background image

GB

Installation

Disconnect the mains supply before installation

This fixture is to be installed and maintained by a recognised electrician.

Care must be taken when plastering the housing that no excess plaster is applied on the inside of the luminaire housing as this is detrimental to the 

operation of the luminaire.

1. Cut-out the required recessing aperture and screw fix the frame (A) to the soffit (as shown). Use a timber batten backing to the soffit if stronger fixing 

points are required.

2. Remove any insulation or obstruction within 150mm of the mounting frame.

3. Plaster the ceiling using the lip of the frame as a stop bead for the plaster finish.

4. Clean any excess plaster from inside the mounting frame as this will have detrimental effect on the operation of the luminaire.

Make the electrical connection as follows:

Fitting Type: P150SWW-LVC; P150RWW-LVC;

A. Remove the female 230/240v 50/60Hz 2-pin connector plug from the luminaire and wire the plug to the secondary side of the transformer. Refer to the 

transformer for a detailed wiring diagram. Use only Whitegoods supplied transformers.

B. Wire the mains input to the supplied transformer, refer to the transformer for a detailed wiring diagram.

C. Re-connect the female plug from the mains transformer to the male plug attached to the luminaire.

Fitting Type: P150SWW-MVC; P150RWW-MVC;

A. Unplug the female 230/240v 50/60Hz 3-pin connector from the lamp insert and wire the mains cable into position.

B. Re-connect the female to male plug.

Fitting Type: P150SWW-LED; P150RWW-LED; TBA.

Fitting Type: P150SWW-CDMTC; P150SWW-CDMTC; 

A. Unplug the female 230/240v 50/60Hz 2-pin plug from the lamp insert and wire the control gear secondary side to the plug. Refer to the control gear 

for a detailed wiring diagram. Use only Whitegoods supplied control gear.

B. Wire the mains input to the supplied transformer, refer to the transformer for a detailed wiring diagram.

C. Re-connect the female plug from the mains transformer to the male plug attached to the luminaire.

Fitting Type: P150SWW-CFL; P150RWW-CFL;

A. Wire the mains input to the supplied control gear, refer to the control gear for a detailed wiring diagram.

B. Connect the cable plug from the control gear to the luminaire insert.

5. Insert the specific lamp into the lamp insert as shown overleaf.

6. Clip the glass stirrup (C) onto the lamp cartridge (B) (The glass stirrup can be connected in a the flush or recessed position, dependant on lamp type)

7. Connect the security cable to the luminaire insert and ‘push-click’ the lamp insert assembly (B/C) into the frame (A)

Re-lamping Procedure

Disconnect the mains power supply before re-lamping

1. ‘Push-click’ the lamp cartridge assembly (B/C) to release from the frame (A)

2. Suspend the assembly on the security cable wire

3. Remove the glass stirrup (C)

4. Replace the lamp within the lamp insert (B), (dispose of lamp according to specific regulations)

5. Re-fit the glass stirrup to lamp insert (The glass stirrup can be connected in a flush or recessed position as described above)

6. ‘Push-click’ the lamp insert assembly (B/C) into the frame (A)

Reviews: