White Rodgers Comfort Plus ACB1000 Owner'S Manual Download Page 2

2

INTRODUCTION

The White-Rodgers Air Cleaner Compartment comes com-
plete with a 5

 media furnace air filter. This filter must be

changed every three months to maintain efficiency of the filter
and furnace system. For maximum efficiency, the compart-
ment can be upgraded to a White-Rodgers Electronic Air
Cleaner.

Please read instructions before installing and using the Air
Filter Compartment.

Before installing or servicing, always
shut off electricity. This will prevent
any electrical shocks.

!

WARNING

!

WARNING

Do not attempt installation of this unit unless you
are familiar with the necessary tools, equipment,
and potential hazards.

Installation should be performed only by a qualified
service provider.

Failure to do so could result in reduced performance
of the unit, serious personal injury or death.

!

WARNING

Installation of this unit must comply with local
electric codes or other applicable codes.

Review and understand local codes prior to
installation.

White-Rodgers will not assume any responsibility for
component failures due to incorrect installation procedures.

TABLE OF CONTENTS

Rules for Safe Installation and Operation ............ 2

How the Air Filter Works ...................................... 3

Construction of the Air Filter Compartment ......... 3

Preinstallation ....................................................... 4

Installation ............................................................ 6

Maintenance ......................................................... 7

Repair and Upgrade Parts ................................... 7

GUARANTEE

1. Read the Owners Manual and the Rules for Safe

Operation carefully. Failure to follow these rules and
instructions could cause a malfunction of filter or
unsatisfactory service.

RULES FOR SAFE INSTALLATION

AND OPERATION

2. Follow a regular service and maintenance schedule

for efficient operation.

!

CAUTION

The fiber filter used in this cabinet for air cleaning
must be replaced every 90 days. Your heating and
cooling efficiency will decrease due to insufficient
air flow when filter becomes dirty.

DID YOU GET THE RIGHT SIZE

AIR FILTER COMPARTMENT

Model ACB & ACM1000 

are designed for heating or

cooling blowers delivering 600 to 1200 cubic feet of air per
minute (cfm.)

Model ACM1200TM 

is designed for heating or cooling

blowers delivering 1000 to 1600 cfm.

Model ACB & ACM1400 

are designed for heating or

cooling blowers delivering 1000 to 1600 cfm.

Model ACB & ACM1600 

are designed for heating or

cooling blowers delivering 1200 to 1800 cfm.

Model ACB, ACM2000 & ACM2000X 

are designed for

heating or cooling blowers delivering 1600 to 2200 cfm.

Model ACM2000U 

is designed for heating or cooling

blowers delivering 1600 to 2200 cfm. with insulation on
door and universal rail.

Before installing the filter, make sure you have selected
the proper size unit for your heating and cooling system
requirements. See specifications on page 4.

BASIC TOOLS REQUIRED

Tin Snip

Screwdriver

Rule or Tape Measure

Drill

Summary of Contents for Comfort Plus ACB1000

Page 1: ...el Number ACM ACB OWNER S MANUAL Installation Operation Technical Repair Guide Repair and Upgrade Parts PART NO 37 6383C Replaces 37 6383B 0446 Please read and familiarize yourself with the contents o...

Page 2: ...ntenance 7 Repair and Upgrade Parts 7 GUARANTEE 1 Read the Owners Manual and the Rules for Safe Operation carefully Failure to follow these rules and instructions could cause a malfunction of filter o...

Page 3: ...also easy to maintain Its basic components and their functions are as follows See Figure 2 Air Filter Compartment mounts to existing duct work and houses the filters or optional electronic air cleaner...

Page 4: ...The air filter is not to be placed in the discharge of either the heating or cooling unit 4 IMPORTANT If atomizing spray type humidifier is used it must be installed downstream from the air filter If...

Page 5: ...ove furnace HIGHBOY FURNACE Figure 7 Side installation Filter is mounted vertically where return air enters side inlet of furnace OFFSET INSTALLATION Figure 9 Typical use of duct offset to match air f...

Page 6: ...ment to furnace inlet using at least two of the mounting holes on each side of the compartment 4 Using butt joint attach duct work normally an elbow to the upstream side of air filter compartment Note...

Page 7: ...ive the following information as shown in this list 1 The PART NUMBER 2 The PART DESCRIPTION 3 The MODEL NUMBER of the Air Filter Compart ment Always order by PART NUMBER Not by ITEM NUMBER PARTS LIST...

Page 8: ...does not extend a warranty directly to consumers White Rodgers does extend a warranty to Wholesalers and Original Equipment Manufacturers who use White Rodgers Products To obtain more information abo...

Page 9: ...Mod le ACM ACB GUIDE DE L UTILISATEUR Installation Exploitation Guide technique de r paration Pi ces de rechange et de mise niveau PI CE No 37 6383C Remplace 37 6383B 0446 Pri re de lire attentivemen...

Page 10: ...l purateur risquerait de fonctionner incorrectement ou pas du tout DIRECTIVES D INSTALLATION ET D EXPLOITATION S CURITAIRES 2 Effectuer r guli rement les r visions et l entretien afin d assurer un fon...

Page 11: ...cellules d purateur lectronique facultatives REMARQUE Pour transformer l purateur en appa reil lectronique efficacit lev e utiliser l ensemble de mise niveau ACR qui convient D tails la page 7 Filtre...

Page 12: ...NT Si un humidificateur pulv risation est utilis il doit tre install en aval de l purateur S il est impossible d agrandir suffisamment l ouverture du g n rateur d air chaud on doit alors installer une...

Page 13: ...r G N RATEUR CAISSONS SUPERPOS S figure 7 Installation lat rale Installer l purateur la verticale l o la reprise d air p n tre dans la prise d air lat rale du g n rateur INSTALLATION AVEC D VIATION fi...

Page 14: ...du bo tier 4 Assembler en bout le conduit de reprise d air habituelle ment une section coud e et la face en amont du bo tier de l purateur Noter dans le coude l utilisation d aubes re courb es en t l...

Page 15: ...der de la fa on suivante ATTEN TION Il est important de remplacer tous les 90 jours le filtre fibres install dans le bo tier Lorsque le filtre est sale les installations de chauffage et de climatisat...

Page 16: ...t ge directement les consommateurs Cependant l entreprise garantit ses produits aupr s des grossistes et des fabricants qui les utilisent Pour savoir comment cette garantie peut vous avantager nous vo...

Reviews: