background image

 
ALWAYS EMPTY THE WATER BOTTLE 
 

 

 
 
THE CONDENSER 

The condenser and ducting should be cleaned monthly or more frequently if the dryer is in constant use. 
See

 “CLEANING THE CONDENSER” 

below.

 

NOTE: 

The condenser will discolour through use.

 

REMOVING THE CONDENSER 

–Firmly pull the condenser out. 

RE-INSTALLING THE CONDENSER 

–Carefully push the condenser back into the machine, until it is pushed fully home and a “click” is heard.

 

IMPORTANT:

 

–Ensure all lint and fluff is removed from around the grille seal before closing or water may leak. 
-  The dryer may leak if the condenser is not correctly re-installed 

CLEANING THE CONDENSER 
CAUTION: 

For maximum efficiency, the plates are made from very thin aluminum and are easily 

damaged. Do not try to poke anything between the plates or use a hard object or tool for cleaning. At all 
times, handle the condenser carefully and avoid crushing the plates. 
–Remove the condenser (see above). 
–Flush the fluff from between the plates under running water and carefully shake off excess water

 

 

 
ANY PROBLEMS 

If the clothes are not dry after normal drying time: 
–Check that you used the correct heat setting. 
–Check that you have not set the timer within a cool down period. 
–Check that the lint filter has been cleaned. A blocked filter will restrict the airflow. 
–Check that the condenser unit and associated duct work are clean. If blocked, these will restrict the 
airflow. 
–Check that your dryer is heating - below the door to the left side, should feel warm to the touch after the 
first 10-15 minutes of its programme. 
Failure to heat may indicate the safety cut-out has operated. To reset, simply press the red button at the 
rear of the machine. If it has operated then a sharp “click” will be heard. 
This cut-out only operates if the airflow is severely restricted so make sure the filter is clean and that all 
other restrictions are removed before re-starting. 
If the cut-out continues to operate after checking the above points, you should contact your service agent. 
Check that the machine has the correct weight load in the drum before stating the appliance. 

- Open the door, pull out and empty the bottle. 
- Replace the bottle ensuring that it is pushed all the way in - if it is not, the 

dryer will not operate. 

- If the dryer is connected to a drain there is no need to empty the bottle but it 

must be correctly fitted to the machine. 

Whilst the condenser is removed, clean as much fluff as 
possible from inside the ducting by reaching a hand into the 
machine. In particular, keep the passage from the fan clear (on 
the right hand side of the condenser duct). 
After cleaning, re-install the condenser (see above). 

Summary of Contents for 93AW

Page 1: ...INSTRUCTIONS FOR USE TUMBLE DRYERS IMPORTANT PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE USING THIS APPLIANCE KEEP THEM IN A SAFE PLACE FOR FUTURE REFERENCE ...

Page 2: ...old waste pipe ensuring a gap between the end of the hose and any water in the waste pipe FINAL INSTALLATION The illustration shows the minimum space required by the dryer and the position of the waste pipe within this space and behind the dryer If a trap is fitted it must not obstruct the air inlet at the back of the dryer The waste pipe can be positioned on either side of the dryer If the waste ...

Page 3: ...lothes anti crease will automatically start once the drying cycle is complete Program 1 Extra dry clothes are dry enough to be put away Program 2 Cupboard dry clothes are dry enough to be put away Program 3 Mid dry depending upon fabric clothes are generally dry enough to be put away Program 4 Extra iron dry clothes are almost dry but can be easily ironed Program 5 Iron dry clothes are slightly da...

Page 4: ...Select the programme and the heat setting required Press the start button The drum will initially rotate in an anticlockwise direction The drum will now begin to rotate and will stop automatically when your clothes are dry The drum will stop and turn in the other direction for a short while every few minutes There is an automatic 12 minute cool down period at the end of every cycle during which th...

Page 5: ...t filter has been cleaned A blocked filter will restrict the airflow Check that the condenser unit and associated duct work are clean If blocked these will restrict the airflow Check that your dryer is heating below the door to the left side should feel warm to the touch after the first 10 15 minutes of its programme Failure to heat may indicate the safety cut out has operated To reset simply pres...

Page 6: ...okers as the performance of the dryer may be affected A carpet must not obstruct the ventilation openings in the base of the dryer Do not stack the tumble dryer on top of other appliances without the correct stacking kit Any electrical work required to install the appliance should be carried out by a qualified person It is important to clean the lint filter after each drying cycle and the condense...

Page 7: ...e tumble dryer Risk of fire DO NOT exceed the recommended maximum load DO NOT dry unwashed items in the tumble dryer DO NOT place articles in the dryer if anything other than a water solution has been used in the cleaning process DO NOT attempt to dry dripping wet articles DO NOT use the tumble dryer if you suspect that it is damaged in any way Under no circumstances should you attempt to repair t...

Page 8: ...4213 094 70703 Manufactured by Crosslee plc Lightcliffe Factory Halifax West Yorkshire HX3 8DE ...