background image

3

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.

Tools needed

Drill

1

¹⁄₄

" drill bit

¹⁄₈

" (3 mm) drill bit for pilot holes

Pencil

Wire stripper or utility knife

Tape measure or ruler

Caulking gun and weatherproof caulking compound

Flat-blade screwdriver

Phillips screwdriver

For vented installations, you also need:

Saber or keyhole saw

Vent clamps

Metal snips

Compass or 8" (20.3 cm) circle template

Parts supplied

Remove parts from package. Check that all parts are included.

Filter

4 - #10 x 

⁵⁄₈

" mounting screws

7" (17.8 cm) round transition plate

7" (17.8 cm) damper/vent connector

3

¹⁄₄

" x 10" (8.3 x 25.4 cm) damper/vent connector

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

WARNING: 

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK, OR INJURY TO PERSONS, OBSERVE THE 
FOLLOWING: 

■  

Use this unit only in the manner intended by the 
manufacturer. If you have questions, contact the 
manufacturer.

■  

Before servicing or cleaning the unit, switch power off at 
service panel and lock the service disconnecting means to 
prevent power from being switched on accidentally. When 
the service disconnecting means cannot be locked, 
securely fasten a prominent warning device, such as a tag, 
to the service panel.

■  

Installation work and electrical wiring must be done by 
qualified person(s) in accordance with all applicable codes 
and standards, including fire-rated construction.

■  

Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of fuel 
burning equipment to prevent backdrafting. Follow the 
heating equipment manufacturer's guideline and safety 
standards such as those published by the National Fire 
Protection Association (NFPA), the American Society for 
Heating, Refrigeration and Air Conditioning Engineers 
(ASHRAE), and the local code authorities.

■  

When cutting or drilling into wall or ceiling; do not damage 
electrical wiring and other utilities.

■  

Ducted fans must always be vented outdoors.

     

CAUTION: 

For general ventilating use only. Do not use 

to exhaust hazardous or explosive materials and vapors.

     

CAUTION:

 To reduce risk of fire and to properly exhaust 

air, be sure to duct air outside - do not vent exhaust air into 
spaces within walls or ceilings, attics or into crawl spaces, 
or garages.

WARNING:

 TO REDUCE THE RISK OF FIRE, USE ONLY 

METAL DUCTWORK.

WARNING: 

TO REDUCE THE RISK OF A RANGE TOP 

GREASE FIRE:

■  

Never leave surface units unattended at high settings. 
Boilovers cause smoking and greasy spillovers that may 
ignite. Heat oils slowly on low or medium settings.

■  

Always turn hood ON when cooking at high heat or when 
flambeing food (i.e. Crepes Suzette, Cherries Jubilee, 
Peppercorn Beef Flambé).

■  

Clean ventilating fans frequently. Grease should not be 
allowed to accumulate on fan or filter.

■  

Use proper pan size. Always use cookware appropriate for 
the size of the surface element.

WARNING: 

TO REDUCE THE RISK OF INJURY TO 

PERSONS IN THE EVENT OF A RANGE TOP GREASE 
FIRE, OBSERVE THE FOLLOWING:

a

 

■  

SMOTHER FLAMES with a close fitting lid, cookie sheet, or 
metal tray, then turn off the burner. BE CAREFUL TO 
PREVENT BURNS. If the flames do not go out 
immediately, EVACUATE AND CALL THE FIRE 
DEPARTMENT.

■  

NEVER PICK UP A FLAMING PAN - you may be burned.

■  

DO NOT USE WATER, including wet dishcloths or towels - 
a violent steam explosion will result.

■  

Use an extinguisher ONLY if:

– You know you have a class ABC extinguisher, and you 

already know how to operate it.

– The fire is small and contained in the area where it 

started. 

– The fire department is being called.

– You can fight the fire with your back to an exit.

a

Based on "Kitchen Fire Safety Tips" published by NFPA.

■  

WARNING: 

To reduce the risk of fire or electrical shock, 

do not use this fan with any solid-state speed control 
device.

Summary of Contents for RH3736XL

Page 1: ...E 30 76 2 CM ET 36 91 4 CM Instructionsd installationetGuided utilisationetd entretien Table of Contents Table des matières 2 IMPORTANT READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY IMPORTANT LIRE ET CONSERVER CES INSTRUCTIONS POUR UTILISATION RÉSIDENTIELLE UNIQUEMENT 99043792C 9763366C ...

