background image

A. Downdraft vent
B. Cooktop

C. Measurement of cooktop rear 

overhang.

D. D = Measurement of cooktop rear 

overhang (C) + 1

¹³⁄₁₆

" [46.2 mm] (E)

E. 1

¹³⁄₁₆

" (46.2 mm)

F. ½" (12.7 mm) minimum

G. ¼" (6.4 mm) minimum
H. Countertop and backsplash

I. ½" (12.7 mm) minimum

A

B

C

E

H

D

I

G

F

30" (76.2 cm) and 36" (91.4 cm) Retractable (Pop-Up) Downdraft Vent System

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10342491C

2/8/2012

Page 1 of 3

COUNTERTOP CUTOUT DIMENSIONS

PRODUCT MODEL NUMBERS

PRODUCT DIMENSIONS

UXD8630DY

UXD8636DY

Electrical

A 120 Volt, 60 Hz., AC only 15-amp fused, electrical circuit is required.

Top trim widths:
30" (76.2 cm)
36" (91.4 cm) 

13¹⁄₂

" (34.3 cm) 

retractable 
vent height

27" (68.6 cm) for 30" (76.2 cm) vent
33" (83.8 cm) for 36" (91.4 cm) vent

16

¹⁄₂

" (42.0 cm)

10"

(25.4 cm)

2

¹⁄₈

" (5.4 cm)

28

¹⁄₂

"

(72.4 cm)

³⁄₈

" (0.95 cm)

1

¹⁄₂

" (3.8 cm)

13

¹⁄₈

" (33.4 cm)

5

¹⁄₄

"(13.3 cm) 

for 30" (76.2 cm) vent
8

¹⁄₄

"(21.0 cm) 

for 36" (91.4 cm) vent

³⁄₄

(1.9 cm)

LOCATION REQUIREMENTS

NOTE:

Downdraft vent is installed directly behind the cooktop. Install the

downdraft vent first, then install the cooktop.

IMPORTANT:

Observe all governing codes and ordinances.

● 

Have a qualified technician install the downdraft vent. It is the installer’s

responsibility to comply with installation clearances specified on the

model/serial rating plate. The model/serial rating plate is located on the front of

the downdraft vent above the terminal box cover. 

● 

Downdraft vent location should be away from strong draft areas, such as

windows, doors, and strong heating vents or fans.

● 

Cabinet opening dimensions that are shown must be used. Given dimensions

provide minimum clearance.

● 

Consult the cooktop manufacturer installation instructions before making any

cutouts.

Check that the downdraft vent and cooktop location will clear the

cabinet walls, backsplash, and rear wall studs inside the cabinet.
Check for the minimum distance between the front edge of the

countertop and the front edge of the cooktop. The minimum horizontal

distance between the overhead cabinets is the same as the width of the

installed downdraft vent.

● 

All openings in ceiling and wall where the downdraft vent will be installed must

be sealed.

● 

Grounded electrical outlet is required. See “Electrical Requirements” section.

● 

When installing the downdraft vent, the cabinet drawer will need to be removed

and the drawer front installed permanently to the cabinet.

Cabinet Construction:

Downdraft vent is designed for use in a cabinet with a depth of 24" (61 cm).

Some installations require a countertop deeper than 25" (63.5 cm). See the

Countertop Cutout Dimensions section.
The maximum depth of the overhead cabinet is 13" (33 cm). Overhead cabinets

installed at either side of the downdraft vent must be 18" (45.7 cm) above the

cooking surface.

For Mobile Home Installations

The installation of this range hood must conform to the Manufactured Home

Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal

Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or

when such standard is not applicable, the standard for Manufactured Home

Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI

A225.1/NFPA 501A*, or latest edition, or with local codes.

A=

¹⁄₂

" (12.7 mm)

minimum

   21

⁵⁄₁₆

"

(54.1 cm)

Cutouts are
for 3

¹⁄₄

" x 10"

(8.3 x 25.4 cm)
rectangular or 6" 
(15.2 cm) round
vent system.

Centerline of cooktop cutout

   21⁵⁄₁₆

"

(54.1 cm)

Locate power 
supply junction 
box at lower 
left hand 
rear corner 
of the cabinet.

10

" (25.4 cm)

NOTES:

● 

See cooktop manufacturer’s instructions for cooktop cutout depth and width.

● 

Use dimensions for vent system cutout location that applies to your

installation.

● 

Interior mounted blower systems connect with 3

¹⁄₄

" x 10" (8.3 x 25.4 cm)

rectangular or 6" (15.2 cm) round vent system. The cutout locations for this

vent system will depend on your specific installation.

CABINET DIMENSIONS

IMPORTANT: 

Countertops with a bull-nosed front edge are not

recommended for these installations.

● 

Some models require a countertop deeper than 25" (63.5 cm); see
the following Countertop Cutout Dimensions section.

● 

To avoid mistakes, it is recommended that the cooktop and vent
cutouts be drawn on the countertop before making any cutouts.

● 

See Cooktop Installation Instructions for complete cutout
dimensions, location dimensions and installation details.

Reviews: