background image

Whynter Compact Size 11,000 BTU Portable Air Conditioner

Model # : ARC-115WG

Congratulations on your new Whynter product. To ensure proper operation, please read this Instruction Manual carefully before 

using this product. Keep this manual in a safe place for future reference. 

Summary of Contents for ARC-115WG

Page 1: ...table Air Conditioner Model ARC 115WG Congratulations on your new Whynter product To ensure proper operation please read this Instruction Manual carefully before using this product Keep this manual in...

Page 2: ...THE RIGHT LOCATION AMBIENT TEMPERATURE RANGE FOR UNIT OPERATION TECHNICAL DATA ACCESSORIES WINDOW KIT INSTALLATION FILTER INSTALLATION AND DRAINAGE CONTROL PANEL OPERATION INSTRUCTIONS REMOTE CONTROL...

Page 3: ...tate moving Make sure not to use the wheels on thick carpet or to roll over objects as these could cause tipping Do not operate a unit that it has been dropped or damaged Do not place the portable air...

Page 4: ...Support for replacement parts compatible with your unit Turn off the product when not in use WARNING The appliance shall be stored in a room without continuously operating ignition sources for example...

Page 5: ...Your installation location should meet the following requirements Make sure that you install your unit on an even surface to minimize noise and vibration The unit must be installed near a grounded pl...

Page 6: ...icates the amount of heat it can remove from a room A higher Why is the cooling capacity lower on newer models than on older units number means more cooling power for a larger room Be sure you are com...

Page 7: ...it into the exhaust port of the rear panel and push the lock switch to lock the hose assembly firmly in place 2 Insert window panels B and C to each end of the main panel A with the exhaust port cut o...

Page 8: ...less than 70 Areas with more than 70 humidity the self evaporating function can still exhaust about 98 of the moisture and the remaining 2 of moisture will be collected in the water tank of the air c...

Page 9: ...SWING button to stop the louver at a desired angle LED Display Shows the set temperature in F or C and the Auto timer settings While on FAN modes it shows the room temperature Tank Full If the intern...

Page 10: ...be recirculated into the room If room temperature is higher than 77 F the fan speed can be adjusted If room temperature is lower than 77 F the fan speed is set at Low NOTE When using dehumidifying mo...

Page 11: ...F 95 F 16 C 35 C The compressor circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly This prevents over heating of the compressor and possible circuit breaker...

Page 12: ...oing so causes electrical danger DO NOT operate the portable air conditioner if the power supply was damaged during cleaning A damaged power cord must be replaced with a new cord Contact Whynter Custo...

Page 13: ...nal connection Please contact Whynter for service TIPS 1 Keep the exhaust hose as short and straight as possible The exhaust hose removes heat from the room It should remain as short and straight as p...

Page 14: ...ear the differ ence between high and low fan speed settings The air coming out of the unit is not very cold or the airflow volume is weak The filters are dirty or obstructed The air intake or exhaust...

Page 15: ...er surge low voltage defective household wiring or inadequate fuses Use in commercial or industrial applications Damage accidental or otherwise to the product while in the possession of a consumer not...