background image

04/06

FOR SERVICE TECHNICIAN’S USE ONLY

PART NO. W10054150

TECH SHEET - DO NOT DISCARD

PAGE 12

7.

Locking tabs located at the bottom of
the console insert panel secure the
user interface assembly to the console
insert panel. Using a flat-blade
screwdriver, gently apply pressure to
the locking tabs to release the user
interface assembly. See figure 16.

Reinstalling the Electronic
Assemblies

Refer to preceding removal sections and
replace in reverse order.

NOTE:

When replacing the cycle selector

switch, make sure that the shaft is positioned
through the center of the shaft seal that is
captive between the decorative overlay and
the console panel insert.

NOTE:

When reconnecting wire

connections, be sure to route the user
interface wires beneath the retainer clips on
the user interface back cover.

REMOVING THE BACK PANEL

1.

Unplug dryer or disconnect power.

2.

Remove the cover plate screw and cover
plate. See figure 17.

3.

Remove the nine rear screws from the
back panel, then remove panel.

Cover Plate Screw

Cover Plate

Figure 17.

Remove screws.

Locking

Tabs

User Interface

Assembly

Cycle Selector

Switch

Figure 16.

Gently apply pressure to

locking tabs to release the user interface
assembly.

SOFTWARE COPYRIGHTED.

MANUFACTURED UNDER ONE OR MORE

OF THE FOLLOWING U.S. PATENTS:

4,669,200
4,700,495
4,754,556
4,840,285
4,865,366
4,899,464
4,908,959

4,989,347
5,066,050
5,560,120
5,809,828
6,020,698
6,047,486
6,199,300

6,446,357
6,597,144
6,604,298
6,685,241
6,732,447
6,784,673
6,819,255

D314,261
D314,262
D457,991
D457,992
D495,453

Summary of Contents for WED6200SW1

Page 1: ...ith all indicators off or with only the Clothes Dry indicator on 2 Select any one button except Pause Cancel and follow the steps below using the same button remember the button Press hold 2 5 seconds Release for 2 5 seconds Press hold 2 5 seconds Release for 2 5 seconds Press hold 2 5 seconds 3 If this test mode has been entered successfully all indicators on the console are illuminated for 5 sec...

Page 2: ...lluminated to indicate the airflow range corresponding to the number displayed The More LED will be illuminated for airflow readings above 40 cfm The Normal LED will be illuminated for airflow readings between 29 and 40 cfm The Less LED will be illuminated for airflow readings less than 29 cfm If airflow value is low check to make sure the lint screen is clean the door seal is in place and the ven...

Page 3: ...re the lint screen is clean the door seal is in place and the vent is not obstructed DISPLAY FAULT CODES The fault codes below would be indicated when attempting to start a drying cycle or after activating the diagnostic test mode PROBLEM POSSIBLE CAUSE TEST NOTE Possible Cause Tests MUST be performed in the sequence shown for each problem WON T POWER UP No response when buttons are pressed 1 Supp...

Page 4: ...INE CONTROL ELECTRONICS P4 2 P4 1 R R INLET THERMISTOR 50k Ω INLET TEMP INLET TEMP RTN BU P8 1 LAMP LOAD P8 2 GND CENTRIFUGAL SWITCH 2M 1M 5M 6M 3M R LINE L2 W DOOR SWITCH W NEUTRAL N T BU BU W W P8 4 P8 3 NEUTRAL P9 1 P8 5 BK W THERMAL FUSE 196 F 91 C 4M DRIVE MOTOR 1 3 H P MAIN 1 4 2 6 Ω START 1 4 2 8 Ω SENSOR DOOR NEUTRAL MOTOR MTR CS MOIST MOIST RTN MODEL MODEL RTN OUTLET TEMP OUTLET TEMP RTN ...

Page 5: ...W BK THERMAL CUT OFF 309 F 154 C HEATER 2700 W G Y R 240 VOLTS HEATER RELAY 1 HEATER RELAY 2 COM BK BK HEATER 2700 W R V INLET TEMP INLET TEMP RTN P4 3 P4 6 R R 10k Ω P4 2 P4 1 R R 50k Ω EXHAUST THERMISTOR INLET THERMISTOR NC HIGH LIMIT THERMOSTAT 180 F 82 C V R HEATER DUAL ELEMENT STRIP CIRCUIT CENTRIFUGAL SWITCH 2M 1M 5M 6M 3M W DOOR SWITCH T BU BU W P8 4 P9 1 THERMAL FUSE 196 F 91 C 4M DRIVE MO...

Page 6: ...s test is used to determine if power is present at the machine control electronics NOTE The drum light is controlled by the machine control on all models 1 Plug in dryer or reconnect power 2 Open the door If the drum light illuminates then power is present at the machine control Go to TEST 6 page 10 If the drum light fails to illuminate do not assume the machine control electronics needs replaceme...

Page 7: ...TS OF MEASUREMENT MAIN 1 4 2 6 Blue wire in back at pin 4 and bare copper wire on pin 5 of black drive motor switch START 1 4 2 8 Blue wire in back at pin 4 and bare copper wire on pin 3 of black drive motor switch If the resistance at the motor is correct there is an open circuit between the motor and machine control electronics Check for failed belt switch If the Start winding resistance is much...

Page 8: ...ted go to step 7 If an open circuit is detected go to step 6 6 Visually check the wire connections to the heater If the connections look good replace the heater 7 Measure the resistance at the heater between the violet wire and the red wire terminals If an open circuit is not detected go to step 9 If an open circuit is detected go to step 8 8 Visually check the wire connections to the heater If th...

Page 9: ...0 61 2 63 7 131 55 14 6 15 3 77 25 49 0 51 0 140 60 12 1 12 8 86 30 39 5 41 1 149 65 10 2 10 7 95 35 32 0 33 3 158 70 8 5 9 0 104 40 26 1 27 2 167 75 7 2 7 6 113 45 21 4 22 3 176 80 6 1 6 5 122 50 17 6 18 5 The table above shows the resistance values that should be observed for the various temperatures at the heater assembly If the thermistor resistance does not agree with the measurements in the ...

Page 10: ...5 connector is inserted all the way into the machine control electronics If visual check passes replace the user interface assembly 2 Plug in dryer or reconnect power 3 Perform the Console Buttons and Indicators Diagnostic test page 1 to verify repair 4 If replacing the user interface assembly failed Unplug dryer or disconnect power Replace the machine control electronics Plug in dryer or reconnec...

Page 11: ...the Machine Control Electronics 3 Remove the wire connections to the machine control assembly 4 Remove the one screw holding the machine control assembly to the metal bracket See figure 14 5 Push in on the tab located on the back of the machine control to slide it off the bracket Removing the User Interface Assembly 3 Remove the wire connections from the user interface assembly including the P5 ri...

Page 12: ...n reconnecting wire connections be sure to route the user interface wires beneath the retainer clips on the user interface back cover REMOVING THE BACK PANEL 1 Unplug dryer or disconnect power 2 Remove the cover plate screw and cover plate See figure 17 3 Remove the nine rear screws from the back panel then remove panel Cover Plate Screw Cover Plate Figure 17 Remove screws Locking Tabs User Interf...

Reviews: