Decide where the pump is to be mounted. For
optimal performance mount the pump such that
the fluid path flows uphill (with air and power
connections pointing down as shown in the
Images to the right).
Drill and tap 3 #6-32 holes using the baseplate
dimensional for positioning the holes.
Insert #6-32 socket head cap screws into location
for the key slot holes. Leave enough room for
base plate to slide under screw cap; about ¼”.
Slide pump into position using the key slot hole to
help hold pump in place.
Insert and tighten the remaining 2 #6-32 socket
head cap screws into position on opposite side of
pump.
Tighten the key slot screws.
The pump is now secured.
Attach liquid fittings inlet on the side with the air
and electrical connections, and the outlet on the
opposite side. Use a backer wrench so that the
fitting is not damaged.
Attach electrical connector to the M12 Turck male
receptacle.
Attach air pr
essure to the CDA inlet port using 1/8”
FNPT port.