White Rodgers Electro-Air 10C27S-010 Owner'S Manual Download Page 4

4

PREINSTALLATION

tions. Turn cells upside down (with the same end facing
the cabinet opening). This will locate the ionizing wires at
the right, and both contact buttons and cell handles will be
facing the power door. Air flow direction must agree with
arrow embossed on end of collecting cells.

After installing the cell sections, install pre-filters in cabi-
net tracks on the right. This will again place the pre-filters
on the air entering side (on the same side as ionizing
wires).

LOCATING THE AIR FILTER

Your air filter must be mounted in the return air duct of a
central forced-air system, on the air entering side of your
furnace. (See Figure 3 for example.)

Select a location that meets the following:

1.

The face of the cell will be at a right angle to the air
stream.

2.

Allow the following clearances to permit removal of
cells and pre-filters: (See Figures 4 and 5)

Model 10C27S-010 - 14 inches
Model 14C27S-010 - 15 inches
Model 16C27S-010 - 14 inches
Model 20C27S-010 - 15 inches

For complete dimension data refer to Figure 5.

3.

The air filter is not to be placed in the discharge of
either the heating or cooling unit.

4.

IMPORTANT:  If atomizing spray type humidifier is
used, it must be installed downstream from the air
filter.

If your furnace duct system has a pre-installed boot,
discard front cover of boot and slide the air cleaner
component inside the boot. (Applies to 14C27S-010 and
20C27S-010.)

If furnace opening cannot be enlarged to required size, a
transition sheet metal section must be used. Transition
must be planned for each job. Reduction should not be
more than 4 inches per linear foot, approximately 20
angular degrees (Figure 3).

DIRECTION OF AIR FLOW THROUGH THE

AIR CLEANER

Your air cleaner is shipped from the factory with air flow
from left-to-right. If this air flow is suitable for the installa-
tion, no further changes need to be made (Figure 4). For
right-to-left air flow, remove both pre-filter and cell sec-

Air Flow

Furnace
Opening

Not to Exceed 20

°

Air Flow

Electronic
Air Cleaner
Opening

Electronic
Air Cleaner

Furnace

Transition Section

(if Needed)

Figure 3

Cabinet

(Interchangeable)

Collecting Cell

(Interchangeable)

Collecting Cell

Outlet Box

Power Pack

Handle

Contact

Button

Contact

Button

Pre-Filters

(Interchangeable)

See text for Cell

Removal Clearance

Figure 4

6 7/8"

A

B

E

D

F

C

Knockouts for

3/4" Conduit

(three sides)

10C27S-010

24 3/4

21 5/16 18 5/8 13 9/16 16 7/16 19 1/16

14C27S-010 29 11/16 26 1/4

23 5/8 13 9/16 16 7/16 19 1/16

16C27S-010

25 1/2

21 5/16 18 5/8

17 3/4

20 5/8

23 3/8

20C27S-010 29 11/16 26 1/4

23 5/8

17 3/4

20 5/8

23 3/8

MODEL NO.

A

B

C

D

E

F

Figure 5

Summary of Contents for Electro-Air 10C27S-010

Page 1: ...Service Guide Technical Repair Guide Repair Parts Part No 37 6123D Replaces 37 6123C 0032 Electronic Air Cleaner Printed In U S A UL Listed CSA Certified by White Rodgers Please read and familiarize y...

Page 2: ...it must comply with local electric codes or other applicable codes Review and understand local codes prior to in stallation Failure to do so could result in serious personal injury or death CAUTION CA...

Page 3: ...easy to operate and maintain Its basic components and their functions are as follows See Figure 2 Cabinet mounts to existing duct work and houses the collecting cells and pre filters Collecting Cells...

Page 4: ...ream from the air filter If your furnace duct system has a pre installed boot discard front cover of boot and slide the air cleaner component inside the boot Applies to 14C27S 010 and 20C27S 010 If fu...

Page 5: ...t offset to match air filter opening If duct connection to furnace allows less than nine inches for mounting the air cleaner shorten the lateral trunk or attach an offset fitting to the elbow HORIZONT...

Page 6: ...attached directly Figure 13 or a starting collar can first be fitted to the furnace inlet A butt or slip joint can be used Securely attach the cabinet to furnace inlet using at least two of the mount...

Page 7: ...t electrical connections to the air cleaner are installed properly see Figure 17 The air cleaner should not have power unless the furnace blower is on Floor Conduit Duct Electronic Air Cleaner Figure...

Page 8: ...r service problems see Basic SST UST Service Guide Operating Light On Off Switch 9 Remove junction box cover and install the required bushing into the 3 4 in Knock out With the supply voltage turned o...

Page 9: ...nd rinse thoroughly with clean water 6 Allow cell s and pre filter s to drip dry for a mini mum of 2 hours Cell s and pre filter s may be tipped at a slight angle to expedite the drip dry pro cess 7 R...

Page 10: ...loose ionizing wire s cracked insulator s etc 3 Collecting cells dirty A Clean cells as instructed in this manual 4 Faulty power supply see power supply checkout procedure BASIC SST UST SERVICE GUIDE...

Page 11: ...el in locating and correcting any malfunction that might occur to render the air cleaner ineffective or inop erative The air cleaner has been designed with replace able components such as the high vol...

Page 12: ...tact 4 Using an extension cord apply 240 VAC to power pack Turn power switch to ON position 5 Connect meter negative lead to metal frame of collecting cell Use high voltage probe to measure voltage at...

Page 13: ...13 NOTES...

Page 14: ...14 14 REPAIR PARTS...

Page 15: ...F844 0131 11 Switch F876 0202 F876 0202 F876 0202 F876 0202 12 Power Pack Cabinet Only N A N A N A N A 13 Connector Male F827 0017 F827 0017 F827 0017 F827 0017 14 Power Supply F858 0975 F858 0975 F8...

Page 16: ...a White Rodgers Electronic Air Cleaner or product containing a White Rodgers Electronic Air Cleaner Although White Rodgers does not extend a warranty directly to consumers White Rodgers does extend a...

Reviews: