White Rodgers 1F97-0671 Installation And Operating Instructions Manual Download Page 9

9

PROGRAMMING

Energy Saving Factory Pre-Program

The 1F97-0671

 

thermostat is programmed with the energy saving settings shown in the table below for all days of the week. If 

this program suits your needs, simply set the thermostat clock and press the RunSched button.
The table below shows the factory set heating and cooling schedule for all days of the week.

* You can eliminate these two program periods in the confi guration menu (reference #15) if the building is occupied all day. 
  Day period will change to 6:00 AM and 70° and can be programmed as required.

* Wake Up

(Morn)

Leave For Work

(Day)

* Return Home

(Eve)

Go To  Bed 

 (Night)

Heating

Program

6:00 AM

70°F

8:00 AM

62°F

5:00 PM

70°F

10:00 PM

62°F

Cooling

Program

6:00 AM

75°F

8:00 AM

83°F

5:00 PM

75°F

10:00 PM

78°F

Planning Your Program – Important

The Heating and Cooling Program schedules below allow you to pencil in your own program times and temperatures.
The 1F97-0671 comes confi gured for 7 day programming and can also be confi gured for 5+1+1 programming (see confi gura-
tion section).

Factory settings are listed on Monday, Saturday and Sunday. If you are re-programming a 5+1+1 day schedule, pencil in your 
own times and temperatures directly below the factory times and temperatures.

If you are re-programming a 7 day schedule, fi ll in all lines with the times and temperatures you want.

Keep the following guidelines in mind when planning your program.
•  In Heating, lower temperatures will save energy.
•  In Cooling, higher temperatures will save energy.

•  If you plan on using Auto Changeover, do not program the heating temperature higher than the cooling temperature.

Worksheet for Re-Programming 5+1+1 and 7 Day Program

Heating

Program

Wake Up

(Morn)

Fan

Leave For Work

(Day)

Fan

 Return Home

(Eve)

Fan

Go To  Bed 

 (Night)

Fan

MON

6:00 AM

70°F

Auto 8:00 AM

62°F

Auto 5:00 PM

70°F

Auto 10:00 PM

62°F

Auto

TUE

WED

THU

FRI

SAT

6:00 AM

70°F

Auto 8:00 AM

62°F

Auto 5:00 PM

70°F

Auto 10:00 PM

62°F

Auto

SUN

6:00 AM

70°F

Auto 8:00 AM

62°F

Auto 5:00 PM

70°F

Auto 10:00 PM

62°F

Auto

Cooling

Program

Wake Up

(Morn)

Fan

Leave For Work

(Day)

Fan

 Return Home

(Eve)

Fan

Go To  Bed 

 (Night)

Fan

MON

6:00 AM

75°F

Auto 8:00 AM

83°F

Auto 5:00 PM

75°F

Auto 10:00 PM

78°F

Auto

TUE

WED

THU

FRI

SAT

6:00 AM

75°F

Auto 8:00 AM

83°F

Auto 5:00 PM

75°F

Auto 10:00 PM

78°F

Auto

SUN

6:00 AM

75°F

Auto 8:00 AM

83°F

Auto 5:00 PM

75°F

Auto 10:00 PM

78°F

Auto

Summary of Contents for 1F97-0671

Page 1: ...ture Sensor Indoor or Outdoor Yes ATTENTION MERCURY NOTICE This product does not contain mercury However this prod uct may replace a product that contains mercury Mercury and products containing mercu...

Page 2: ...ng Power Stealing Switches The Power Stealing Switches Fig 1 should be left in the On position for most systems The information in the following table details the thermostat power method and switch op...

Page 3: ...system wiring information This thermostat is designed to operate a single transformer or two transformer system This thermostat is configured for use with the following fossil fuel systems SINGLE STAG...

Page 4: ...u 8 Displays Save when Cool SavingsTM is working 9 Displays Hold in programmable mode when not in Hold mode Displays Light Bulb in non programmable mode 10 Initially displays Auto Sched If Auto Schedu...

Page 5: ...MENU 0 current temperature 1 HI 2 HI 3HI 4 HI 1 LO 2 LO 3 LO 4 LO Adjustable Ambient Temperature Display 10 MENU F C Selects Fahrenheit Celsius Temperature Display 11 MENU On b OFF May select Beeper O...

Page 6: ...E To change cycle rate press the or button Cycle rate differentials for different settings are MODE Fast Medium Slow FA ME SL Heat SS1 MS2 0 4 F 0 6 F 1 7 F Cool SS1 MS2 0 9 F 1 2 F 1 7 F 6 Select Com...

Page 7: ...tton to advance Return to this point when you are ready to start your selected lock out and continue by Press Display will read 001 Pressing or buttons to select your keypad lock out combination numbe...

Page 8: ...ntire period The Prog Fan On can be overridden to have the fan cycle with the system Press the FAN but ton to change the fan to Auto The fan programming will be overridden until the next program perio...

Page 9: ...day and Sunday If you are re programming a 5 1 1 day schedule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a 7 day schedule fil...

Page 10: ...and repeat steps 2 through 5 7 Press RunSched to return to normal operation Fill in the blank schedule on the previous page then Enter the Heating Program 1 Press SYSTEM button to select Heat in the s...

Page 11: ...perature will be Remote for indoor sensor or Outdoor Remote for outdoor sensor If the remote sensor is an indoor sensor and the local display has been disabled the temperature displayed as the room te...

Page 12: ...the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat Thermostat Setting...

Reviews: