background image

Write the model and serial  

numbers here:

Model # _________________

Serial # _________________

You can find them on a label 

on the inside of the hood.

ESPAÑOL

Para consultar una version en 

español de este manual de 

instrucciones, visite nuestro sitio de 

internet GEAppliances.com.

VENTED RANGE 

HOODS

49-2000708  Rev. 0   03-21   GEA

GE is a trademark of the General Electric Company. Manufactured under trademark license.

SAFETY INFORMATION

  . . . . . . . . . . . . .3

USING THE HOOD

Controls  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5

Wi-Fi Connect . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Filters  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

CARE AND CLEANING

Surfaces  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

Lights  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8

INSTALLATION INSTRUCTIONS

  . . . 9

TROUBLESHOOTING TIPS

  . . . . . . . . . 25

LIMITED WARRANTY

  . . . . . . . . . . . . . . 26

ACCESSORIES

  . . . . . . . . . . . . . . . . . . . . . . 27

CONSUMER SUPPORT

  . . . . . . . . . . . . . 28 

UVW8304

UVW8364

OWNER’S MANUAL 

& INSTALLATION 

INSTRUCTIONS

Summary of Contents for UVW8304

Page 1: ...itio de internet GEAppliances com VENTED RANGE HOODS 49 2000708 Rev 0 03 21 GEA GE is a trademark of the General Electric Company Manufactured under trademark license SAFETY INFORMATION 3 USING THE HOOD Controls 5 Wi Fi Connect 6 Filters 7 CARE AND CLEANING Surfaces 8 Lights 8 INSTALLATION INSTRUCTIONS 9 TROUBLESHOOTING TIPS 25 LIMITED WARRANTY 26 ACCESSORIES 27 CONSUMER SUPPORT 28 UVW8304 UVW8364...

Page 2: ...es into every GE Appliances product and we think you will too Among other things registration of your appliance ensures that we can deliver important product information and warranty details when you need them Register your GE appliance now online Helpful websites and phone numbers are available in the Consumer Support section of this Owner s Manual You may also mail in the pre printed registratio...

Page 3: ...HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS CAUTION TO REDUCE RISK OF FIRE AND TO PROPERLY EXHAUST AIR BE SURE TO DUCT AIR OUTSIDE DO NOT VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS CRAWL SPACES OR GARAGES WARNING TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE OBSERVE THE FOLLOWING A SMOTHER FLAMES with a close fitting lid cookie sheet or m...

Page 4: ...Association NFPA the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities C When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities D Ducted fans must always be vented to the outdoors E When applicable install any makeup replacement air system in accordance with local building code requireme...

Page 5: ... function of each control button are noted below 2 Fan On Off On Off switch for the fan The fan can be operated by pressing any of the fan setting buttons Hold Power for 3 seconds to activate Delay Off feature which automatically turns the fan off after 15 minutes Low Med and High buttons LEDs will rolling blink to indicate Delay Off feature is activated 3 Fan Settings Speed control for fan Press ...

Page 6: ...router Have this password ready while you are setting up your GE Appliances hood Connect your GE Appliances hood 1 On your smart phone or tablet visit GEAppliances com connect to learn more about connected appliance features and to download the appropriate app 2 Follow the app onscreen instructions to connect your GE Appliances hood 3 Once the process is complete the indicator light located on you...

Page 7: ... installation only NOTE DO NOT rinse or put charcoal filter in an automatic dishwasher The charcoal filter is NOT included with the unit Order charcoal filter UXCF91 It cannot be cleaned it must be replaced It is recommended that the charcoal filter be replaced every 6 months or if it is noticeably dirty or discolored To reduce the risk of fire and shock when used in recirculation mode use only ch...

Page 8: ...iend Soft Cleanser will remove surface rust tarnish and small blemishes Use only a liquid cleanser free of grit and rub in the direction of the brush lines with a damp soft sponge To inquire about purchasing stainless steel appliance cleaner or polish or to find the location of a dealer nearest you please call our toll free number National Parts Center 800 626 2002 GEApplianceParts com Surfaces CA...

Page 9: ...ch as a tag to the service panel CAUTION Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION WARNING Disconnect all electrical power at the main circuit breaker or fuse box before installing WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Inst...

Page 10: ...rewdriver with at least 6 shank Strain relief for junction box Strain Relief I Electric drill with 2 Phillips and 1 8 and 5 16 drill bits UL listed wire nuts 8 round duct Wire Nuts Pencil and tape measure Gloves REMOVE THE PACKAGING CAUTION Wear gloves to protect against sharp edges Remove the hardware bag literature package and other boxed parts Remove and properly discard the protective plastic ...