Page 2: ...lectrique 21 Achever l installation 22 UTILISATION DE LA HOTTE 22 Commandes de la hotte de cuisinière 22 ENTRETIEN DE LA HOTTE 22 Nettoyage 22 ASSISTANCE OU SERVICE 23 GARANTIE 23 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to ...

Page 3: ...efrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other utilities Ducted fans must always be vented outdoors CAUTION For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to ...

Page 4: ... dimensions provide minimum clearance Consult the cooktop range manufacturer installation instructions before making any cutouts Grounded electrical outlet is required See Electrical Requirements section The hood is factory set for vented installations For non vented recirculating installations charcoal filter pad Part Number 4396846 is available from your dealer All openings in ceiling and wall w...

Page 5: ...possible to where the vent system enters the heated portion of the house Makeup Air Local building codes may require the use of make up air systems when using ventilation systems greater than specified CFM of air movement The specified CFM varies from locale to locale Consult your HVAC professional for specific requirements in your area Venting Methods Vent system can terminate either through the ...

Page 6: ...ed and UL listed for joining copper to aluminum Follow the electrical connector manufacturer s recommended procedure Aluminum copper connection must conform with local codes and industry accepted wiring practices Wire sizes and connections must conform with the rating of the appliance as specified on the model serial rating plate The model serial plate is located behind the filter on the rear wall...

Page 7: ...ne that is 2 5 0 cm from back wall Drill a 1 3 0 cm diameter hole through the cabinet at this point To wire through rear wall Mark a line 7 19 0 cm from the right of the centerline on the wall Mark the point on this line that is 1 9 cm from underside of cabinet Drill a 1 3 0 cm diameter hole through wall at this point Style 1 Cut Openings for 3 x 10 8 3 cm x 25 4 cm Rectangular Vent System Roof Ve...

Page 8: ...o make a 4 x 10 10 2 x 26 7 cm rectangular cutout on the underside of cabinet bottom 1 Mark lines 1 3 8 cm and 5 14 0 cm from the back wall on the centerline of the underside of cabinet 2 Mark lines 5 13 3 cm to the right and left of the centerline on the underside of cabinet 3 Use saber or keyhole saw to cut a rectangular opening for vent To make a 7 18 4 cm circle on the underside of the cabinet...

Page 9: ...ace 5 Use 3 mm drill bit and drill 4 pilot holes as shown 6 Install the 4 10 x mounting screws in pilot holes Leave about 6 4 cm space between screw heads and cabinet to slide range hood into place 7 For Direct Wire Installations Install a UL listed or CSA approved strain relief Pull about 12 30 0 cm of wire through wall or cabinet and into opening For Power Supply Installations Follow instruction...

Page 10: ...on for installation instructions Check Range Hood Operation 1 Check light operation by turning the light knob 2 Check operation of fan by turning the fan knob 3 If the range hood does not operate check to see whether a circuit breaker has tripped or a house fuse has blown 4 NOTE To get the most efficient use from your new range hood read the Range Hood Use section RANGE HOOD USE The range hood is ...

Page 11: ... recommend that you use only factory specified parts Factory specified parts will fit right and work right because they are made with the same precision used to build every new appliance To locate factory specified parts replacement parts in your area call us or your nearest Whirlpool designated service center IntheU S A Call the Whirlpool Customer eXperience Center toll free 1 800 253 1301or visi...

Page 12: ...ice by an authorized Whirlpool servicer is not available 10 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not installed in accordance with published installation instructions 11 Major appliances with original model serial numbers that have been removed altered or cannot be easily determined This warranty is void if the factory applied s...

Page 13: ...as de non respect des instructions Votre sécurité et celle des autres est très importante Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager Assurez vous de toujours lire tous les messages de sécurité et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de sécurité Ce symbole d alerte de sécurité vous signale les dangers potentiel...

Page 14: ... extérieur ne pas décharger l air aspiré dans un espace vide du bâtiment comme une cavité murale un plafond un grenier un vide sanitaire ou un garage AVERTISSEMENT POUR RÉDUIRE LE RISQUE D INCENDIE UTILISER UNIQUEMENT DES CONDUITS MÉTALLIQUES AVERTISSEMENT POUR MINIMISER LE RISQUE D UN FEU DE GRAISSE SUR LA CUISINIÈRE Ne jamais laisser un élément de surface fonctionner à puissance de chauffage max...

Page 15: ...s et écrous pour la fixation des tringles d appui Exigencesd emplacement IMPORTANT Observer les dispositions de tous les codes et règlements en vigueur C est à l installateur qu incombe la responsabilité de respecter les distances de séparation exigées spécifiées sur la plaque signalétique de l appareil La plaque signalétique est située à l intérieur de la hotte sur la paroi arrière Installer la h...

Page 16: ...rt à l élément d isolation thermique L élément d isolation thermique doit être aussi proche que possible de l endroit où le système d évacuation s introduit dans la partie chauffée de la maison Air d appoint Le code du bâtiment local peut exiger l emploi d un système d appoint d air lors de l emploi d un ventilateur d extraction dont la capacité d aspiration est supérieure à un débit pieds cubes p...

Page 17: ...otection Association One Batterymarch Park Quincy MA 02269 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 L appareil doit être alimenté par un circuit de 120 V CA seulement 60 Hz 15 ampères protégé par fusible Composant Conduit de diamètre 7 17 8 cm Coude à 45 2 5 pi 0 8 m Coude à 90 5 pi 1 5 m Bouche de décharge murale de 7 17 8 cm 0 pi 0 m 3 x 10 8 3 cm x 25 4 cm à 7 17...

Page 18: ... Sélectionner une surface plane pour l assemblage de la hotte Placer le matériau de protection sur cette surface 3 À l aide de 2 personnes ou plus soulever la hotte et la poser sur la surface couverte 4 Si le fond du placard forme une cavité ajouter des tringles d appui en bois de chaque côté Installer les vis pour fixer les tringles d appui aux emplacements indiqués Déterminer l emplacement du tr...

Page 19: ...2 7 cm en partant du mur arrière sur la partie inférieure du sommet du placard 3 Tracer un cercle en utilisant un compas ou un gabarit circulaire de 7 18 4 cm 4 Utiliser une scie sauteuse ou une scie à guichet pour découper une ouverture de 7 18 4 cm de diamètre 5 Répéter les étapes 1 à 4 pour la paroi du sommet du placard Style 3 Découpage d ouverture pour un conduit rectangulaire de 3 x 10 8 3 x...

Page 20: ... sommet l opercule rectangulaire et l opercule en demi cercle Si la hotte doit être accessible à un conduit d évacuation rectangulaire installer le connecteur rectangulaire avec clapet Réinstaller le connecteur de conduit rond REMARQUE Si la bouche de décharge murale est située directement derrière le connecteur de conduit on doit veiller à empêcher toute interférence entre les clapets du connecte...

Page 21: ...t par câblage direct 1 Connecter ensemble le conducteur blanc du câble d alimentation et le conducteur blanc de la hotte avec un connecteur de fils homologation UL 2 Connecter ensemble le conducteur noir du câble d alimentation et le conducteur noir de la hotte avec un connecteur de fils homologation UL 3 Connecter le conducteur vert ou nu de liaison à la terre du câble d alimentation à la vis ver...

Page 22: ... LIGHT éclairage est représenté à la position d extinction Pour une intensité d éclairage maximum faire pivoter le bouton de 45 dans le sens horaire Pour le niveau d éclairage minimum faire encore pivoter le bouton de 45 dans le sens horaire Fonctionnement du ventilateur Le bouton de commande FAN ventilateur est représenté à la position d extinction Pour commander la mise en marche du ventilateur ...

Page 23: ... ménager est utilisé et entretenu conformément aux instructions jointes à ou fournies avec le produit Whirlpool Corporation ou Whirlpool Canada LP ci après désignées Whirlpool paiera pour les pièces spécifiées par l usine et la main d œuvre pour corriger les vices de matériaux ou de fabrication Le service doit être fourni par une compagnie de service désignée par Whirlpool Cette garantie limitée e...

Page 24: ...DROITS JURIDIQUES SPÉCIFIQUES ET VOUS POUVEZ ÉGALEMENT JOUIR D AUTRES DROITS QUI PEUVENT VARIER D UNE JURIDICTION À UNE AUTRE Si vous résidez à l extérieur du Canada et des 50 États des États Unis contactez votre marchand Whirlpool autorisé pour déterminer si une autre garantie s applique Si vous avez besoin de service voir d abord la section Dépannage du Guide d utilisation et d entretien Après a...