OPERATION

Making the Connection.

The PP750AC is designed to connect to your 12 volt battery
by the supplied #8 gauge cables.

1.

Make certain that the PP750AC rocker switch is in the
OFF (O) position.

2.  Connect the cables to the power input terminals at

the rear of the inverter and tighten the screws to make
a secure connection. 

Do not use tools to tighten

these screws.

3.  Connect the cable from the (BLACK) Negative (-) ter-

minal on the inverter to the Negative (-) terminal on
the 12 volt power source.  Make certain the connec-
tion is secure.

4.    Confirm that the cable you have just installed is prop-

erly connected.  Specifically, make certain that the
cable is connected to the Negative (-) terminals on
both the inverter and the 12 volt power source.

5.

Connect the cable from the (RED) Positive (+) terminal
on the inverter to the Positive (+) terminal on the
power source.

9

OPERATION

8

Note:

Loose connections can result in a severe decrease in
voltage which may cause damage to the wires and
insulation.

F a i l u re  to  make  proper  connection  between  the
inverter and the power source will result in reverse
polarity.  Reverse polarity will blow the internal fuses in
the inverter and may cause permanent damage to the
inverter.  Damage caused by reverse polarity is not
covered under the Whistler warranty.

Making the connection between the Positive (+) ter-
minals may cause a spark as a result of current flowing
to the capacitors in the inverter.  This is a normal
occurrence.  Due to the potential for sparking, how-
ever, it is extremely important that both the inverter
and the 12 volt battery be well removed from any pos-
sible source of flammable fumes or gases.

Failure to heed this warning could result in fire or
explosion.

If the supplied cables are too short to allow for place-
ment of the inverter in a desired location, the inverter
may be connected to the power source using a #4
wire, up to 12’ - #2 wire for longer lengths.  The steps
outlined for making the connection and the related
safety precautions remain unchanged.

6.

Turn the inverter rocker switch to the ON (I) position.
The LED Indicator Light should glow GREEN confirm-
ing that there is power running to the inverter.

PP750  Manual  3/6/02  2:25 PM  Page 11

Summary of Contents for GO AC PP750

Page 1: ... 479 273 6012 FX 479 273 2927 www whistlergroup com PRODUCT DEVELOPMENT CENTER 25 Industrial Ave Chelmsford MA 01824 TEL 978 244 1400 FX 978 244 1491 CUSTOMER RETURN CENTER 1201 N Dixieland Rd Rogers AR 72756 Consumer Relations Tel 800 531 0004 Email info whistlergroup com P N PP750MAN 2 WHISTLER 2002 PP750 Manual 3 6 02 2 25 PM Page 1 ...

Page 2: ...ression of our personality Whistler products are designed to make the time you spend in your vehicle more productive more fulfilling safer or just simply more fun Our mission is to provide products that improve your driving experience Whistler offers a complete line of DC to AC inverters ranging in capacity from 140 Watts to 2750 Watts These inverters offer advanced technology dependable operation...

Page 3: ...rom portable high power 12 volt sources 1 AC Output Sockets 2 On Off Switch 3 Power Overload LED 4 Power Cords 3 Topic Page Features Summary 3 Important Information 4 Inverter Basics 5 7 Getting Started Don t Push It Operation 8 12 Making the Connection Tips Recharging Equipment Changing the Fuse Power Source Additional Safety Features 13 14 Auto Shut Down Thermal Cut Off Low Battery Protection Ca...

Page 4: ...wattage rating As a general rule you can determine the required start up load by multiplying the wattage rating by 10 For further information on the fundamental operating prin ciples of Whistler inverters and related technical data see Technical Operating Principles 5 IMPORTANT INFORMATION Important Information About Your New Whistler Inverter This manual will provide you with directions for the s...

Page 5: ...continuous rating for up to 10 seconds To determine whether your inverter will operate a particular piece of equipment or appliance run a test The inverter is designed to shut down automatically in the event of a power overload Testing appliances and equipment with start up load ratings comparable to your inverter wattage rating will not damage it 7 INVERTER BASICS 6 If a piece of equipment or an ...

Page 6: ... make proper connection between the inverter and the power source will result in reverse polarity Reverse polarity will blow the internal fuses in the inverter and may cause permanent damage to the inverter Damage caused by reverse polarity is not covered under the Whistler warranty Making the connection between the Positive ter minals may cause a spark as a result of current flowing to the capaci...

Page 7: ...asily accessed at the back of the unit underneath the lift up covers OPERATION 7 Turn the inverter rocker switch to the OFF O position The GREEN LED Power Indicator light may blink briefly and or the internal audible alarm may make a momentary chirp This is normal 8 Confirm that the equipment or appliance to be oper ated is turned off Plug the equipment or appliance into one of the three AC recept...

Page 8: ...fe operation OPERATION 12 Note Make certain to correct the source of the overload which caused the blown fuse before turning your inverter back ON l The Power Source When the engine is off most batteries will provide ample power supply to the inverter for one to two hours The actual length of time is a function of several variables including the age and condition of the battery and the power deman...

Page 9: ... wheel gas brake and clutch pedals and gear shift 14 ADDITIONAL FEATURES CARE AND MAINTENANCE To maintain your inverter in proper working condition note the following important safety precautions MOISTURE Keep the inverter dry Do not expose it to moisture Do not operate the inverter if you the inverter the device being operated or any other sur faces that may come in contact with any power sources...

Page 10: ...l Types 1 Basic Operating Principles Whistler GO AC inverters work in two stages During the first stage the DC to DC converter increases the DC input voltage from the power source e g a 12 volt battery to 145 volts DC In the second stage the high voltage DC is converted to 110 volts 60 Hz AC using advanced power MOSFET transistors in a full bridge configuration The result is excellent overload cap...

Page 11: ...ers irons hair dryers toasters and heaters Before attempting to use a battery charger see page 11 Before attempting to use medical equipment see page 4 Use only fuses which conform with the design specifica tions outlined in this manual When operating the inverter with the engine off start the engine every hour and let it run for at least 10 minutes to recharge the battery In the event of automati...

Page 12: ...e a higher capacity draws too much power inverter or do not use this equipment Inverter is too hot thermal Allow inverter to cool shutdown mode Check for adequate ventilation Reduce the load on the inverter to rated continuous power output PROBLEM TV Interference Problem Solution Electrical interference from Add a Ferrite data line filter inverter on to the TV power cord This filter is available a...

Page 13: ... with a modified sine wave A larger inverter may be required WHISTLER 750 WATT INVERTER SPECIFICATIONS Maximum Continuous Power 750 Watts Maximum Surge Capability Peak Power 1500 Watts No Load Current Draw 0 35 A Waveform Modified Sine Wave Operating Input Voltage Range 9 5 16 Volts DC AC Receptacle Three 3 Prong Fuses Three 35 Amp Spade Type Approximate Dimensions 14 H x 7 25 W x 3 D Approximate ...

Page 14: ...s warranteed to the original purchas er for a period of two years from the date of original pur chase against all defects in materials and workmanship This limited warranty is void if the unit is abused modified installed improperly had its housing removed or has a missing serial number There are no express warranties cov ering this product other than those set forth in this warranty All express o...

Page 15: ...ect not to have your inverter repaired replaced it will be returned to you along with your certified check or money order IMPORTANT When returning your inverter for service be certain to include a daytime telephone number and email address if applicable Consumer Relations If you have questions concerning the operation of your Whistler inverter or require service during or after the warranty period...