background image

 

 18 

TROUBLESHOOTING 

Problem 

Possible Causes 

Solutions 

The unit has worked for a long 
time, but the room is not cold 
enough

 

 

Windows or doors are open

 

 

There are too many people in the 
room

 

 

There is direct sunshine into the 
room

 

 

 

The room is a kitchen or with many 
heat-producing appliances

 

 

There is a server in the room

 

 

The room is too large

 

 

Close all windows and doors

 

 

You may need additional cooling or 
another air conditioner

 

 

Close curtains or blinds and try to min-
imize the amount of direct sunlight into 
the room

 

 

You may need additional cooling or 
another air conditioner

 

The unit is very noisy

 

 

The unit is not level

 

 

 

The surface underneath the unit is 
uneven

 

 

Low power voltage

 

 

Make sure the unit is on hard, level 
and stable surface

 

 

Move the unit to a location with a level 
and hard floor

 

 

Make sure the wall outlet and support 
the required power consumption of the 
air conditioner and do not use an ex-
tension cord

 

The unit leaks water

 

 

The unit is tilted or not leveled

 

 

The water tank is full

 

 

Make use the unit is leveled

 

 

Drain water from the drain plug at the 
back of the air conditioner

 

Fan speed cannot be changed

 

 

Fan speed differences are not very 
noticeable

 

 

The fan speed difference is not very 
noticeable when the compressor is on. 
Try setting the unit to Fan only mode, 
you should be able to hear the differ-
ence between high and low fan speed 
settings.

 

Summary of Contents for ARC-148MHP

Page 1: ...ILVERSHIELD FILTER PLUS AUTOPUMP Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in a safe place for future reference Model ARC 148MHP INSTRUCTION MANUAL ...

Page 2: ...FORMATION 3 SAFETY PRECAUTIONS 4 INTRODUCTION TECHNICAL DATA 5 PARTS IDENTIFICATION 6 7 CONTROL PANEL 8 INSTALLATION 9 11 OPERATION INSTRUCTIONS 12 14 REMOTE CONTROL 15 CARE AND MAINTENANCE 16 TROUBLESHOOTING 17 18 WARRANTY INFORMATION 19 ...

Page 3: ...s product can be obtained from your local municipal au thority Thank you for choosing the Whynter 14 000 BTU Portable Air Conditioner and Heater with 3M Sil vershield filter Please follow the instructions provided in this user guide to obtain the very best per formance from your portable air conditioner and take full advantage of the many features your port able air conditioner offers you We trust...

Page 4: ...ush the exhaust hose while in use Always allow at least 20 of clearance around the unit for ventilation Do not use this unit inside closets cabi nets and or cramped spaces between furniture This unit is optimized to operate in an ambient temperature of 64 F 90 F This unit must be installed in an area protected from the element such as wind rain water spray or drips The unit should not be located n...

Page 5: ...ECO FRIENDLY CFC free GREEN R 410A refrigerant and lead free RoHS compliant components TECHNICAL DATA Model ARC 148MHP Operational Modes Auto Air conditioner Fan Heater or Dehumidifier Cooling Capacity 14000 BTU Heating Capacity 11000 BTU Coverage Area 500 sq ft Dehumidifying Capacity 71 Pts day Fan Speed 3 Fan Speeds Filters 3M Filter and Silvershield washable pre filter Thermostat Control Range ...

Page 6: ... Vent Louvers Casters four Upper Air Filter Air Outlet Vent Power Cord Upper Air Intake Upper Drain Port Lower Air Filter Lower Air Intake Compressor Lower Drain Port Power Plug Socket use when storing unit Power Cord Buckle use when storing unit Handle Heat Pump Drain ...

Page 7: ...duces the risk of fire due to arcing faults in the power supply cord Please follow the instructions below to ensure that LCDI plug works properly 1 Plug the power cord to a grounded wall outlet Do not plug to a power strip or extension cord 2 Press the TEST button on the plug This should trip the plug and cut the power to the air condi tioner If the plug does not trip and the unit comes on please ...

