For Service Technician Use Only
COMPONENT TESTING
3-18
n
Whirlpool
®
Smart Wall Ovens
Component
Serviceable
Side
Procedure
Results-Resistance
Component
Location
Inverter
Top
Check wiring to MW inverter:
1.
Unplug microwave oven or disconnect power.
2.
Visually inspect 4 connectors on the MW
inverter boards, CN701, CN702, CN703,
and E701 to see whether there are signs of
overheating or any signs of failure due to
loose wires, bad crimping, etc.
3.
Reassemble all parts and panels before
operating.
4.
Plug in microwave oven or reconnect power.
H
Magnetron
Top
1.
Unplug microwave oven or disconnect power.
2.
Remove wire leads. Check that the seal is in
good condition.
3.
Measure resistance.
4.
Replace wire leads.
5.
Reassemble all parts and panels before
operating.
6.
Plug in microwave oven or reconnect power.
Filament Terminals
Normal = <1 W
Filament to Chassis
Normal = Infinite
K
Line Filter
Top
1.
Unplug microwave oven or disconnect power.
2.
Remove wire leads.
3.
Measure resistance.
4.
Replace wire leads.
5.
Reassemble all parts and panels before
operating.
6.
Plug in microwave oven or reconnect power.
P31 to P32, P33 to P34
Normal >/= 300 kΩ
Abnormal </= 100 kΩ
P31 to P34, P32 to P33
Normal = 0 Ω
Abnormal >/= 100 kΩ
F
Humidity Sensor
Top
1.
Unplug microwave oven or disconnect power.
2.
Remove the 3-pin connector from MW ACU.
3.
Measure resistance across pins 1 and 3 and
across pins 2 and 3.
4.
Replace the 3-pin connector from MW ACU.
5.
Reassemble all parts and panels before
operating.
6.
Plug in microwave oven or reconnect power.
Normal = 2.8 kΩ
(approximately) at 77°F ±
10°F (25°C ± 10°C)
Abnormal = Infinite
D
Magnetron
Thermistor
1.
Unplug microwave oven or disconnect power.
2.
Remove wire leads.
3.
Measure resistance.
4.
Replace wire leads.
5.
Reassemble all parts and panels before
operating.
6.
Plug in microwave oven or reconnect power.
Normal = 10 kΩ
(approximately) at
77°F ± 10°F
(25°C ± 10°C)
Abnormal = Infinite
J
Cavity Temp Sensor
Rear
1.
Unplug microwave oven or disconnect power.
2.
Remove wire leads.
3.
Measure resistance.
4.
Replace wire leads.
5.
Reassemble all parts and panels before
operating.
6.
Plug in microwave oven or reconnect power.
Normal = 230 kΩ
(approximately)
at 77°F ± 10°F
(25°C ± 10°C)
Abnormal = Infinite
G
Summary of Contents for WOC75EC7H
Page 4: ...iv n Whirlpool Smart Wall Ovens ...
Page 18: ...GENERAL INFORMATION 1 14 n Whirlpool Smart Wall Ovens ...
Page 47: ...For Service Technician Use Only DIAGNOSTICS TROUBLESHOOTING Whirlpool Smart Wall Ovens n 2 29 ...
Page 48: ...For Service Technician Use Only DIAGNOSTICS TROUBLESHOOTING 2 30 n Whirlpool Smart Wall Ovens ...
Page 67: ...For Service Technician Use Only COMPONENT TESTING Whirlpool Smart Wall Ovens n 3 19 ...
Page 68: ...For Service Technician Use Only COMPONENT TESTING 3 20 n Whirlpool Smart Wall Ovens ...
Page 82: ...COMPONENT ACCESS 4 14 n Whirlpool Smart Wall Ovens ...
Page 84: ......