background image

Gas Supply Requirements

Observe all governing codes and ordinances.

IMPORTANT:

This installation must conform with all local codes

and ordinances. In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition.

Type of Gas

Natural Gas:

This range is design-certified by the CSA International for use
with natural gas or, after proper conversion, for use with LP gas.

This range is factory set for use with natural gas. See “Gas
Conversions” section. The model/serial rating plate located on
the frame behind the broiler door has information on the types
of gas that can be used. If the types of gas listed do not
include the type of gas available, check with the local gas
supplier.

LP Gas conversion:

Conversion must be done by a qualified service technician. 

No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier. See “Gas
Conversions” section.

Gas Supply Line

Provide a gas supply line of 

³⁄₄

" rigid pipe to the range

location. A smaller size pipe on longer runs may result in
insufficient gas supply. Pipe joint compounds that resist the
action of LP gas must be used. Do not use TEFLON

®†

tape.

With LP gas, piping or tubing size can be 

¹⁄₂

" minimum.

Usually, LP gas suppliers determine the size and materials
used in the system.

WARNING

Explosion Hazard

Use a new CSA International approved gas supply line.

Install a shut-off valve.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure 
gas pressure does not exceed 14" (36 cm) water 
column. 

Examples of a qualified person include: 

licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Electrical Requirements

IMPORTANT: 

The range must be electrically grounded in

accordance with local codes and ordinances, or in the absence 
of local codes, with the National Electrical Code, ANSI/NFPA 70,
latest edition. 

This range is equipped with an electronic ignition system that will
not operate if plugged into an outlet that is not properly polarized.

If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park, Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

Cleveland, Ohio 44131-5575

A 120-volt, 60-Hz, AC-only, 15-amp, fused electrical circuit 
is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this range be provided.

Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that
the outlet provides 120-volt power and is correctly grounded.

This range is equipped with a power supply cord having a 3
prong ground plug. To minimize possible shock hazard, the
cord must be plugged into a mating 3 prong, grounded outlet.

The wiring diagram is located on the back of the range.

NOTE:

The metal chassis of the range must be grounded in order

for the control panel to work. If the metal chassis of the range is
not grounded, no keypads will operate. Check with a qualified
electrician if you are in doubt as to whether the metal chassis of
the range is grounded.

Electrical Shock Hazard

Plug into a grounded 3 prong outlet.

Do not remove ground prong.

Do not use an adapter.

Do not use an extension cord.

Failure to follow these instructions can result in death,
fire, or electrical shock.

WARNING

6

Summary of Contents for SF114PXSB

Page 1: ...IMPORTANT Save for local electrical inspector s use INSTALLATION INSTRUCTIONS 30 76 2 CM FREESTANDING GAS RANGE with standard clean oven W10032050 Table of Contents 2 ...

Page 2: ...mbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING TABLE OF CONTENTS RANGE SAFETY 2 INSTALLATION REQUIREMENTS 4 Tools and Parts 4 Location Requirements 4 Electrical Requirements 6 Gas Supply Requirements 6 ...

Page 3: ... and service must be performed by a qualified installer service agency or the gas supplier Do not use any phone in your building In the State of Massachusetts the following installation instructions apply Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the State of Massachusetts If using a ball valve it shall be a T ha...

Page 4: ...clearances The floor anti tip bracket must be installed To install the anti tip bracket shipped with the range see Install Anti Tip Bracket section Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section Contact a qualified floor covering installer to check that the floor covering can withstand at...

Page 5: ...alling a range hood or microwave hood combination above the range follow the range hood or microwave hood combination installation instructions for dimensional clearances above the cooktop surface 5 For minimum clearance to top of cooktop see NOTE This shaded area recommended for installation of gas pipe This shaded area recommended for electrical outlet 18 45 7 cm min clearance upper side cabinet...

Page 6: ...ersonnel and authorized service personnel Failure to do so can result in death explosion or fire Electrical Requirements IMPORTANT The range must be electrically grounded in accordance with local codes and ordinances or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition This range is equipped with an electronic ignition system that will not operate if plugg...

Page 7: ...valve is for turning on or shutting off gas to the range Gas Pressure Regulator The gas pressure regulator supplied with this range must be used The inlet pressure to the regulator should be as follows for proper operation Natural Gas Minimum pressure 5 WCP Maximum pressure 14 WCP LP Gas Minimum pressure 11 WCP Maximum pressure 14 WCP Contact local gas supplier if you are not sure about the inlet ...

Page 8: ... Anti Tip Bracket Contact a qualified floor covering installer for the best procedure for drilling mounting holes through your type floor covering If the cabinet opening is wider than specified in the Location Requirements section adjust the template so the range will be centered in the cabinet opening 5 To mount the anti tip bracket to a wood floor drill two 1 8 3 2 mm holes at the positions mark...

Page 9: ...e floor Slide the range back so the rear range foot is under the anti tip bracket 2 If installing the range in a mobile home you must secure the range to the floor Any method of securing the range is adequate as long as it conforms to the standards in the Location Requirements section 3 Continue installing your range using the following installation instructions Level Range 1 Place rack in oven 2 ...

Page 10: ... 9 5 mm high If the low flame needs adjusting 1 Turn control knob to the LO setting and remove control knob 2 Insert a small flat blade screwdriver into the valve stem Turn the valve adjusting screw to obtain the smallest flame that will not go out when the control of a cold burner is quickly turned from HI to LO Turn right to decrease flame height Turn left to increase flame height Repeat for oth...

Page 11: ... ignitor do not insert any object into the openings of the protective shield that surrounds the ignitor or clean that area 6 Check the oven burner for proper flame The flame should be 13 mm long with inner cone of bluish green and outer mantle of dark blue and should be clean and soft in character No yellow tips not enough air blowing or lifting too much air of flame should occur If the flame need...

Page 12: ...ve a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so can result in death explosion or fire LP Gas Conversion To Convert Gas Pressure Regulator 1 Ensure that the manual shutoff valve is in the closed position WARNING Tip O...

Page 13: ...he number 56 LP gas spud 6 Place natural gas oven burner spud in plastic parts bag along with natural gas cooktop burner spuds for future use and keep with the bag containing literature 7 Reinstall oven burner 8 Reinstall oven racks oven tray and flame spreader Complete Conversion 1 Refer to the Make Gas Connection section for properly connecting the range to the gas supply 2 Turn the gas manual s...

Page 14: ...nect power 3 Open broiler door and remove broiler pan The gas pressure regulator is located in the back right hand corner of the broiler compartment IMPORTANT Do not remove the gas pressure regulator NOTE Do not remove the spring beneath the cap 4 Remove the cap from the gas pressure regulator using a flat blade screwdriver WARNING Tip Over Hazard A child or adult can tip the range and be killed C...

Page 15: ...emain the same 5 Place LP gas orifice spuds in the plastic parts bag for future use and keep with the bag containing literature 6 Reinstall burners burner caps and burner grates Std burner 149 Std burner 149 Std burner 149 Power burner 165 Complete Conversion 1 Refer to the Make Gas Connection section for properly connecting the range to the gas supply 2 Turn the gas manual shutoff valve to the op...

Page 16: ...W10032050 2006 Whirlpool Corporation All rights reserved Printed in Mexico 07 2006 ...

Reviews: