Tote Dispensing System
11
TROUBLESHOOTING
The following troubleshooting procedures will help you identify and correct problems with your system. Every part of the system has been designed per
your specifications and should not require maintenance, repair, or calibration beyond what was described in the maintenance section of this document.
If any of these troubleshooting procedures do not solve the issue, contact your supplier for additional support.
Issue
Steps to Resolve
WARNING!
ALWAYS ensure the main power supply is first locked out and the system depressurized before any service
is performed on this system. NEVER connect or disconnect lines, change filter elements, or undertake any
service work when this system is running or energized. SEVERE injury or death may occur.
The Tote Isolation Valves (located on the front of the tote) must be in the OPEN position when operating the
system and in the CLOSED position when servicing the system.
1. Check that tote shut off valve is in the proper position.
2. Check fittings for cracks and leaks.
3. Check the motor for correct rotation. If not, contact electrician.
4. Check the seals on the suction hose assembly. Replace if cracked or damaged.
5. Ensure that the Tote is vented.
1. Check electrical enclosure to ensure power is applied to the pump.
2. Check all circuit breakers to ensure power is available. Check the power cord from the
electrical enclosure to the motor for cracks or problems.
3. Check the power cord connector at the motor to ensure all the pins are seated correctly and
that the connector is clean of dirt and debris.
The motor stops working.
The Tote Dispensing System is not
dispensing correctly