background image

7

FIG. 9

Clamp

(2 - not

included)

Ground Wire

(not included)

GROUNDING INFORMATION

(for Installations on Metal Pipe)

The house main incoming water pipe is often

used to ground electrical outlets in the home.

Grounding protects you from electrical shock.

Installing the water filtration system may break

this ground.  Before beginning installation, pur-

chase and securely install two grounding clamps

and a #4 copper wire across the location where

the filter will be, tightly clamping it at both ends,

as shown below.

Installation Instructions

In the state of Massachusetts: The Commonwealth

of Massachusetts plumbing code 248-CMR shall

be adhered to.  A licensed plumber shall be used

for this installation.

PLUMBING CODES

All plumbing must be completed in accordance with

national, state and local plumbing codes.  Local code

information can be obtained at your local public works

department.

ALWAYS INSTALL THE FILTER UPRIGHT

To operate properly, the UltraEase™ Pivotal Whole

Home Water Filtration System must be installed in a

vertical orientation.  The filtration system must also be

installed with the water flow following the arrows on

the filter’s inlet and outlet.  This corresponds to a left-

to-right flow, when looking at the front of the filter head

assembly (See Fig. 7).  Leave a few inches of space

under the filter sump to allow it to be grasped, pivoted

up and removed when changing filter cartridges, as

shown in the “Filter Cartridge Replacement” section.

MOUNTING BRACKET

A metal bracket is included with the UltraEase™

Pivotal Whole Home Water Filtration System to sup-

port the assembled filter and plumbing when neces-

sary.  The bracket should be installed before the filter

is connected to the plumbing.
The bracket may be mounted to a wall or wall framing

member with two screws (included), as shown in

Figure 6.  These screws, or other (not included) fas-

teners, if used, must be mounted into a stable surface,

strong enough to support the weight of the filter,

plumbed and full of water - about 15 pounds.
The back of the filter head housing clips onto the

bracket.  When mounted, the filter should be aligned

with the inlet and outlet plumbing, and not cause rigid

pipes to distort.

CONNECT THE VENT TUBE

Each time you replace a filter cartridge, the filter will be

placed into the bypass position by pivoting it outward

(shown in the “Filter Cartridge Replacement” section).

Whenever this is done, water pressure inside the

sump is relieved, and about 4 ounces of water will be

expelled through the vent port.  Always install the

included vent tube on this barbed fitting to carry the

water to a floor drain, laundry tub or other suitable

drain point.  See Figure 8.

NOTE:

This vent tube works by gravity.  Do not ele-

vate it above the vent port.  Route it downward to the

drain point with no humps, dips or loops.

Properly discard (or recycle) all packing materials.

Electrical Shock Hazard

Prior to installation on metallic plumbing,

securely install two grounding clamps and a

#4 copper wire per installation instructions.
Failure to follow these instructions can result

in death or electrical shock.

Summary of Contents for UltraEase WHAWH90

Page 1: ...em tested and certified by NSF International against NSF ANSI Standard 42 for particulate class III reduction If you have any questions or concerns when installing operating or maintaining your water filtration system call our toll free number 1 866 986 3223 Monday Friday 8 AM 7 PM EST or visit whirlpoolwatersolutions com When you call please be prepared to provide the model number and date code o...

Page 2: ...anning the Installation 5 Typical Installation Illustrations 6 Installation Instructions 7 Always Install the Filter Upright 7 Mounting Bracket 7 Plumbing Codes 7 Connect the Vent Tube 7 Grounding Information 7 Filter Cartridges 8 9 Filter Cartridge Life 8 Filter Cartridge Replacement 8 9 Troubleshooting the System 9 Warranty 10 Exploded View Parts List 11 Outlet 1 NPT Inlet 1 NPT 14 5 1 4 ...

Page 3: ...te disinfection before or after the system While testing was performed under standard laboratory conditions actual performance of the system may vary based on local water conditions Some or all of the contami nants reduced by this unit may not be in your water supply See elsewhere in this manual for further instructions on system installation operating proce dures filter cartridge replacement and ...

Page 4: ...0 shall be adhered to Consult with your licensed plumber q Do not use with water that is microbiologically unsafe or of unknown quality without adequate dis infection before or after the system q The UltraEase Pivotal Whole Home Water Filtration System works on water pressures of 30 Packing List Installation Adaptors Vent Tube Mounting Bracket with Screws Clips FIG 2 The parts required to assemble...

Page 5: ... Untreated Water to Outside Faucets Cold Water to House Hot Water to House Water Heater Water Softener Whole Home Filtration System FIG 3B Well Water Supply Pressure Tank Well Pump Untreated Water to Outside Faucets Cold Water to House Hot Water to House Water Heater Water Softener Whole Home Filtration System OR In some cases it may be necessary for plumbing to cross over to ensure the correct fl...

Page 6: ...t before connecting to plumbing Allow at least a few inches of space under the sump to grasp and pivot it outward when replacing filter cartridge Route the vent tube down to a floor drain laundry tub or other suitable drain point Press end of vent tube firmly over barbed fitting Vent port barbed fitting FIG 5 Installation Adaptor with 2 o rings Clip Clip Installation Adaptor with 2 o rings Sump Fi...

Page 7: ...ement section MOUNTING BRACKET A metal bracket is included with the UltraEase Pivotal Whole Home Water Filtration System to sup port the assembled filter and plumbing when neces sary The bracket should be installed before the filter is connected to the plumbing The bracket may be mounted to a wall or wall framing member with two screws included as shown in Figure 6 These screws or other not includ...

Page 8: ...all amount of water approximately 4 ounces is expelled into the vent tube to relieve pressure in the sump 2 Pull the sump downward out of the head NOTE To avoid unintended water flow from the filter head do not pivot filter head down to the serv ice position without the sump and replacement filter cartridge in place as shown in Figure 16 3 It is recommended to take the sump assembly to a sink or l...

Page 9: ...service position 12 Some types of filter cartridges contain activated carbon a black powder Open a faucet down stream from the filter to purge air and fine carbon particles from the cartridge Flush for at least 5 minutes FIG 16 Pivot sump down to service position Insert ports and push sump up into filter head until seated Remove protective caps from filter cartridge ports 8 Filter cartridges can o...

Page 10: ...is warranty applies only while this product is in use in the United States or Canada General Provisions The above warranties are effective provided the UltraEase Pivotal Whole Home Water Filtration System is operated at water pressures not exceeding 100 psi and at water temperatures not exceeding 100 F provided further that the UltraEase Pivotal Whole Home Water Filtration System is not subject to...

Page 11: ...or Kit includes Key Nos 4 5 4 á Installation Adaptor Elbow 1 NPT including o rings 2 5 á Clip 2 6 1042 32 HD Lid Clamp Assembly 7 WHARF90 Repl Filter Cartridge Ù 8 1042 32 HC Sump 9 1042 32 47 Vent Tube 6 ft long 1042 32 AD Owner s Manual To order repair parts call toll free 1 866 986 3223 Monday Friday 8 am 7 pm EST Ù Please purchase replacement cartridges from the retailer where you bought your ...