White Rodgers UNIVERSAL INTEGRATED FURANCE CONTROL 50A65-843 Installation Instructions Manual Download Page 4

4

TH

TR

MV

MV

GND

FP

RO1

RO2

HLO

HLI

PS

C

R

G

W

Y

EAC N

E33

HUM N

XFMR N

LINE N

CIR N

IGN N

IND N

IGN

IND

HUM

EAC

XFMR

LINE

PARK

PARK

HEAT

COOL

IGNITOR

Y

W

G

R

THERMOSTAT

GAS

VALVE

HIGH LIMIT

(N. C.)

AUX. HIGH

LIMIT (N. C.)

PRESSURE SWITCH (N. O.)

FLAME

SENSOR

PROBE

COMPRESSOR

CONTACTOR

ELECTRONIC

AIR CLEANER

HUMIDIFIER

INDUCER

CIRCU-
LATOR

BLOWER

50A65-843

24 VAC

120 VAC

24 VAC CLASS II

TRANSFORMER

HOT

(LINE)

NEUTRAL

(LINE)

TH

TR

Low Voltage (24 VAC)

Line Voltage (120 VAC)

LEGEND

N. C. = Normally closed switch
N. O. = Normally open switch

TYPICAL SYSTEM WIRING DIAGRAM

Summary of Contents for UNIVERSAL INTEGRATED FURANCE CONTROL 50A65-843

Page 1: ...flame sensing element initiate automatic ignition of the burner sensing of the flame and system shut off during normal operation These controls incorporate system fault analysis for quick gas flow sh...

Page 2: ...ponse Time 2 0 sec At 50 Hz all timing specifications should be increased by 20 Gases Approved Natural Manufactured Mixed Liquified Petroleum and LP Gas Air Mixtures are all approved for use TIMING SP...

Page 3: ...lowappliancemanufacturer s recommended installation or service instructions to ensure proper operation The 50A65 has only one serviceable part an automotive type fuse which protects the low voltage tr...

Page 4: ...S VALVE HIGH LIMIT N C AUX HIGH LIMIT N C PRESSURE SWITCH N O FLAME SENSOR PROBE COMPRESSOR CONTACTOR ELECTRONIC AIR CLEANER HUMIDIFIER INDUCER CIRCU LATOR BLOWER 50A65 843 24 VAC 120 VAC 24 VAC CLASS...

Page 5: ...ent low voltage thermostat Y terminal or equivalent 2nd wire from Y terminal goes to 24 VAC HOT side of compressor contactor coil 24 VAC COMMON side of compressor contactor coil gas valve both gas sol...

Page 6: ...delay to fan off period ends the circulator fan and electronic air cleaner are de energized If flame is not detected both valves are de energized the ignitor is turned off and the 50A65 control goes i...

Page 7: ...TURES The 50A65 843 control continuously monitors its own operation and the operation of the system If a failure occurs the LED will indicate a failure code as shown below If the failure is internal t...

Page 8: ...MOUNTING HOLE TEMPLATE FOR MOUNTING HOLE LOCATIONS 4 172 007 2 plcs 6 402 010 2 plcs Refer to page 3 of the installation instructions for proper installation MOUNTING HOLE TEMPLATE...

Reviews: