7

Custom under counter installation (dryer only):

Closet Installation (stacked washer and dryer):

NOTE: 

Some models not recommended for undercounter 

installation.

Mobile home – Additional installation requirements: 

This dryer is suitable for mobile home installations.  

The installation must conform to the Manufactured  

Home Construction and Safety Standard, Title 24 CFR,  

Part 3280 (formerly the Federal Standard for Mobile home 

construction and Safety, Title 24, HUD Part 280) or Standard 

CAN/CSA-Z240 MH.

Mobile home installations require: 

All dryers:

 

Metal exhaust system hardware, available for purchase  

from your dealer. For further information, see “Assistance  

or Service” section in your Use and Care Guide.

 

Special provisions must be made in mobile homes to  

introduce outside air into dryer. Openings (such as a  

nearby window) should be at least twice as large as  

dryer exhaust opening.

For gas dryers mobile home installations:

 

Mobile Home Installation Hold-down Kit Part Number 

346764 is available to order. For further information, see  

“Assistance or Service” section in your Use and Care Guide.

1"

(25 mm)

1"

(25 mm)

5

1

/

2

"

(140 mm)

24 in.

2

(155 cm

2

)

48 in.

2

(310 cm

2

)

3"

(76 mm)

3"

(76 mm)

6"

(152 mm)

71"

(1803 mm)

1"

(25 mm)

1"

(25 mm)

39" min.

(990 mm)

ELECTRIC DRYER  

POWER HOOKUP – CANADA ONLY

ELECTRICAL REQUIREMENTS

It is your responsibility: 

 

To contact a qualified electrical installer.

 

To be sure that the electrical connection is adequate and in 

conformance with Canadian Electrical Code, C22.1 – latest 

edition and all local codes. A copy of above codes standard 

may be obtained from: Canadian Standards Association,  

178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.

 

To supply the required 4-wire, single phase, 120/240 volt,  

60 Hz, AC only electrical supply on a separate 30-amp 

circuit, fused on both sides of the line. A time-delay fuse or 

circuit breaker is recommended. Connect to an individual 

branch circuit. 

 

This dryer is equipped with a CSA 

International Certified Power Cord 

intended to be plugged into a standard  

14-30R wall receptacle. The cord is 5 ft. 

(1.52 m) long. Be sure wall receptacle is 

within reach of dryer’s final location.

If using a replacement power supply cord, it is recommended that 

you use Power Supply Cord Replacement Part Number 9831317.

For further information, please reference service numbers located 

in “Assistance or Service” section of your Use and Care Guide.

4-wire receptacle 

(14-30R)

GROUNDING INSTRUCTIONS

SAVE THESE INSTRUCTIONS

■  

For a grounded, cord-connected dryer: 

This dryer must be grounded. In the event of malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an equipment- 
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes 
and ordinances.

WARNING:

 

Improper connection of the equipment- 

grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or service representative 
or personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug provided with 
the dryer: if it will not fit the outlet, have a proper outlet 
installed by a qualified electrician.

Summary of Contents for WGD9051YW

Page 1: ..._____________________ NOTES CONCERNANT L INSTALLATION Table des matières SÉCURITÉ DE LA SÉCHEUSE 17 EXIGENCES D INSTALLATION 19 Outillage et pièces 19 Exigences d emplacement 20 Raccordement à l alimentation électrique de la sécheuse électrique Canada seulement 22 Raccordement d une sécheuse à gaz 23 L ÉVACUATION 25 Exigences concernant l évacuation 25 Planification du système d évacuation 26 Inst...

Page 2: ...2 DRYER SAFETY ...

Page 3: ...3 IMPORTANT When discarding or storing your old clothes dryer remove the door ...

Page 4: ... purchasing parts Check code requirements Some codes limit or do not permit installing dryer in garages closets mobile homes or sleeping quarters Contact your local building inspector Parts supplied all models Flat blade screwdriver 2 Phillips screwdriver Adjustable wrench that opens to 1 25 mm or hex head socket wrench Wire stripper direct wire installations Tin snips new vent installations Caulk...

Page 5: ...r If slope is greater than 1 25 mm install Extended Dryer Feet Kit Part Number 279810 If not level clothes may not tumble properly and automatic sensor cycles may not operate correctly For garage installation place dryer at least 18 460 mm above floor If using a pedestal you will need 18 460 mm to bottom of dryer For each arrangement consider allowing more space for ease of installation and servic...

Page 6: ... on sides and rear Additional spacing should be considered for ease of installation and servicing Additional clearances might be required for wall door and floor moldings Additional spacing should be considered on all sides of the dryer to reduce noise transfer For closet installation with a door minimum ventilation openings in the top and bottom of the door are required Louvered doors with equiva...

Page 7: ...y be obtained from Canadian Standards Association 178 Rexdale Blvd Toronto ON M9W 1R3 CANADA To supply the required 4 wire single phase 120 240 volt 60 Hz AC only electrical supply on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Connect to an individual branch circuit This dryer is equipped with a CSA International Certified Power Co...

