Summary of Contents for Thermo Therapy TT-202

Page 1: ...ty of Industry CA 91744 0527 U S A 800 782 7706 626 968 6681 www whitehallmfg com Whitehall Manufacutring is a Member of Acorn Engineering s Family of Companies 6900 101 000 May 2009 Dry Heat Theraphy Models TT 101 TT 101L and TT 202 TT 101 TT 101L TT 202 ...

Page 2: ...d Care of Thermo Therapy Dry Heat Therapy 2 Introduction 3 TT 101 Product Information 4 TT 101L Product Information 5 TT 202 Product Information 6 Requirements for Installation 7 Receiving Instructions 7 Specifications 7 Symbol Instructions 8 Instructions for Use and Operating Controls 9 Maintenance of the Unit 9 Changing the Fuse 10 Troubleshooting Guide 11 TABLE OF CONTENTS ...

Page 3: ...TT 101 and TT 101L models Model TT 202 is floor mounted TT 202 has dual blowers and speed controls as well as dual top and rear treatment ports The unit has permanently installed rubber pads along the top to provide patient under arm comfort All Thermo Theraphy Units have an elevated top edge on 3 sides to best capture and prevent the spread of errant Celstim The controls located on the control pa...

Page 4: ... Thermo Therapy Dry Heat Therapy 4 Hospital Grade Plug Top Inlet Port with Velcro tightening sleeves Removable Rear Panel for Access to Treatment Cavity and Easy Celstim Removal Replaceable 15 AMP Fuses TT 101 ON OPTIONAL STAND CONTROL PANEL TT 101 Fresh Air Inlet and Filter Underneath Strong Rugged Housing Control Panel Tightening Sleeves Treatment Ports Complete with Removable Velcro ...

Page 5: ... 968 6681 Fax 626 855 4862 Web www whitehallmfg com Instructions for Operation and Care of Thermo Therapy Dry Heat Therapy 5 TT 101L ON OPTIONAL STAND CONTROL PANEL TT 101L Treatment Ports Complete with Removable Velcro Fresh Air Inlet and Filter Underneath Strong Rugged Housing Tightening Sleeves ...

Page 6: ... Thermo Therapy Dry Heat Therapy 6 TT 202 ON OPTIONAL STAND CONTROL PANEL TT 202 Top Treatment Ports Removable Upper Panel for Easy Celstim Removal Removable Panel for Access by Qualified Repair Personnel Top and Rear Treatment Ports with Removable Velcro Tightening Sleeves Air Intake and Filter Hospital Grade Plug Control Panel See Below Lower front storage compartment Locking Casters ...

Page 7: ...Therapy models are shipped complete with the proper amount of sterilized Celstim and as soon as they are carefully unpacked they are ready to go If shipping damage has occurred notify Whitehall Manufacturing immediately so a proper claim can be made and replacement or repair secured SPECIFICATIONS TT 101 the outside dimensions are 19 1 2 50 cm L x 16 1 2 41 cm H x 10 1 2 27 cm When placed on the o...

Page 8: ...y must be reviewed as with any heat modality for heat sensitivity and circulatory problems Again good ventilation should be considered and patients and operators sensitive to dust should with a mask and or the treatment ports and the extremity being treated could be covered with a damp towel Constant supervision is necessary when the unit is used with children invalids or any one who cannot safely...

Page 9: ...er wrench to remove the filter cover The housing can be cleaned with a mild household cleaner without damage as its surface is similar to that found on kitchen counters and cabinets The treatment port sleeves can be washed and replaced To remove the sleeves carefully pull the bottom of the rims toward the center away from the side and at the same time pull or push them up and out of the housing Th...

Page 10: ... holders at rear of the unit near cord Depress the Fuse holder caps with the use of a common blade screwdriver or fingers and rotate counterclockwise approximately 90 or until the cap becomes loose Remove the fuse holder cap exposing the glass fuse Remove the blown fuse Once the old fuse has been removed replace it with a new fuse of the same kind and amperage Re install the fuse holder cap by dep...

Page 11: ... Unit unplugged unit fuse s has blown electric outlet supply breaker has opened local GFCI or GFI has opened or the switch is faulty Check outlets GFCI otherwise call an electrical or qualified repair personnel Heat indicating light is not lit when power on and unit is heating Burned out indicator light Refer to qualified repair personnel Blower speed cannot be controlled or will not operate at fu...

Page 12: ... 968 6681 Fax 626 855 4862 Web www whitehallmfg com E mail info whitehallmfg com Whitehall Manufacturing is a Division of Acorn Engineering Company 6900 101 000 May 2009 Any questions regarding servicing of products in Europe or the Middle East should be directed to Niva Medical Company Olarinluoma 14 B FIN 02200 Espoo Finland Phone 358 9 615 00 540 Fax 358 9 615 00 545 Web www nivamedical fi E ma...