Electrical Requirements – U.S.A.

Q

It is recommended that a separate circuit breaker serving only this 
appliance be provided.

Q

  To minimize possible shock hazard, the cord must be plugged 

into a mating, 3- or 4-prong, grounding-type outlet, grounded 
in accordance with local codes and ordinances. If a mating 
outlet is not available, it is the personal responsibility and  
obligation of the customer to have the properly grounded 
outlet installed by a qualified electrician.

Q

  If codes permit and a separate ground wire is used, it is  

recommended that a qualified electrician determine that  
the ground path is adequate. 

Q

Check with a qualified electrician if you are not sure the 
washer is properly grounded.

Q

  Do not have a fuse in the neutral or ground circuit.

It is your responsibility:

Q

  To contact a qualified electrical installer.

Q

  To be sure that the electrical connection is adequate and in  

conformance with the National Electrical Code, ANSI/NFPA 
70-latest edition and all local codes and ordinances.

 

A copy of the above code standards can be obtained from:  
National Fire Protection Association, One Batterymarch Park, 
Quincy, MA 02269.

Q

  To supply the required 3 or 4 wire, single phase, 120/240 volt,  

60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt 
electrical supply, if specified on the serial/rating plate) on a 
separate 30-amp circuit, fused on both sides of the line. A 
time-delay fuse or circuit breaker is recommended. Connect  
to an individual branch circuit. 

Q

  Do not use an extension cord.

Electrical Connection

To properly install your washer/dryer, you must determine the 
type of electrical connection you will be using and follow the 
instructions provided for it here.

Q

  This washer/dryer is manufactured ready to install with a 

3-wire electrical supply connection. The neutral ground wire is 
permanently connected to the neutral conductor (white wire) 
within the dryer. If the dryer is installed with a 4-wire electrical 
supply connection, the neutral ground wire must be removed 
from the external ground connector (green screw), and 
secured under the neutral terminal (center or white wire) of the  
terminal block. When the neutral ground wire is secured under 
the neutral terminal (center or white wire) of the terminal block, 
the dryer cabinet is isolated from the neutral conductor.

Q

  If local codes do not permit the connection of a neutral ground 

wire to the neutral wire, see “Optional 3-wire connection” in 
the “Electrical Connection” section.

Q

  A 4-wire power supply connection must be used when the  

appliance is installed in a location where grounding through 
the neutral conductor is prohibited. Grounding through the 
neutral is prohibited for (1) new branch-circuit installations,  
(2) mobile homes, (3) recreational vehicles, and (4) areas  
where local codes prohibit grounding through the neutral 
conductors.

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with 
clothes dryers. The kit should contain:

Q

  A UL listed 30-amp power supply cord, rated 120/240 volt  

minimum. The cord should be type SRD or SRDT and be at 
least 4 ft (1.22 m) long. The wires that connect to the dryer 
must end in ring terminals or spade terminals with upturned 
ends.

Q

  A UL-listed strain relief.

4-wire 

receptacle 

(14-30R)

3-wire 

receptacle 

(10-30R)

 Then choose a 4-wire power supply cord with ring 
or spade terminals and UL-listed strain relief. The 
4-wire power supply cord, at least 4 ft (1.22 m) 
long, must have four 10-gauge copper wires and 
match a 4-wire receptacle of NEMA Type 14-30R. 
The ground wire (ground conductor) may be either 
green or bare. The neutral conductor must be 
identified by a white cover.

 Then choose a 3-wire power supply cord with ring 
or spade terminals and UL-listed strain relief. The 
3-wire power supply cord, at least 4 ft (1.22 m) long, 
must have three 10-gauge copper wires and match 
a 3-wire receptacle of NEMA Type 10-30R.

If your outlet looks like this:

If your outlet looks like this:

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) 
and be:

Q

   Flexible armored cable or nonmetallic sheathed copper  

cable (with ground wire), covered with flexible metallic 
conduit. All current-carrying wires must be insulated.

Q

   10-gauge solid copper wire (do not use aluminum).

Q

   At least 5 ft (1.52 m) long.

Summary of Contents for W10761048A

Page 1: ...EUSE SÉCHEUSE 34 EXIGENCES D INSTALLATION 36 Outillage et pièces 36 EXIGENCES D EMPLACEMENT 38 DIMENSIONS DISTANCES DE DÉGAGEMENT 39 SYSTÈME DE VIDANGE 41 SPÉCIFICATIONS ÉLECTRIQUES CANADA 42 ENLEVER LA SANGLE D EXPÉDITION 43 INSTALLATION DES PIEDS DE NIVELLEMENT 44 ENLEVER L EMBALLAGE EN MOUSSE modèles de 24 44 ÉVACUATION 45 Exigences concernant l évacuation 45 Planification du système d évacuati...

Page 2: ...2 Washer Dryer Safety IMPORTANT When discarding or storing your old clothes dryer remove the door ...

Page 3: ...3 ...

Page 4: ...Flat blade screwdriver 2 Phillips screwdriver Adjustable wrench that opens to 1 25 mm or hex head socket wrench 1 4 nut driver recommended Wire stripper Caulking gun and compound new vent installations Utility knife Tin snips new vent installations Tools and Parts Gather required tools and parts before starting installation Installation Requirements Drain hose Shipping strap 27 models Not in parts...

Page 5: ...2 4 m Drain hose too short Extension Drain Hose Part Number 285863 Connector Kit Part Number 285835 Lint clogged drain Drain Protector Part Number 367031 Connector Kit Part Number 285835 Water faucets 2 longer water fill hoses beyond reach 6 ft 1 8 m Part Number 76314 of fill hoses 10 ft 3 0 m Part Number 350008 Inlet hoses with flat washers Q Vent clamps Q Vent elbows and ductwork Check local cod...

Page 6: ...rs Contact your local building inspector Recessed area or closet installation The spacing dimensions above are recommended for this washer dryer This washer dryer has been tested for spacing of 0 0 mm clearance on the sides Recommended spacing should be considered for the following reasons Q Additional spacing should be considered for ease of installation and servicing Q Additional clearances migh...

Page 7: ...587 8 1495 mm 26 660 mm 1 25 mm 32 813 mm 321 8 816 mm 653 4 1670 mm 34 864 mm 713 4 1822 mm 271 4 692 mm 1 25 mm Dimensions Clearances Side Clearances recommended minimum 1 0 25 mm 0 mm 1 0 25 mm 0 mm 5 127 mm 12 305 mm 1 25 mm Closet Dimensions Clearances 27 Models Front Back Top Clearances Front View Back View Side View ...

Page 8: ...4 356 mm 1 25 mm 26 660 mm 271 2 699 mm 703 4 1797 mm 357 8 911 mm 201 2 521 mm 1 25 mm 267 8 683 mm 303 4 781 mm 653 4 1670 mm 37 940 mm 703 4 1797 mm 237 8 606 mm 1 25 mm Dimensions Clearances Side Clearances recommended minimum 1 0 25 mm 0 mm 1 0 25 mm 0 mm 5 127 mm 12 305 mm 1 25 mm Closet Dimensions Clearances 24 Models Front Back Top Clearances Front View Back View Side View ...

Page 9: ...Floor drain system requires a Siphon Break Kit Part Number 285834 2 Connector Kits Part Number 285385 and an Extension Drain Hose Part Number 285863 that may be purchased separately To order please see toll free phone numbers in your Use and Care Guide Minimum siphon break 28 710 mm from bottom of washer dryer Additional hoses may be needed Laundry tub drain system Minimum capacity 20 gal 76 L Top...

Page 10: ...or green screw and secured under the neutral terminal center or white wire of the terminal block When the neutral ground wire is secured under the neutral terminal center or white wire of the terminal block the dryer cabinet is isolated from the neutral conductor Q If local codes do not permit the connection of a neutral ground wire to the neutral wire see Optional 3 wire connection in the Electri...

