background image

9

Reversible Super Wide Side-Swing Door

1. Place towel (A) on top of dryer to protect surface.
2. Open dryer door. Remove bottom screws from cabinet side of 

hinges (D). Loosen (do not remove) top screws from cabinet 
side of hinges.

3. Lift door until top screws in cabinet are in large part of hinge 

slot. Pull door forward off screws. Set door (handle side up) on 
top of dryer. Remove top screws from cabinet.

4. Remove screws attaching hinges to door.
5. Remove screws at top, bottom and side of door (4 screws). 

Holding door over towel on dryer, grasp sides of outer door 
and carefully lift to separate it from inner door. Do not pry 
apart with putty knife. Do not pull on door seal or plastic door 
catches.

6. Be careful to keep cardboard spacer centered between doors. 

Reattach outer door panel to inner door panel so handle is on 
the side where hinges were just removed.

7. Attach door hinges to door so large part of hinge slot is at 

bottom of hinge.

8. Remove door strike (E) from cabinet. Use a small, flat-blade 

screwdriver to carefully remove 4 hinge hole plugs (F) on left 
side of cabinet. Insert plugs in hinge holes on right side of 
cabinet.

9. Insert screws in bottom holes on left side of cabinet. Tighten 

screws halfway. Position door so large end of door hinge slot 
is over screws. Slide door up so screws are in bottom of slots. 
Tighten screws. Insert and tighten top screws in hinges.

10. Remove door strike plug (B). Insert the door strike you 

removed in Step 8 in hole and secure with screw. Insert door 
strike plug in original door strike hole and secure with screw. 

11. Close door and check that door strike aligns with door catch 

(C). If needed, slide door catch left or right within slot to adjust 
alignment.

Complete Installation

1. Check to be sure all parts are now installed. If there is an extra 

part, go back through the steps to see which step was 
skipped.

2. Check to be sure you have all of your tools.
3. Dispose of all packaging materials. 
4. Check the dryer’s final location. Be sure the vent is not 

crushed or kinked.

5. Check to be sure the dryer is level. See “Level Dryer.”

6. Plug into a grounded 3 prong outlet. Turn power on.
7. Remove the blue protective film on the console and any tape 

remaining on the dryer.

8. Read your “Dryer User Instructions.”
9. Wipe the dryer drum interior thoroughly with a damp cloth to 

remove any dust.

10. Set the dryer on a full heat cycle (not an air cycle) for 

20 minutes and start the dryer.
If the dryer will not start, check the following:

Dryer is plugged into a grounded 3 prong outlet.

Electrical supply is connected.

House fuse is intact and tight, or circuit breaker has not 
tripped.

Dryer door is closed.

11. When the dryer has been running for 5 minutes, open the 

dryer door and feel for heat. If you do not feel heat, turn the 
dryer off and check to see whether gas supply line shutoff 
valve is open. 

If the gas supply line shutoff valve is closed, open it, then 
repeat the 5-minute test as outlined above.

If the gas supply line shutoff valve is open, contact a 
qualified technician.

A

C

B

D

F

E

Summary of Contents for WGD5200T

Page 1: ...ecadora 17 Conexión del suministro de gas 17 Conexión del ducto de escape 18 Cómo invertir el cierre de la puerta opcional 18 Complete la instalación 19 8562582 You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to reduce the chance of injury and tell ...

Page 2: ...ors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performe...

Page 3: ...tion of the dryer in garages closets mobile homes or sleeping quarters Contact your local building inspector NOTE No other fuel burning appliance can be installed in the same closet as a dryer Installation Clearances The location must be large enough to allow the dryer door to open fully Dryer Dimensions Most installations require a minimum 5 14 cm clearance behind the dryer for the exhaust vent w...

Page 4: ...oor well of your dryer If this information does not agree with the type of gas available contact your dealer or call the phone numbers referenced on the front page of your Dryer User Instructions A Recessed area B Side view closet or confined area C Closet door with vents A B C 18 45 7 cm 1 2 5 cm 29 73 66 cm 1 2 5 cm 1 2 5 cm 14 max 35 6cm 27 70 5 cm 5 14 cm 48 in 310 cm 2 2 24 in 155 cm 2 2 3 7 ...

Page 5: ...er has been converted to use L P gas L P compatible copper tubing can be used If the total length of the supply line is more than 20 ft 6 1 m use larger pipe NOTE Pipe joint compounds that resist the action of L P gas must be used Do not use TEFLON tape Dryer Gas Pipe The gas pipe that comes out through the rear of your dryer has a male pipe thread A NPT dryer pipe Burner Input Requirements Elevat...

Page 6: ... metal or flexible metal vent Alternate installations for close clearances Venting systems come in many varieties Select the type best for your installation Two close clearance installations are shown Refer to the manufacturer s instructions NOTE The following kits for close clearance alternate installations are available for purchase Please reference the Assistance or Service section of your Drye...

Page 7: ...raightest path possible See Determine Vent Length Avoid 90º turns Use clamps to seal all joints Do not use duct tape screws or other fastening devices that extend into the interior of the vent to secure vent InstallLevelingLegs 1 To protect the floor use a large flat piece of cardboard from the dryer carton Place cardboard under the entire back edge of the dryer See illustration 2 Firmly grasp the...

Page 8: ...ectVent 1 Using a 4 10 2 cm clamp connect vent to exhaust outlet in dryer If connecting to existing vent make sure the vent is clean The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood Make sure the vent is secured to exhaust hood with a 4 10 2 cm clamp 2 Move dryer into final position Do not crush or kink vent Make sure dryer is level 3 On gas models Check to be sure...

Page 9: ...rt the door strike you removed in Step 8 in hole and secure with screw Insert door strike plug in original door strike hole and secure with screw 11 Close door and check that door strike aligns with door catch C If needed slide door catch left or right within slot to adjust alignment CompleteInstallation 1 Check to be sure all parts are now installed If there is an extra part go back through the s...

Page 10: ...l símbolo de advertencia de seguridad y de la palabra PELIGRO o ADVERTENCIA Estas palabras significan INSTRUCCIONES IMPORTANTES DE SEGURIDAD Antes de guardar o descartar su vieja secadora quítele la puerta GUARDE ESTAS INSTRUCCIONES ADVERTENCIA Para su seguridad la información en este manual debe ser observada para minimizar el riesgo de incendio o explosión o para prevenir daños a propiedades her...

Page 11: ... secadora y carga de 200 lbs 90 7 kg También se debe considerar espacio adicional para otro electrodoméstico que le acompañe Un piso nivelado con un declive máximo de 1 2 5 cm debajo de la secadora completa Si el declive es mayor que 1 2 5 cm instale el Juego de extensión de patas de la secadora Pieza No 279810 La ropa quizás no rote adecuadamente y los modelos con ciclos del sensor automático pos...

Page 12: ...ren aberturas de ventilación mínimas en la parte superior e inferior de la puerta Se aceptan puertas tipo persianas con aberturas de ventilación equivalentes También se debe considerar espacio adicional para otro electrodoméstico que le acompañe Requisitos de instalación adicionales para las casas rodantes Esta secadora es apropiada para instalaciones en casas rodantes La instalación debe ajustars...

Page 13: ...a tierra de 3 terminales No quite el terminal de conexión a tierra No use un adaptador No use un cable eléctrico de extensión No seguir estas instrucciones puede ocasionar la muerte incendio o choque eléctrico INSTRUCCIONES PARA LA CONEXIÓN ATIERRA GUARDE ESTAS INSTRUCCIONES Para la conexión de una secadora mediante cable eléctrico conectado a tierra Esta secadora debe estar conectada a tierra En ...

Page 14: ...al no use tubería de cobre Un adaptador abocinado NPT de por entre el tubo de la secadora y la tubería aprobada de Las longitudes superiores a los 20 pies 6 1 m deberán usar tuberías más largas y un accesorio adaptador de tamaño distinto Si su secadora ha sido convertida para usar gas L P se puede usar tubería de cobre compatible de L P de Si la longitud total de la línea de suministro es mayor qu...

Page 15: ...vitar que se doble y se tuerza lo cual podría dar lugar a una reducción del flujo de aire y un funcionamiento insuficiente Una capota de ventilación debe tapar el ducto de escape para evitar el ingreso de roedores e insectos a la casa La capota de ventilación debe estar por lo menos a 12 30 5 cm de distancia del piso o de cualquier objeto que pudiese estar en el trayecto del ducto de escape como f...

Page 16: ... o metal flexible El número de codos utilizados Tipo de capota Los estilos recomendados de capotas de ventilación se ilustran aquí El estilo de capota de ventilación angular que se ilustra a continuación es aceptable Vea en el cuadro de longitudes de ducto de escape uno que vaya de acuerdo con su tipo de capota de ventilación para fijarse en las longitudes máximas del ducto de escape que usted pue...

Page 17: ...el ducto de escape 6 Una vez que la conección esté hecha y que la secadora esté en su ubicación final quite los postes esquinales y el cartón Para uso en casas rodantes Las secadoras a gas deben ser aseguradas al piso con firmeza La instalación en casas rodantes requiere el Juego de Instalación para casas rodantes Vea Instrucciones para el usuario de la secadora para información sobre cómo ordenar...

Page 18: ...te para separarla de los tornillos Coloque la puerta encima de la secadora Extraiga los tornillos superiores del gabinete 4 Use un destornillador pequeño de hoja plana para quitar con cuidado los cuatro tapones D de los orificios de la bisagra que están en el lado izquierdo del gabinete Introduzca los tapones en los agujeros de la bisagra en el lado derecho del gabinete 5 Introduzca los tornillos ...

Page 19: ...con un tornillo 11 Cierre la puerta y asegúrese de que el interruptor de la misma esté alineado con el pestillo de la puerta C Si es necesario deslice el pestillo de la puerta hacia la izquierda o derecha dentro de la ranura a fin de ajustar la alineación Completelainstalación 1 Revise para cerciorarse de que todas las piezas estén instaladas Si hay alguna pieza extra vuelva a revisar todos los pa...

Page 20: ...l rights reserved Todos los derechos reservados Benton Harbor Michigan 49022 TM DURASAFE is a trademark of Whirlpool U S A TM DURASAFE es una marca de comercio de Whirlpool EE UU 4 04 Printed in U S A Impreso en EE UU ...