4.1.3. Evaporator
Frost Free Type Evaporator, with suction line injected in the cabinet. Only the Evaporator can be substituted.
Due the internal configuration we strongly recommend do the interventions with the lokring connections.
1. Lokring connector
2. Defrost sensor
3. EPS - shim right
4. Thermofuse
5. Defrost shield
6. Deforst heater
7. EPS - shim left
8. Suction line
4.2. Defrost System
4.2.1. Defrost Heater
The Defrost Heater involves all the evaporator extension, presenting a better performance of the system. Its
operation (on/off) is also commanded by the electronic control and its electrical features are: Power 275(W),
value 194 to 227 ohms.
The lower part of the defrost heater is fixed at the defrost gutter through claws in order to avoid ice building on
this place. Always ensure the contact between these parts.
4.2.2. Defrost sensor
It’s located at the freezer compartment, along with the evaporator returning pipe. The defrost sensor is
responsible for sending signs to the electronic control, which will command the ending of the adaptive defrost,
turning off the defrost heater, containing a similar function to the well-known defrost bimetal.