Page 8: ...t the air flow direction Up and Down Buttons Adjusts set temperature 1 C 2 F incre ments or timer hours 0 24 hours This unit is capable of displaying set temperature in Fahrenheit or in Celsius To convert from one to the other press and hold the Up and Down buttons for 3 sec onds LED Display In Cool mode shows set temperature in C or F and AU TO timer setting In DRY and FAN only modes shows room t...

Page 9: ...he remaining 2 of moisture will be collected in the water tank of the air conditioner When the water reservoir reaches its maximum level the unit will beep 8 times and the digital display will show P1 When the unit displays P1 all operation modes will be disabled temporarily while the fan continuously run ning The P1 code will disappear when the water is completely drained Manual drainage Fig 1a I...

Page 10: ...ength We do not recommend extending the exhaust hose more than 9 long If you are interested in purchasing an addi tional 5 exhaust hose please contact info whynter com for retail sales information WINDOW KIT INSTALLATION When you use this air conditioner unit hot air must be exhausted out of the room to complete the air exchange of the condenser When the unit is operating in fan only mode installa...

Page 11: ...l to the length and seal the open gap between the top window sash and outer window sash Shown in Fig 5d WINDOW KIT INSTALLATION IN A SLIDING WINDOW DOOR 1 Open window or sliding door for approx imately 5 2 Cut the foam seal adhesive type to the proper length and attach it to the bot tom of the door window Fig 6a 3 Adjust the length of the window bars to the same length and width of the opening of ...

Page 12: ...ings DRY DEHUMIDIFYING ONLY MODE In this mode the air conditioner only dehumidifies the room the compressor will activate intermittently depending on the ambient temperature and the fan speed is set to LOW To activate this function mode press the MODE button until the DRY indicator light comes on Please note that when switching function mode there will be an approxi mately 3 minute transition time...

Page 13: ...o up to 10 hours followed by 1 hour increment up to 24 hours When the delay time set has elapsed the air conditioner switches off To cancel the delayed switch off function turn off the air conditioner or adjust the time set ting to 0 0 SETTING DELAYED SWITCH ON TIMER With the air conditioner is off press the TIMER button The TIMER ON light will come on Then set the desired time delay ON hours by p...

Page 14: ...high pitched sound Water running from the evaporator to the water tank may make a splashing sound Refrigerant flowing may make a gurgling sound Fan sound may come from front and back air vents COMPRESSOR LOCK OUT This portable air conditioner is optimized to operate in an ambient temperature of 64 F 90 F The compressor cir cuit has an automatic 3 minute time delayed start if the unit is turned off...

Page 15: ...A 1 5V Batteries included in the remote control Always change both batteries at the same time INDICATOR FUNCTION 1 Mode Indicator Displays the current selected mode Auto Cool Dry Heat or Fan 2 Lock Indicator Indicates current setting is locked and cannot be changed 3 Temp Timer Display Displays set temperature 4 Fan High Displays the selected high fan speed 5 Fan Medium Displays the selected mediu...

Page 16: ... the filter in place CLEANING THE AIR CONDITIONER Always switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner Use a soft damp cloth to wipe the body of the unit Never use harsh chemicals oil based products deter gents chemically treated cloths or other cleaning solutions These could possibly damage the body of the air condition er ...

Page 17: ... its time delay The set temperature is too high The internal water reservoir is full and P1 appears on display This unit is designed to work in ambi ent temperatures of 63 F to 90 F Press the MODE button until the COOL light is shown on the display Give the compressor 3 minutes to turn on after the Cooling mode has been selected Set the air conditioner to a lower tem perature It is recommended to ...

Page 18: ...nit is very noisy The unit is not level The surface underneath the unit is uneven Low power voltage Make sure the unit is on hard level and stable surface Move the unit to a location with a level and hard floor Make sure the wall outlet and support the required power consumption of the air conditioner and do not use an ex tension cord The unit leaks water The unit is tilted or not leveled The wate...

Page 19: ...ship Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions Damage to the finish of the case or other appearance parts caused by wear Damage caused by repairs or alterations to the product by anyone other than authorized by the manufacturer Freight and Insurance cost for the warranty service DISCLAIMER OF IMPLIED WARRANTIES LIMI...

Reviews: