background image

22

Basic 

Troubleshooting

Summary of Contents for SIA120 IN

Page 1: ...Product Introduction for Whirlpool Inverter Plus Split Type Air Conditioner SIA90 IN SIA120 IN SIA180 IN SIA240 IN ...

Page 2: ...acity in HP Cooling Capacity in BTU Cooling Capacity in kJ hr Selling Price SIA90IN SIA90CO 1 0 HP 9 000 10 023 Php 31 998 SIA120IN SIA120CO 1 5 HP 12 000 13 188 Php 34 998 SIA180IN SIA180CO 2 0 HP 18 000 18 990 Php 45 998 SIA240IN SIA240CO 2 5 HP 22 000 23 210 Php 52 998 ...

Page 3: ... Compressor Brand GMCC Toshiba Highly Hitachi QINGAN Highly Hitachi Refrigerant Type R410A R410A R410A R410A Power Supply V Hz 220 60 220 60 220 60 220 60 Cooling Load Calculation in m 9 18 15 25 20 36 25 50 Refrigerant Charge volume in kg for 5 meters 0 72 0 88 1 27 1 85 Additional Charge per meter of piping in grams 20 20 20 20 ...

Page 4: ... in psi 2900 75 2900 75 2900 75 2900 75 Sealed System Operating Pressure in psi Discharge Side 116 61 116 61 116 61 116 61 Suction Side 443 90 443 9 443 9 443 9 Compressor Type Rotary Rotary Rotary Rotary Indoor liquid tube diameter in inches 1 4 1 4 1 4 3 8 Indoor gas tube diameter in inches 3 8 3 8 1 2 5 8 ...

Page 5: ...cations Indoor Model No SIA90IN SIA120IN SIA180IN SIA240IN Indoor tubes in meters 5 5 5 5 Min connection pipe length in meter 3 3 3 3 Max connection pipe length in meter 10 10 10 10 Max height difference in meter 5 5 5 5 ...

Page 6: ... Model No SIA90IN SIA120IN SIA180IN SIA240IN Dimensions In mm In inches In mm In inches In mm In inches In mm In inches H 270 10 75 270 10 75 320 12 75 320 12 75 W 790 31 25 790 31 25 1020 40 25 1020 40 25 D 205 8 25 205 8 25 215 8 5 215 8 5 ...

Page 7: ...or Model No SIA90CO SIA120CO SIA180CO SIA240CO Dimensions In mm In inches In mm In inches In mm In inches In mm In inches H 550 21 75 550 21 75 602 23 75 860 34 W 780 30 75 780 30 75 780 28 700 27 75 D 270 10 75 270 10 75 270 10 75 320 12 75 ...

Page 8: ...lation Rate 7 200 7 200 8 200 8 200 Additional Cost in excess of 10ft foot 225 275 325 325 Recommended Floor Area Up to 18 19 24 25 31 32 45 Liquid Pipe in inches 1 4 1 4 1 4 3 8 Suction Pipe in inches 3 8 3 8 1 2 5 8 Max Piping Length in meters 10 10 10 10 Max Elevation Diff in meters 5 5 5 5 ...

Page 9: ...t within Metro Manila primary provincial and secondary cities Succeeding survey will be charge at Php 400 00 per visit Transportation fee of Php 300 00 will be charge to customer if installation outside Metro Manila Primary provincial and secondary cities Transportation fee will be deducted from total installation cost Php 300 00 Nationwide coverage of installation program Installation rates are s...

Page 10: ...5 Electrical Box 6 Emergency Control button 7 Vertical Adjustment Louver Inside 8 Horizontal Adjustment Louver 9 Air Filter 10 Remote Control Outdoor 11 Air Intake 12 Pipes and Power Connection Cord 13 Drain Hose Optional Note Condensate water drains at COOLING or DRY operation 14 Air Outlet ...

Page 11: ...operation Displays purple light under FAN ONLY operation Temperature Indicator Displays set temperature and room temperature Default temperature showing is room temperature It shows set temperature under the settings by using remote controller then back to show room temperature after a few seconds ...

Page 12: ...n as shown 2 Hold the two sides of the cover and press to let the cover deform a little bit at the same time press down the caudal of cover as shown to open it 3 Insert 2 AAA batteries 1 5V into the compartment Ensure that and polarity is correctly positioned 4 Close the battery cover on the remote control Battery Location ...

Page 13: ...ense operation 7 Swing Button 8 Sleep Button 9 Accurate Button Used to set the temperature at the decimal digits 10 Dry Button 11 Fan Only Button 12 Turbo Button 13 Clock Button 14 Timer Button 15 Hour Button 16 Minute Button 17 Lock Button Used to lock or unlock the buttons 18 Reset Button Back to default setting by pressing this button ...

Page 14: ...14 Remote Control Functions ...

Page 15: ...irectly regardless of the appliance is on or off Under this mode operation mode temperature and fan speed are automatically set based on the actual room temperature Note Temperature fan speed and louver direction can be adjusted You can adjust to your desired settings if you still feel uncomfortable ...

Page 16: ...elated buttons DRY mode 3 Press the DRY button to start the dehumidification operation to reduce the humidity of room SLEEP mode 4 SLEEPmode can be set in 6th Sense Cool or DRYoperation mode This function gives you a more comfortable environment for sleep In SLEEP mode Fan speed is automatically set at silent or low speed Set temperature will be rised by 1 C per hour till up to 28 C ...

Page 17: ...de 6 Press the FAN ONLY button to start or stop fan operation Fan speed and louver direction can be adjusted Note This function can only be activated under the appliance at off status RESET function If remote controller shows error code or can not be used press this button by using a pin to let the remote control back to default settings LOCK function Press the button by using a pin to lock all th...

Page 18: ...he on off swith located on the indoor unit Open the front panel you can find the on off switch at right side press it by a pin Turn on the appliance when the unit is off press this button it will start up and operate in 6th SENSE mode Turn off the appliance when the unit is on press this button the unit will stop working ...

Page 19: ...19 Basic Functional Parts ...

Page 20: ...20 Sensor Location Evaporator Temperature Sensor Actual Room Temperature Ambient Sensor ...

Page 21: ...trols the power supply for the compressor to run accurately based on the Main Board s command The main control board is mainly responsible for outdoor and indoor machine and the communication between modules in the chip containing all the functionality of the air conditioner control program ...

Page 22: ...22 Basic Troubleshooting ...

Page 23: ...23 Basic Troubleshooting ...

Page 24: ... the said parts are damaged it could mean that the program needs to be reset When this happens turn OFF the unit for 5 minutes and then turn it ON again Of the fault code appears for 3 consective operations only then should you consider to replace the part indicated in the error code ...

Page 25: ... ensure that PG motor control circuit device without welding welding control circuit diagram tagging model of device parameters such as resistance voltage measurement if the device is damaged please replace the same type of device Fan motor short running after the F0 which indicates that the motor feedback signal wire broken no feedb ack signal Turn the motor measurement feedback line 1 2 feet wit...

Page 26: ...ate insurance tube fuse Maintenance master control board switching power supply or replace the module board Outdoor switch power failure outdoor main control board diode VD452 dawn Ensure device D101 D107 K101 without welding welding the wel ding if D101 17 feet no output change the main chips If the D101 17 feet normal D107 10 feet without output ULN2003 replacem ent If K101 1 foot control signal...

Page 27: ...ate insurance tube fuse Maintenance master control board switching power supply or replace the module board Outdoor switch power failure outdoor main control board diode VD452 dawn Ensure device D101 D107 K101 without welding welding the wel ding if D101 17 feet no output change the main chips If the D101 17 feet normal D107 10 feet without output ULN2003 replacem ent If K101 1 foot control signal...

Page 28: ...pen To open it Run after a period of time shows that system into the air or the lack of refrigerant Emptying of the refrigerating system or vacuum recharging refrigerant J6 Module board radiating surface temperature is too high Make sure that the wiring harness between compressor module and the radiator not blocked no cracks tighten screw fastening module board in place To ensure that the outdoor ...

Page 29: ...main control board is not deffective A flashing LED 1 indicates a main control failure B When the LED indicator on the compressor module appears fast slow regular flashing it means that the Compressor Module is deffective Compressor Module Main Control Board Compressor Module LED LED 1 LED 2 ...

Page 30: ...30 Thank You ...

Reviews: