is completely clean Clean the Pre Filter with caution as the material is fragile Rinse with clean tap water 3 Use a towel to remove any excess water f...

Page 12: ...et Unit always runs on the high est speeds when in Automatic Mode Air Quality Sensor has dust on it and must be cleaned Clean Air Quality Sensor See page 9 Odor and smoke are not removed Filters are d...

Page 13: ...misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or...