Page 11: ...l supply on a separate 30 amp circuit fused on both sides of the line A time delay fuse or circuit breaker is recommended Connect to an individual branch circuit Q This dryer is equipped with a CSA International Certified Power Cord intended to be plugged into a standard 14 30R wall receptacle The cord is 5 ft 1 52 m long Be sure wall receptacle is within reach of dryer s final location 4 wire rec...

Page 12: ...ee movement This is required for proper leveling Gently lower the washer dryer to the floor 1 Remove strap hang tag and pin 2 Check rear leveling legs Remove Shipping Strap 27 models To avoid floor damage set washer dryer onto cardboard before moving across floor Move washer dryer close to its final location Cut the shipping strap about 16 406 mm from the plug end Look for the words CUT HERE Disca...

Page 13: ...rdboard from the shipping carton Gently place the washer dryer on its side on the cardboard 1 Install rear leveling legs Push legs into holes in rear corners until they snap into place Check adjustability of rear legs by pushing in one leg The other leg should come out Check both legs If they do not move freely repeat procedure 2 Install front leveling legs Examine front leveling legs find diamond...

Page 14: ...nting Requirements Power supply cord 3 wire receptacle NEMA Type 10 30R Go to 3 wire Power Supply Cord Connection section Then go to Venting Requirements NOTE If local codes do not permit connection of a cabinet ground conductor to neutral wire go to Optional 3 wire Connection section This connection may be used with either a power supply cord or a direct wire connection A B C D E F 2 Remove termi...

Page 15: ...her Power Supply Cord Strain Relief 4 Wire Power Supply Cord Connection Remove center terminal block screw B Remove neutral ground wire E from external ground conductor screw A E B A 1 Prepare to connect neutral ground wire and neutral wire E B C 2 Connect neutral ground wire and neutral wire Connect neutral ground wire E and neutral wire white or center C of power supply cord under center termina...

Page 16: ...es to outer terminal block screws Tighten screws Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 2 Connect neutral wire Connect neutral wire white or center C of power supply cord to center terminal block screw B Tighten screw B C Remove center terminal block screw B B 1 Remove center screw A F Connect grou...

Page 17: ... Attach direct wire strain relief Put direct wire cable through the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Tighten strain relief screw against the direct wire cable 2 Attach direct wire cable to strain relief Direct Wire Strain Relief Direct wire cable must have 5 ft 1 52 m of extra length so washer dryer may be moved if neede...

Page 18: ...t of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 5 Connect remaining wires B E C 3 Connect neutral ground wire and neutral wire Connect neutral ground wire E and place hooked end hook facing right of neutral wire white or center wire C of direct wire cable under center screw of terminal block B Squeeze hooked ends together and tighten screw Direct wire cable m...

Page 19: ...ew A to an adequate ground Finally reinsert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements IMPORTANT You must verify with a qualified electrician that this grounding method is acceptable before connecting 4 Connect remaining wires Place hooked ends of remaining direct wire cable wires under outer terminal block screws hook...

Page 20: ...4 wire Power Supply Cord Connection section Then go to Venting Requirements 3 wire direct connection Go to 3 wire Direct Wire Connection section Then go to Venting Requirements 4 wire direct connection Go to 4 wire Direct Wire Connection section Then go to Venting Requirements Power supply cord 3 wire receptacle NEMA Type 10 30R Go to 3 wire Power Supply Cord Connection section Then go to Venting ...

Page 21: ...Strain relief tab pointing down Put power supply cord through the strain relief Be sure that the wire insulation on the power supply cord is inside the strain relief The strain relief should have a tight fit with the dryer cabinet and be in a horizontal position Do not further tighten strain relief screws at this point 2 Attach power supply cord to strain relief 4 wire Power Supply Cord Connection...

Page 22: ... other wires to outer terminal block screws Tighten screws Tighten strain relief screws Insert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requirements 2 Connect ground wire A B C D E A B C D E F 3 wire receptacle NEMA type 10 30R 3 prong plug Spade terminals with upturned ends Ring terminals Use where local codes permit connecting ...