Page 8: ...th a different gas without consulting your gas company WARNING Explosion Hazard Use a new CSA International approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 13 330 mm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel a...

Page 9: ...NPT minimum plugged tapping D 1 2 NPT gas supply line E Gas shutoff valve GAS SUPPLY LINE Must include 1 8 NPT minimum plugged tapping accessible for test gauge connection immediately upstream of the gas connection to the dryer A B E D C GAS SUPPLY CONNECTION REQUIREMENTS Use an elbow and a 3 8 flare x 3 8 NPT adapter fitting between the flexible gas connector and the dryer gas pipe as needed to a...

Page 10: ...e total length should not exceed 73 4 ft 2 4 m NOTE If using an existing vent system clean lint from entire length of the system and make sure exhaust hood is not plugged with lint Replace plastic or metal foil vents with rigid metal or flexible metal vents Review Vent System Charts and if necessary modify existing vent system to achieve best drying performance 4 102 mm 4 102 mm heavy metal exhaus...

Page 11: ...available with one offset elbow Periscope installation Optional exhaust installations If you prefer dryer may be converted to exhaust out right side left side all models except WGD9051Y or through bottom You must contact your local dealer to have dryer converted Use 4 Way Exhaust Kit Part Number W10470674 NOTE On Model WGD9051Y only do not exhaust out the left side Special provisions for mobile ho...

Page 12: ...urns When using elbows or making turns allow as much room as possible Bend vent gradually to avoid kinking Use as few 90 turns as possible Determine vent length and elbows needed for best drying performance Use the following Vent System Charts to determine type of vent material and hood combinations acceptable to use NOTE Do not use vent runs longer than those specified in Vent System Charts Exhau...

Page 13: ...gs must be used to connect dryer to existing gas line A recommended connection is shown Your connection may be different according to supply line type size and location A 3 8 flexible gas connector B 3 8 dryer pipe C 3 8 to 3 8 pipe elbow D 3 8 pipe to flare adapter fitting Open shut off valve 3 Open shut off valve in supply line valve is open when handle is parallel to gas pipe Then test all conn...

Page 14: ...er fill valve and tighten coupling 5 Attach other end of long hose to fill valve at bottom of dryer back panel Screw on coupling by hand until it is seated on fill valve connector Using pliers tighten the couplings an additional two thirds turn NOTE Do not overtighten Damage to the coupling can result Attach short hose and Y connector 2 If space permits attach the brass female end of the Y connect...

Page 15: ...isture sensing system to operate correctly CONNECT VENT 1 Connect vent to exhaust outlet Using a 4 102 mm clamp connect vent to exhaust outlet in dryer If connecting to existing vent make sure vent is clean Dryer vent must fit over dryer exhaust outlet and inside exhaust hood Check that vent is secured to exhaust hood with a 4 102 mm clamp Move dryer to final location 2 Move dryer to final locatio...

Page 16: ...t or repair Electric Models q Plug into a grounded outlet Gas Models q Check that gas supply is on q Check for leaks All Models q Select a Timed Dry heated cycle and start dryer Do not select Air Only Temperature setting If dryer will not start check the following Controls are set in a running or On position Start button has been pushed firmly Dryer is plugged into an outlet and or electrical supp...

Page 17: ...17 SÉCURITÉ DE LA SÉCHEUSE ...

Page 18: ... CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas toucher à un commutateur électrique ne pas utiliser le téléphone se trouvant sur les lieux Évacuer tous les gens de la pièce de l édifice ou du quartier Appeler immédiatement le fournisseur de gaz d un téléphone voisin Suivre ses instructions À défaut de joindre votre fournisseur de gaz appeler les pompiers L installation et l entr...

Page 19: ...au gaz Composé d étanchéité des raccords filetés résistant au gaz propane Couteau utilitaire Pièces fournies tous les modèles Pieds de nivellement 4 Connecteur en Y Tuyau d alimentation court Tuyau d alimentation long Rondelle de caoutchouc Pièces fournies modèles à vapeur OUTILLAGE ET PIÈCES Rassembler les outils et composants nécessaires avant d entreprendre l installation Outils nécessaires pou...

Page 20: ... tuyau court si nécessaire fournis 20 à 100 lb po 138 à 690 kPa pour un rendement optimal Un plancher de niveau ayant une pente maximale de 1 25 mm sous l ensemble de la sécheuse Si la pente est supérieure à 1 25 mm installer un ensemble de pieds d extension pour sécheuse pièce n 279810 Si la sécheuse n est pas d aplomb le linge peut ne pas culbuter convenablement et les programmes automatiques co...

Page 21: ...installation et l entretien Un espace supplémentaire peut être requis pour les moulures de porte et de plancher et pour les plinthes Un espace supplémentaire doit être envisagé de tous les côtés de la sécheuse afin de réduire le transfert de bruit Pour installation dans un placard avec porte on doit prévoir des ouvertures minimums d entrée d air en haut et en bas de la porte Les portes à claire vo...

