22
WhisperPower
Lithium Plus 12 V 210 Ah 340 Ah
Load/Charger
Bi-stable Relay
Figure 11. Securing the terminal covers
4.6.2. Connecting a single Lithium battery to the load/charger
with a normal relay
Warning! Ensure you have completed all the previous steps described in chapter 4.5 before
connecting the battery to the load/charger.
1. Slide the terminal covers over the connection wires.
2. Connect the + terminal of the battery to the - or A1 terminal of the relay (Figure 12).
3. Connect the load or charger to the + or A2 terminal of the relay.
4. Connect the - terminal of the battery. Do not connect the - terminal first as this may lead to
short circuits (Figure 12).
5. Ensure both contacts are tightened to 20Nm.
6. Place the terminal covers over the terminals (Figure 13)