11
Level Range
1.
Place level on the oven bottom, as indicated in one of the
two figures below, depending on the size of the level. Check
with the level side to side and front to back.
2.
If range is not level, use a wrench or pliers to adjust leveling
legs up or down until the range is level.
NOTE:
Range must be level for satisfactory baking
performance and best cleaning results using AquaLift
®
Self-Clean Technology.
Make Gas Connection
This range is factory-set for use with Natural gas. To use this
range with propane gas, see the “Gas Conversions” section
before connecting this range to the gas supply. Gas conversions
from Natural gas to Propane gas or from Propane gas to Natural
gas must be done by a qualified installer.
Typical Flexible Connection
1.
Apply pipe-joint compound made for use with propane gas
to the smaller thread ends of the flexible connector adapters.
See B and G in the following illustration.
2.
Attach one adapter to the gas pressure regulator and
the other adapter to the gas shut-off valve. Tighten both
adapters, being certain not to move or turn the gas pressure
regulator.
3.
Use a 15/16" (24 mm) combination wrench and an adjustable
wrench to attach the flexible connector to the adapters.
IMPORTANT:
All connections must be wrench-tightened.
Do not make connections to the gas regulator too tight.
Making the connections too tight may crack the regulator
and cause a gas leak. Do not allow the regulator to turn
when tightening fittings.
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have 1/2"
[13 mm] male pipe thread)
D. Flexible connector
E. Manual gas shut-off valve
F. 1/2" (13 mm) or 3/4" (19 mm)
gas pipe
G. Use pipe-joint compound.
H. Adapter
Complete Connection
1.
Check that the gas pressure regulator shut-off valve is in the
on position.
A. Gas pressure regulator shut-off valve
shown in the “on” position
2.
Open the manual shut-off valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
3.
Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
A
B C
D
E
F
G
H
A
A
B
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make
sure gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Summary of Contents for WEG750H0HB
Page 70: ...70 Notas ...
Page 71: ...71 Notas ...