Page 22: ...e d ancrage au sol pour installation en résidence mobile pièce numéro 346764 Pour plus d informations voir la section Assistance ou service dans le Guide d utilisation et d entretien RACCORDEMENT À L ALIMENTATION ÉLECTRIQUE DE LA SÉCHEUSE ÉLECTRIQUE CANADA SEULEMENT SPÉCIFICATIONS ÉLECTRIQUES C est à l utilisateur qu incombe la responsabilité de Contacter un électricien qualifié S assurer que le r...

Page 23: ...reliée à la terre et connectée par un cordon Cette sécheuse doit être reliée à la terre En cas de mauvais fonctionnement ou de panne la liaison à la terre réduira le risque de choc électrique en offrant au courant électrique un acheminement d évacuation de moindre résistance Cette sécheuse est alimentée par un cordon électrique comportant un conducteur relié à la terre et une fiche de branchement ...

Page 24: ...obturé filetage NPT de 1 8 ou plus accessible pour le raccordement de l instrument de mesure immédiatement en amont de la connexion d alimentation en gaz de la sécheuse A Connecteur de gaz flexible de 3 8 B Adaptateur de tuyau au joint conique de 3 8 C Connecteur obturé filetage NPT de 1 8 ou plus D Canalisation de gaz NPT de 1 2 E Robinet d arrêt du gaz Un tuyau IPS de 1 2 est recommandé Pour les...

Page 25: ...ur éviter tout affaissement et déformation susceptible de réduire la capacité d évacuation et le rendement Ne pas installer le conduit dans les cavités fermées des murs plafonds ou planchers La longueur totale ne doit pas excéder 73 4 pi 2 4 m 4 102 mm Conduit d évacuation en métal lourd de 4 102 mm REMARQUE Lors de l utilisation d un système de décharge existant nettoyer et éliminer la charpie su...

Page 26: ...c des vis ou avec tout autre dispositif de serrage qui se prolonge à l intérieur du conduit et où la charpie risque de s accrocher Ne pas utiliser de ruban adhésif pour conduit PLANIFICATION DU SYSTÈME D ÉVACUATION Installations d évacuations recommandée Les installations typiques consistent à acheminer le conduit d évacuation à l arrière de la sécheuse D autres installations sont possibles Autres...

Page 27: ...le de séchage Utiliser les Tableaux des systèmes d évacuation suivant pour déterminer le type de matériel d évacuation et les combinaisons de hotte acceptables REMARQUE Ne pas utiliser de conduits de longueur supérieure à la valeur spécifiée dans les Tableaux des systèmes d évacuation Si la longueur du circuit est supérieure à la valeur spécifiée dans le tableau on observera Un cycle de vie réduit...

Page 28: ...non par le panneau de commande et incliner soigneusement la sécheuse sur le carton INSTALLATION DU CIRCUIT D ÉVACUATION 12 min 305 mm 12 min 305 mm Installer le clapet d évacuation 1 Raccorder le conduit d évacuation au clapet 2 Installer un clapet d évacuation et calfeutrer l ouverture murale à l extérieur autour du clapet d évacuation Le conduit doit se trouver par dessus le clapet d évacuation ...

Page 29: ...e robinet d arrêt de la canalisation d alimentation le robinet est ouvert lorsque la manette est parallèle à la canalisation de gaz Vérifier ensuite tous les raccordements en les badigeonnant d une solution de détection des fuites non corrosive approuvée L apparition de bulles indique la présence d une fuite Réparer toute fuite éventuelle TEFLON est une marque déposée de E I Du Pont De Nemours et ...

Page 30: ...Y Visser le raccord à la main pour qu il repose sur le connecteur Terminer le serrage des raccords de deux tiers de tour supplémentaire avec une pince REMARQUE Ne pas serrer excessivement Le raccord risque d être endommagé Serrer les raccords 3 Terminer le serrage des raccords de deux tiers de tour supplémentaire avec une pince REMARQUE Ne pas serrer excessivement Le raccord risque d être endommag...

Page 31: ...cuation à la bouche d évacuation 1 Déplacer la sécheuse à son emplacement final 2 À l aide d une bride de serrage de 4 102 mm relier le conduit d évacuation à la bouche d évacuation de la sécheuse Si on utilise le conduit d évacuation existant s assurer qu il est propre Le conduit d évacuation de la sécheuse doit être fixé par dessus la bouche d évacuation de la sécheuse et à l intérieur du clapet...

Page 32: ...possible de commander un nécessaire de superposition numéro 8572546 Pour plus de renseignements voir a section Assistance ou Service dans le Guide d utilisation et d entretien ACHEVER L INSTALLATION LISTE DE VÉRIFICATION q Vérifier que toutes les pièces sont maintenant installées S il reste une pièce passer en revue les différentes étapes pour découvrir laquelle aurait été oubliée q Vérifier la pr...

Reviews: