INSTALLING OPTIONAL BLOWER
1. Remove bottom louver.
2. Remove upper louver.
3. Remove screen front by lifting upward on screen front.
4. Remove rear log support from inner casing [3 three (3)
10 x 1/2" screws]. See Figure 21.
5. Remove burner assembly [four (4) 10 x 1/2" screws]. See
Figure 22.
6. Remove two (2) 10 x 1/2" screws on the left side of the firebox
bottom. See Figure 23.
FBB6 for Unvented Gas Fireplace Models VFP24FP2 Series & VFP24FP3 Series
7. Insert blower assembly in left side of outer casing. Motor with
wiring will be to the inside of the outer casing, blower chute
will be facing upward. See Figure 24.
8. Push blower assembly against the left wall of the outer casing.
The magnets installed on the bottom of the bracket will hold
it in place.
9. Replace the two (2) 10 x 1/2" screws on the left side of the
firebox bottom.
10. Attach two (2) flag terminals on wire harness to fan control
bracket.
11. Attach fan control bracket to top of inner casing with
10 x 1/2" screw. Refer to Figure 25 for correct position of
fan control bracket for 10,000 BTU/hr input or 20,000 BTU/
hr input.
Figure 24
Figure 23
OPTIONAL BLOWER INSTALLATION INSTRUCTIONS
Figure 21
Figure 22
Figure 25