White Rodgers 1F97-0671 Installation And Operating Instructions Manual Download Page 7

7

INSTALLER/CONFIGURATION MENU

temperature and press 

Auto Schedule

. This value will be 

copied into all the morning, day and evening program  
periods. The night program periods will have a 6°F set back.

16) 

Select Remote Temperature Sensor

 – This control 

allows one wired remote temperature sensor (indoor, 
F145-1328, or outdoor, F145-1378) be connected to it and 
indicates the measured temperature in clock digits. This 
menu enables you to select the remote sensor and also 
confi gure it as indoor or outdoor temperature sensor. Fac-
tory default is off. Select 

Remote On

 and 

Remote in

 (for 

indoor) or 

Outdoor Remote

.

 

Local Temperature Sensor disable

 – This is applicable 

only when indoor remote temperature sensor is enabled. 
Factory default is 

Loc On

. You can make it 

Loc Off

 if you 

desire by using 

 or 

 buttons. Then, only the indoor 

remote temperature reading will be used for control

17) 

Select Daylight Saving Time Calculation

 – This feature 

will allow the thermostat to calculate the DST automati-
cally and apply it to the Real Time Clock display. Default 
On. Use 

 or 

 touch keys to select the feature OFF.

18) 

Keypad Lockout

 – This step allows you to select the type 

of lockout or limited range security required. If no lock-
out or limited range security is required, press MENU to 
advance the menu.

 

Three security settings are available in this menu item. 
Use the 

 or 

 buttons to select the lockout desired. 

 

Lockout selections are:

 

"Keypad Lockout 

and 

L"

 

Total Lockout. Total Lockout 

locks all keys.

 

"Keypad Lockout and P"

 = Partial Lockout. Partial Lock-

out allows only the 

 or 

 buttons to operate within 

your set temperature limits.

 

"Keypad Lockout and Limit"

 prevents changing the 

temperature limits in the Confi guration Menu.

 

Press Menu after selecting the type of lockout.

 

"Keypad Lockout Combination Number Selection" 

 

Display will read 

"000" "Keypad Lockout"

. Note: 

"000" 

is 

not a valid combination choice.  

 

Skip this step and continue through the remaining confi gu-
ration menu items if you require an Air Filter Change out 
indicator or Humidifi er Pad Change out indicator by press-
ing the MENU button to advance.

 

Return to this point when you are ready to start your 
selected lock-out and continue by:

 Press  . Display will read 

"001"

.

 Pressing   or 

 buttons to select your keypad lock-

out combination number. 

 

Record the number you select for future use.

 

Press MENU or RunSched to exit the menu. The security 
feature you select will start. The system button will remain 
active for 10 seconds to allow setting Heat, Off, Cool or 
Auto.

19) 

Limited Heat Range – 

This feature provides a maximum 

setpoint temperature for heat. The default setting is 99°F. It 
can be changed between 62°F and 98°F by pressing the 

 or 

 button.

20) 

Limited Cool Range

 – This feature provide a minimum 

setpoint temperature for cool. The default setting is 45°F. It 
can be changed between 46°F and 82°F by pressing the 

 or 

 button. 

21) 

Select Filter Replacement Reminder and Set Run Time 

Select the 

"Change Filter" 

reminder On or OFF. If se-

lected On, press 

MENU 

to select the time period from 25 

to 1975 hours in 25 hours increments. In a typical system, 
200 hours (default) of run time is approximately 30 days. 
After the selected time of blower operation, the thermostat 
will display 

"Change Filter" 

as a reminder to change or 

clean your air fi lter. When 

"Change Filter" 

is displayed, 

press 

MENU 

or 

RUN SCHED 

button to clear the display 

and restart the time to the next fi lter change.

 

22) 

Change UV Lamp

 – This feature allows the thermostat to 

display the words 

"Change UV Lamp" 

(Call for Service 

of UV bulb) after a set time of UV bulb operation. This is 
a reminder to maintain your UV system at optimum level 
of operation. When enabled the factory set interval for 

"Change UV Lamp" 

to be displayed is 350 days of UV 

bulb operation and can be adjusted in 25 day increments. 
This should be adjusted with respect to the bulb's recom-
mended maintenance schedule.

 When 

"Change UV Lamp"

 is displayed, you can clear it 

by pressing MENU.

23) 

Select Reversing Valve Output

 – The O/B option is 

factory set at "O" position. This will accommodate the 
majority of heat pump applications, which require the 
changeover relay to be energized in COOL. If the thermo-
stat you are replacing or the heat pump being installed 
with this thermostat requires a "B" terminal, to energize 
the changeover relay in HEAT, the O/B option should be 
set at "B" position.

Summary of Contents for 1F97-0671

Page 1: ...ture Sensor Indoor or Outdoor Yes ATTENTION MERCURY NOTICE This product does not contain mercury However this prod uct may replace a product that contains mercury Mercury and products containing mercu...

Page 2: ...ng Power Stealing Switches The Power Stealing Switches Fig 1 should be left in the On position for most systems The information in the following table details the thermostat power method and switch op...

Page 3: ...system wiring information This thermostat is designed to operate a single transformer or two transformer system This thermostat is configured for use with the following fossil fuel systems SINGLE STAG...

Page 4: ...u 8 Displays Save when Cool SavingsTM is working 9 Displays Hold in programmable mode when not in Hold mode Displays Light Bulb in non programmable mode 10 Initially displays Auto Sched If Auto Schedu...

Page 5: ...MENU 0 current temperature 1 HI 2 HI 3HI 4 HI 1 LO 2 LO 3 LO 4 LO Adjustable Ambient Temperature Display 10 MENU F C Selects Fahrenheit Celsius Temperature Display 11 MENU On b OFF May select Beeper O...

Page 6: ...E To change cycle rate press the or button Cycle rate differentials for different settings are MODE Fast Medium Slow FA ME SL Heat SS1 MS2 0 4 F 0 6 F 1 7 F Cool SS1 MS2 0 9 F 1 2 F 1 7 F 6 Select Com...

Page 7: ...tton to advance Return to this point when you are ready to start your selected lock out and continue by Press Display will read 001 Pressing or buttons to select your keypad lock out combination numbe...

Page 8: ...ntire period The Prog Fan On can be overridden to have the fan cycle with the system Press the FAN but ton to change the fan to Auto The fan programming will be overridden until the next program perio...

Page 9: ...day and Sunday If you are re programming a 5 1 1 day schedule pencil in your own times and temperatures directly below the factory times and temperatures If you are re programming a 7 day schedule fil...

Page 10: ...and repeat steps 2 through 5 7 Press RunSched to return to normal operation Fill in the blank schedule on the previous page then Enter the Heating Program 1 Press SYSTEM button to select Heat in the s...

Page 11: ...perature will be Remote for indoor sensor or Outdoor Remote for outdoor sensor If the remote sensor is an indoor sensor and the local display has been disabled the temperature displayed as the room te...

Page 12: ...the manufacturer of your system or service person can instruct you on how to test the Heat Cool system for correct operation If the system operates correctly replace the thermostat Thermostat Setting...