Making the Connection.
This inverter is designed to connect to your 12 volt battery using
the lighter socket plug or by the supplied battery cables (for
appliances over 150 watts, 400 watt model only).
1. Make certain that the inverter rocker switch is in the center
OFF (O) position.
2. Connect the cables to the power input terminals at the rear
of the inverter and tighten the screws to make a secure
connection. Do not use tools to tighten these screws.
Steps 3 - 5 are used when and appliance requires over
150 watts.* Step 6 is for appliances under 150 watts.*
3. Connect the cable from the (BLACK) Negative (-)
terminal on the inverter to the Negative (-) terminal on
the 12 volt power source. Make certain the connection
is secure.
4. Confirm that the cable you have just installed is properly
connected. Specifically, make certain that the cable is
connected to the Negative (-) terminals on both the
inverter and the 12 volt power source.
5. Connect the cable from the (RED) Positive (+) terminal
on the inverter to the Positive (+) terminal on the power
source.
6. Remove the lighter and push the adapter plug firmly
into the lighter socket.* (Make certain both the socket
and adapter plugs are clean.)
OPERATION