Page 23: ...e cable to strain relief 3 wire direct connection Go to 3 wire Direct Wire Connection 4 wire direct connection Go to 4 wire Direct Wire Connection on this page If your wiring looks like this 4 wire Direct Wire Connection IMPORTANT A 4 wire connection is required for mobile homes and where local codes do not permit the use of 3 wire connections Direct wire cable must have 5 ft 1 52 m of extra lengt...

Page 24: ... wire green or bare of direct wire cable F 3 4 19 mm UL listed strain relief D E F A C B Place the hooked ends of the other direct wire cable wires under the outer terminal block screws hooks facing right Squeeze hooked ends together Tighten screws Tighten strain relief screw Insert tab of terminal block cover into slot of dryer rear panel Secure cover with hold down screw Now go to Venting Requir...

Page 25: ...ply cord where local codes do not permit connecting cabinet ground conductor to neutral wire 1 Connect neutral ground wire and neutral wire Remove center terminal block screw Remove neutral ground wire from external ground conductor screw Connect neutral ground wire and the neutral wire white or center wire of power supply cord cable under center terminal block screw Tighten screw A Neutral wire w...

Page 26: ... Q Do not install in enclosed walls ceilings or floors Q The total length should not exceed 73 4 ft 2 4 m NOTE If using an existing vent system clean lint from entire length of the system and make sure exhaust hood is not plugged with lint Replace plastic or metal foil vents with rigid metal or flexible metal vents Review Vent System Chart and if necessary modify existing vent system to achieve be...

Page 27: ... visit us at www applianceaccessories com In Canada call 1 800 807 6777 or visit us at www whirlpoolparts ca Part Number Descriptions 4396028 Over the Top Installation 4396037 0 0 mm to 18 457 mm Metal vent periscope For use with dryer vent to wall vent mismatch 4396011 18 457 mm to 29 737 mm Metal vent periscope For use with dryer vent to wall vent mismatch 4396014 29 737 mm to 50 1 27 m Metal ve...

Page 28: ...urns as possible Determine vent length and elbows needed for best drying performance Q Use following Vent System Chart to determine type of vent material and hood combinations acceptable to use NOTE Do not use vent runs longer than those specified in Vent System Chart Exhaust systems longer than those specified will Q Shorten life of dryer Q Reduce performance resulting in longer drying times and ...

Page 29: ...14 mm Drain hose form Open clamp Twist hose back and forth while pushing onto drain connector on the side of the washer dryer Continue until hose contacts the ribbed stops on the cabinet Place clamp over the area marked CLAMP Release clamp 2 Attach drain hose to drain connector 27 model shown Proper connection of the drain hose protects your floors from damage due to water leakage To keep the drai...

Page 30: ...cold water faucet IMPORTANT Do not overtighten or use tape or sealants on valve when attaching to faucets or washer Damage can result HELPFUL TIP Make note of which hose is connected to hot water to help in attaching hoses to washer correctly In most standard configurations hoses will cross over each other when attached correctly 2 Connect inlet hoses to water faucets 4 Connect inlet hoses to wash...

Page 31: ...onnect Vent 1 Connect vent to exhaust outlet 27 model shown 2 Move washer dryer to final location Using a 4 102 mm clamp connect vent to exhaust outlet in dryer If connecting to existing vent make sure vent is clean Dryer vent must fit over dryer exhaust outlet and inside exhaust hood Check that vent is secured to exhaust hood with a 4 102 mm clamp Move washer dryer to final location taking care n...

Page 32: ...s of washer dryer and repeat as needed With washer dryer in its final location place a level on top edges of washer dryer Use side seam as a guide to check levelness of sides Check levelness of front using lid as shown Rock washer dryer back and forth to make sure all four feet make solid contact with floor If washer dryer is level skip to step 3 27 models or step 4 24 models 1 Check levelness of ...

Page 33: ...horoughly with a damp cloth to remove any dust T To test the washer measure 1 2 the normal recommended amount of detergent and pour it into the washer Close the lid Select HEAVY and pull out the Cycle Control knob Allow the washer to complete one whole cycle T To test the dryer set the dryer on a full heat cycle not an air cycle for 20 minutes and start the dryer If the dryer will not start check ...

Reviews: