21
Menu #
(Hold Menu 8 Seconds)
Description
Default Setting
(flashing icons)
Settings
(
Press or )
32
Aux Cycle Rate:
how often the
auxiliary heat will turn on
MEd
SLO – slow
MEd – medium
FAS – fast
35
Cool Cycle Rate:
how often
the cooling will turn on
MEd
SLO – slow
MEd – medium
FAS – fast
50
Compressor Lockout:
protects the compressor
from short cycling
OFF
On
– 5 minute delay
OFF
– no delay
65
Max Heat Limit:
maximum set
point for heat mode
99
47 to 99
66
Minimum Cool Limit:
minimum set
point for cool mode
45
45 to 97
* Setting the reversing valve to “O” or “B” is necessary for heat pump systems only. Please refer to the chart in
section 3.3 for your old thermostat’s wiring.
On your OLD thermostat
• if you had a wire connected to “O” terminal, set reversing valve (menu # 20) valve as “O” at this step.
• if you had a wire connected to “B” terminal (and at the same time, no wire was connected to “O”), set reversing
valve as “B” at this step
• if you had a wire connected to “O/B” terminal, please call Customer Support at 877.654.9394.