ADDITIONAL SAFETY FEATURES
12
Automatic Shut Down & Related Safety Features.
This inverter has an unique LED indicator warning light system
which operates in conjunction with the
automatic shut down
feature.
These indicator lights operate as follows:
GREEN LED
: System ready.
RED LED
: System overload/automatic shut down.
1. Your inverter will shut down automatically when any of the
following problems occur:
2. The power input from the battery drops below 10 volts.
3. The power input from the battery exceeds 15 volts.
The inverters are also equipped with the following additional
safety features:
1. Thermal Cut Off:
Automatic shut down if internal
temperature exceeds safe design parameters.
2. Low Battery Voltage Alarm/Shutdown Protection:
a) When the input voltage from the 12 volt power source
drops below 10.5 volts, an audible tone will be heard. This
is the low battery voltage alarm.
b) The inverter will automatically shut down when the input
voltage drops below 10.0 volts. This protects the battery
from completely draining.
In the event of automatic shut down or continuous audible
alarm, turn the inverter rocker switch to the center OFF (O)
position until the source of the related problem has been
identified and resolved.