Check Whistler’s online store for cable availability.
Making the Connection.
1. Make certain that the Power switch is in the center OFF (O)
position.
2. Connect the cables to the power input terminals at the rear
of the inverter and tighten the screws to make a secure
connection.
(To make these connections, install the wire connectors flush
with the metal backing plates and fasten the nuts securely.
3. Connect the cable from the Negative (-) terminal on the
inverter to the Negative (-) terminal on the 12 volt power
source. Make certain the connection is secure.
4. Confirm that the cable you have just installed is properly
connected. Specifically, make certain that the cable is
connected to the Negative (-) terminals on both the
inverter and the 12 volt power source.
5. Connect the cable from the Positive (+) terminal on the
inverter to the Positive (+) terminal on the power source.
NOTE:
• Loose connections can result in a severe decrease in
voltage which may cause damage to the wires and insulation.
• Failure to make proper polarity connection between the
inverter and the power source will result in reverse polarity.
Reverse polarity will blow the internal fuses in the inverter and
may cause permanent damage to the inverter.
Damage
caused by reverse polarity is not covered under the
12
OPERATION