5
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
■
Drill
■
1¹⁄
4
" (3.0 cm) drill bit
■
¹⁄
8
" (3.0 mm) drill bit for pilot holes
■
Pencil
■
Wire stripper or utility knife
■
Tape measure or ruler
■
Caulking gun and weatherproof caulking compound
■
Flat-blade screwdriver
■
Phillips screwdriver
■
Saber or keyhole saw
■
Metal snips
Parts supplied
Remove parts from package. Check that all parts are included.
■
#8-18 x 1" (4.2 x 25 mm) flat-head screws (2)
■
(4.5 x 13 mm) truss-head screws (4)
■
Drywall anchors (2)
■
Mounting brackets (4)
■
(4.2 x 8.5 mm) mounting screws (2)
■
(4.2 x 8.5 mm) washers (2)
■
TORX
®†
T10 adapter (1)
■
3
1
/
4
" x 10" (8.3 cm x 25.4 cm) rectangular air transition (1)
■
Rectangular air damper
Parts needed
■
Wall or roof cap with damper to match vent system
■
3 - UL Listed wire connectors
■
Vent clamps/duct tape as required
For 7" (17.8 cm) round vented installations:
■
7" (17.8 cm) round metal vent system
For 3¹⁄
4
" x 10" (8.3 cm x 25.4 cm) rectangular vented
installations:
■
3¹⁄
4
" x 10" (8.3 cm x 25.4 cm) rectangular metal vent system
For non-vented (recirculation) installations:
■
Charcoal Filter Kit. For information on ordering, see the
“Accessories” section.
†
®
TORX is a registered trademark of Acument Intellectual Properties, LLC.
Location Requirements
IMPORTANT:
Observe all governing codes and ordinances.
■
It is the installer’s responsibility to comply with installation
clearances specified on the model/serial/rating plate. The
model/serial/rating plate is located inside the range hood on
the left wall.
■
Range hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
■
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance. Consult the
cooktop/range manufacturer installation instructions before
making any cutouts.
■
This range hood is recommended for use with cooktops with
a maximum total rating of 55,000 BTUs or less.
■
Grounded electrical outlet is required. See the “Electrical
Requirements” section.
■
All openings in ceiling and wall where range hood will be
installed must be sealed.
■
These range hoods are factory set for vented installations.
Models that are capable of being installed as non-vented
(recirculating) require charcoal filters. See the “Accessories”
section to order Charcoal Filter Kit.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home
Construction and Safety, title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A (latest edition) or with local
codes.
Product Dimensions
A. 8
25
/
64
" (21.3 cm)
B. Centerline
C. 1" (2.54 cm)
D. 8
31
/
32
" (22.8 cm)
E. 19
11
/
16
" (50 cm)
F. 1
1
/
2
" (3.8 cm)
G. 24" (61 cm)
H.
55
/
64
" (2.2 cm)
I. 6
19
/
54
" (16 cm)
J. 2" (5 cm)
A
C
D
E
F
G
H
I
J
B