TROUBLESHOOTING 

Many common upright freezer problems are easily resolved. Try the troubleshooting suggestions below 
to see if the problems can be resolved before having to contact the service department. 

The following characteristics are normal and should not be looked upon as a problem: 

A gentle trickling (water) sound caused by coolant flowing through the pipe.

Compressor operating at high temperature.

Problem 

Possible Cause 

Probable Correction 

The machine won't 
operate. 

The upright freezer is unplugged

The fuse is blown

The upright freezer power switch
is OFF

Plug the upright freezer in

Replace fuse

Turn the upright freezer power on by
turning the temperature control knob

Noise during operation 

The feet are not leveled and
locked

Certain sounds are normal

Level and lock the feet. See Leveling
the upright freezer

See “Normal Sounds”

The upright freezer does 
not cool sufficiently 

Door being opened frequently

Door left open for a while

Not enough adequate clearance

Upright Freezer is overfilled

Ambient temperature is high

Refrain from opening the upright
freezer door  recurrently

Make sure to close upright freezer
door

Follow recommended clearance
measurements. See Installation
Clearances

Foods defrosting 

Unit is OFF

Freezer is unplugged

The fuse is blown/circuit breaker
is tripped

Door is open

Too frequent or too long door
openings

Move the control to a temperature
setting

Push the plug completely into the
outlet

Replace fuse or reset the breaker

Check to see if an object is holding
the door open

Excessive frost buildup 

Door/lid left open too frequent or
too long door openings

High humidity

Check to see if an object is holding
the door open

Freezer external surface is 
warm 

The external freezer walls can be
as much as  30°F warmer than
room temperature

This is normal while the compressor
works to transfer heat from inside the
freezer cabinet

Moisture forms on inside 
freezer walls 

Weather is hot and humid, which
increases internal rate of frost
buildup

Door may not be seating properly

Door is kept open too long, or is
opened too frequently

This is normal

Check door installation

Open the door less often

Odors in freezer 

Interior needs to be cleaned

Food with strong odors are in the
freezer

Clean interior with sponge, warm
water, and baking soda

Summary of Contents for CUF-110

Page 1: ...al MODEL CUF 110 CUF 112SS Congratulations on your new WHYNTER product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference CUF 110 CUF 112SS Stainless Steel Black ...

Page 2: ...Safety Precautions 4 Electrical Requirements 5 Installation 6 Leveling the upright freezer 7 Reversing the door swing 8 Operation 9 Defrosting 10 Cleaning and maintenance 10 11 Energy Saving Tips 11 Troubleshooting 12 Warranty Information 13 ...

Page 3: ... 1 Cabinet 2 Compressor mounting panel 3 Bottom hinge 4 Door 5 Door seal 6 Powder coated steel wire shelf 7 Leveling leg 8 Smaller bottom hinge leveling leg 9 Top hinge 10 Top hinge cover 11 Thermostat control knob 12 Lock ...

Page 4: ...glass cleaning products Never use harsh chemicals or solvents Do not use this upright freezer with an extension cord or power strip Please ensure that the appliance is plugged directly into the electrical outlet Close the upright freezer door immediately after opening Avoid placing the upright freezer near external heat sources or direct sunlight Make sure the upright freezer is placed on a flat l...

Page 5: ...e and local codes and ordinances Technical Information Voltage 115V Frequency 60Hz Input Power 79W Refrigerant R600a Unit Temperature Range 10 2 F Operating Temperature Range 60 85 F Rated Current 1 1A Volume 1 1 cu ft Weight 42 lbs Unit Dimensions 18 6 W x 17 7 D x 19 4 H Control Type Mechanical Defrost Type Manual Lock Yes Cabinet Shelves Total 1 NOTE Technical data and performance information p...

Page 6: ...ate the unit in an enclosed area such as a closed cabinet Before connecting the upright freezer to the power source let it stand upright for approximately 4 hours This will reduce the possibility of a malfunction in the cooling system from handling during transportation To ensure proper service access and ventilation allow at least 4 clearance at rear and 1 at top and sides The installation should...

Page 7: ...f the feet as follows Turn the leveling feet to the right to lower that side of the upright freezer Turn the leveling feet to the left to raise that side of the upright freezer Reversing the Door Swing Tools needed Flathead screwdriver Phillips screwdriver Note To avoid injury to yourself and property we recommend someone assist you during the door reversal process This appliance has the capabilit...

Page 8: ...he top of the appliance Slide the door back on to the top hinge Ensure the door is face up Replace the top hinge cover on the top hinge by pressing down until it clicks into position 4 Screw the bottom hinge into place on the new side Replace the foot on the other side 5 Ensure the door is aligned horizontally and vertically and that the seal is closed on all sides before finally tightening the bo...

Page 9: ...efrigerant flowing in your upright freezer A gentle trickling water sound caused by coolant flowing through the pipe Items stored on top of the upright freezer can also make noises Store Frozen Food When using the upright freezer for the first time or after defrosting turn the temperature control to set 6 for at least two hours before introducing the food to be stored All frozen food products you ...

Page 10: ...right Freezer Keep the finish clean Wipe with a clean cloth lightly dampened with appliance polish wax or mild liquid dishwashing detergent Dry and polish with a clean soft cloth Do not wipe the freezer with a soiled dishwashing cloth or wet towel Do not use scouring pads powdered cleaners bleach or cleaners containing bleach Inside Clean the inside of your freezer at least once a year It is recom...

Page 11: ... CASE OF EXTENDED POWER FAILURE Keep freezer door closed Your freezer will keep food frozen for 24 hours provided warm air is not admitted If freezer is out of operation for 24 hours or more add dry ice Leave ice in large pieces Add more ice as required NOTE Handling of dry ice can cause freezing of the hands gloves or other protection is recommended If dry ice is not available move food to a froz...

Page 12: ...rain from opening the upright freezer door recurrently Make sure to close upright freezer door Follow recommended clearance measurements See Installation Clearances Foods defrosting Unit is OFF Freezer is unplugged The fuse is blown circuit breaker is tripped Door is open Too frequent or too long door openings Move the control to a temperature setting Push the plug completely into the outlet Repla...

Page 13: ...parts will be the responsibility of the original owner of the unit THIS WARRANTY DOES NOT COVER Acts of God such as fire flood hurricanes earthquakes and tornadoes Improper power supply such as power surge low voltage defective household wiring or inadequate fuses Use in commercial or industrial applications Damage accidental or otherwise to the Whynter Upright Freezer while in the possession of a...

Reviews: