background image

Page 7

22994-0-1106

Locating Firebox

Place firebox in framing opening. Use the four (4) framing brackets 

provided on the firebox to attach firebox to framing. Different hole 

locations can be used for finishing materials with thicknesses of 

3/8", 1/2" and 3/4". Attach these materials with screws provided, 

two (2) per framing bracket. 

See Figure 7.

Framing brackets should fit directly against framing material. Use 

at least one (1) nail per bracket to secure in place.
Check squareness of the firebox prior to securing to framed opening. 

See Figure 8.

Figure 7

A black hood that is furnished with each firebox (or optional hood) 

MUST be installed before the firebox is used. Failure to do so may 

create a possible fire hazard. The hood is located inside the firebox 

on flush face units. If brass, stainless steel, or hammered pewter 

hoods are desired, they can be purchased as an option. Attachment 

is the same as the standard black hood.

Flush Face Models

1. On flush face models, loosen the two screws (A) holding firebox 

top to face panel, then slide the hood flange between the firebox 

top and face panel and re-tighten the screws.

2. Install one (1) screw at each end of the hood as shown (C).

A

C

A

C

Louvered Models

Flush Face Models

Figure 9

FIREBOX OPENING

CHECK TO SEE

THAT BOX IS SQUARE

PRIOR TO ATTACHING TO

FRAMING

Figure 8

FIREBOX INSTALLATION INSTRUCTIONS (continued)

INSTALLING HOOD

Summary of Contents for VFS32FB2DF-1

Page 1: ...alified installer service agency or the gas supplier Carefully review the instructions supplied with the decora tive type unvented room heater for the minimum fireplace size requirement DO NOT INSTALL A VENT FREE LOG SET IN THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION GAS FIRED ANSI Z21 91 Ventless Fireplace Enclosures for Gas Fired Dec orative Type Unv...

Page 2: ...irebox Installation Instructions 4 7 Installing Hood 7 8 Gas Line Connection 8 Optional Single Speed Blower Installation Instructions 9 11 Junction Box Wiring Installation Instructions 12 Maintenance 12 Parts List 13 Parts View 14 How to Order Repair Parts 14 Accessories 15 16 TABLE OF CONTENTS ...

Page 3: ...al of such component part or accessory Any such action may create a possible fire hazard Consult your local building codes Firebox Screen The firebox screen must be in place when the firebox is operating Instructions to Installer 1 Installer must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with firebox 3 Installer should sh...

Page 4: ... of the firebox is 2 Leave at least 36 clearance from the front of the firebox Any vent free Gas Log Heater must be For use with approved ANSI Z21 11 2 unvented room heater Follow and complete the installation instructions of the gas log set and the requirements of this firebox Check all fittings for leaks before lighting the gas log set In planning the installation for the firebox it is necessary to d...

Page 5: ...tible or non combustible surface 2 A raised platform of combustible or non combustible material 3 Recessed into the floor as illustrated by Figure 4 4 Supported under all 4 corners of the firebox so that contact is made on all four perimeter edges on the bottom of the unit Example Four 4 concrete masonry blocks If the firebox is installed directly on carpeting tile or other combustible material othe...

Page 6: ...ed SELECT REFERENCE LETTER FLUSH VFS32 VFS36 VFS42 A 41 1 8 41 1 8 41 1 8 B 34 1 2 39 1 2 43 1 2 C 23 7 16 23 7 16 23 7 16 D 26 3 8 31 3 8 35 3 8 E 38 1 2 38 1 2 38 1 2 F 31 36 40 G 31 3 4 31 3 4 31 3 4 H 2 1 8 2 1 8 2 1 8 I 34 34 34 J 4 1 4 4 1 4 4 1 4 K 7 5 8 7 5 8 7 5 8 L 36 1 2 39 1 16 41 1 16 M 73 1 16 78 1 16 82 1 16 ...

Page 7: ...h each firebox or optional hood MUST be installed before the firebox is used Failure to do so may create a possible fire hazard The hood is located inside the firebox on flush face units If brass stainless steel or hammered pewter hoods are desired they can be purchased as an option Attachment is the same as the standard black hood Flush Face Models 1 On flush face models loosen the two screws A holding...

Page 8: ... pressure to a maximum of 14 w c This is in addition to the regulator fitted to the log set WARNING CONNECTION DIRECTLY TO AN UNREGULATED L P TANK CAN CAUSE EXPLOSION Install only a ANSI Z21 11 2 vent free log set into this firebox Figure 10 Extended Hoods If your non combustible facing material is over 1 in thickness that will be used to finish this firebox an extended hood is available that will ext...

Page 9: ...lation of the wiring be performed by a qualified electrician See Figure 12 1 If installed turn OFF gas supply to firebox gas log 2 If applicable turn OFF electric supply to firebox CAUTION ALL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH ALL LOCAL CITY AND STATE BUILDING CODES BEFORE MAKING THE ELECTRI CAL CONNECTION MAKE SURE THAT MAIN POWER SUPPLY IS DISCONNECTED...

Page 10: ...al Attach this terminal to the open terminal on the blower power cord See Figure 19 Connection B 10 Route the wires away from moving parts of the blower as sembly and retain wires together near the blower motor using the plastic purse clip provided 11 To complete the installation plug the power cord into the junction box receptacle at the right rear corner of the firebox outer wrap See Figure 17 12...

Page 11: ... a dirty blower wheel Remove fan and clean blower wheels Warning Unplugging of blower accessory will not stop the heater from cycling To turn off gas to the heater millivolt model push in gas control knob slightly and turn clockwise to OFF Do not force To turn off gas on direct ignition model turn gas line valve to OFF 1 FBB5 BLOWER ASSEMBLY COMPLETE 2 R8199 FAN CONTROL SWITCH 1 2 A B 110 VOLT AC ...

Page 12: ...on box Install a ULlisted cable clamp not supplied in the knockout hole Leave approximately 6 of wire in the junction box for connection Attach black wire to one side of the receptacle and white wire to opposite side of receptacle The ground wire should be attached to the green neutral screw Install the receptacle into the junction box Attach cover plate Keep the control compartment logs and burne...

Page 13: ...ACKET 3 17162 17162 JUNCTION BOX ASSEMBLY 4 R3492 R3492 RECEPTICLE 5 R3491 R3491 COVER JUNCTION BOX 6 19945 19945 BRACKET TOP BRICK RETAINER 7 R8670 R8670 BRICK PANEL RIGHT 8 BRICK PANEL BACK 9 BRICK PANEL LEFT 10 20145 20145 HOOD 11 R7052 R7052 ROD SCREEN 12 R8202 R8202 SCREEN CURTAIN 13 19401 19401 BRACKET BOTTOM BRICK RETAINER ITEM VFS42FB2ML VFS42FB3MF DESCRIPTION 1 17247 17247 TOP STANDOFF 2 ...

Page 14: ...er from the name plate on your equipment Then determine the Part Number not the Index Number and the Description of each part from the following appropriate illustration and list Be sure to give all this information Firebox Model Number Part Description Firebox Serial Number Part Number Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local har...

Page 15: ...use with FBB5 blower SCV 1 Frame Kits Standard 3 Piece Frame Kits Black Brass Stainless Steel or Hammered Pewter Extruded Aluminum Frame Kits Black Brass Stainless Steel or Hammered Pewter Contact dealer for all available optional frame kits Standard Hood Brass hood BR Stainless Steel SS Hammered Pewter HP Contact dealer for all available optional hood accessories ACCESSORIES ...

Page 16: ...ealer for all available optional trim accessories Decorative Door Kits Available as optional kits in Black Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for all available optional frame kit accessories Decorative Frame Kits Available as optional kits in Black Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for all available optional decorative door kit accesso...

Reviews: