background image

Because Whirlpool Corporation policy includes a continuous commitment to improve 

Dimensions are for planning purposes only. For complete details, see Installation 

our products, we reserve the right to change materials and specifications without notice. 

Instructions packed with product. Specifications subject to change without notice.

ELECTRICAL REQUIREMENTS

A 120 volt, 60 Hz., AC only, 15- or 20-amp, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is 

recommended that a separate circuit serving only this appliance be provided.

Minimum diameter for a standpipe drain: 2" (51 mm). Minimum 

carry-away capacity: 17 gal. (64 L) per minute. A 1/4" (6 mm)  

diameter to 1" (25 mm) diameter Standpipe Adapter Kit is  

available (Part Number 3363920). Top of standpipe must be  

at least 30" (762 mm) high; install no higher than 96" (2.4 m)  

from bottom of washer. If you have an overhead sewer and  

need to pump higher than 96 inches, a sump pump and  

associated hardware are needed. See “Alternative Parts”.

30"

(762 mm)

4

1

/

2

"

(113 mm)

DRAIN SYSTEM

Drain system can be installed using a floor drain, wall standpipe,  

floor standpipe, or laundry tub. Select method you need. 

IMPORTANT:

 To avoid siphoning, only 4

1

/

2

" (113 mm) of drain 

hose should be inside standpipe. Always secure drain hose with 

beaded tie strap.

Floor standpipe drain system

Floor drain system requires a Siphon Break Kit (Part Number 

285834), 2 Connector Kits (Part Number 285835), and an  

Extension Drain Hose (Part Number 285863) that may be  

purchased separately. See “Alternative Parts”. Minimum siphon 

break height: 28" (710 mm) from bottom of washer. (Additional 

hoses may be needed.)

30"

(762 mm)

28"

(710 mm)

Minimum capacity: 20 gal. (76 L). Top of laundry tub must  

be at least 30" (762 mm) above floor; install no higher than  

96" (2.4 m) from bottom of washer. 

Floor drain system

4

1

/

2

"

(113 mm)

30"

(762 mm)

30"

(762 mm)

Laundry tub drain system

Wall standpipe drain system

4

1

/

2

"

(113 mm)

See requirements for floor standpipe drain system.