Page 11: ...e to the product or personal injury NOTE This rangehood can be installed as either ducted or recirculation In a ducted application this rangehood can be vented through the wall or ceiling When installed for recirculation the rangehood vents out the sides of the duct cover NOTE Before making any cuts or holes for installation determine which venting method will be used and carefully calculate all m...

Page 12: ...ounting brackets to secure duct covers to the wall When not recirculating holes can be hidden by turning the upper duct cover upside down For ceiling installations up to 10 8 use the 10 High Ceiling Duct Cover kit CX10DC9SPSS For higher ceiling installations up to 12 8 use the 12 High Ceiling Duct Cover kit CX12DC9SPSS See the next page for duct cover installation height information X Distance fro...

Page 13: ...4 27 24 31 8 2 30 24 27 24 32 9 3 30 24 28 24 32 8 3 30 31 24 28 24 33 9 4 30 31 24 29 24 33 8 4 30 32 24 29 24 34 9 5 30 32 24 30 24 34 8 5 30 33 24 30 24 35 9 6 30 33 24 31 24 35 8 6 30 34 24 31 24 36 9 7 30 30 34 24 32 24 36 8 7 30 30 35 24 32 9 8 30 31 30 35 24 33 8 8 30 31 30 36 24 33 9 9 30 32 30 36 24 34 8 9 30 32 24 34 9 10 30 33 24 35 8 10 30 33 24 35 9 11 30 34 24 36 8 11 30 34 24 36 10 ...

Page 14: ...ation and must be purchased separately Power Supply Planning The location of the power supply connection is called out in the section House Wiring Location Roof Cap Round Duct Wall Cap Add Insulation and or Caulk Add Insulation and or Caulk Add tape to joint Hood POWER SUPPLY IMPORTANT Please read carefully WARNING FOR PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED Remove house fuse or o...

Page 15: ...ooking surface 24 minimum over electric range or 30 minimum over gas range and 36 recommended maximum Use a level to draw a horizontal line indicating the bottom of the hood Use a level to draw the cooktop or range centerline location Measure 9 up from the horizontal line for the bottom of the hood Draw another horizontal line to indicate the bottom of the installation bar For Vertical Straight Up...

Page 16: ...he top of the hood at the right side To route house wiring through the ceiling soffit or cabinet Cut a hole approximately 1 1 4 dia forward on the ceiling at a distance 9 3 4 to the left of the centerline To route house wiring through the wall Measure 7 3 4 from the bottom of the hood and mark location Cut a hole approximately 1 1 4 dia at the marked location at a distance 9 3 4 to the left of the...

Page 17: ...body using screws B from the top of the hood as shown in image below Use duct tape to seal the connection 3 INSTALL HOOD ONTO WALL Pull house wiring through knockout at the back or top of the hood Lift the hood and place over the hooks on the installation bar Allow the hood to slide down into position Check to be sure the hood is level and centered Tighten wall anchor screws C to finish hood body ...

Page 18: ...ontal wood supports This is the vertical distance between mounting screw holes and back wall as shown in Figure C For top venting allow minimum opening Dim B to accommodate damper in soffit or cabinet Drive mounting Screws A into the studs until they protrude 1 4 This 1 4 gap will provide clearance to engage the keyhole slots in the top of the hood The hood must also be secured to the back wall Fo...

Page 19: ...ns Remove junction box cover Pull the house wiring through the knockout at the top or back of the hood and secure with the strain relief Use UL listed wire nuts to connect incoming white to white and black to black wires Loosen the green grounding screw with grounding bracket in the junction box Loop solid copper house wire clockwise around the green grounding screw and above the bracket Firmly ti...

Page 20: ... operations Seal connection with tape only B Recirculation non vented Installation NOTE A recirculation duct WB34X30519 and Charcoal Filter UXCF91 are not included with the hood and are necessary for recirculation installation 1 Attach the recirculation duct to the duct cover mounting bracket with screws provided 2 Connect the ducting from the exhaust outlet on the hood to the recirculation duct U...

Page 21: ...e available at GEApplianceparts com or by calling 877 959 8688 See Accessories on page 27 Follow instructions included with the duct cover accessory to install duct covers 9 INSTALL FILTERS Follow instructions on page 7 Filters to install or remove filters INSTALLATION INSTRUCTIONS Filter Lock ...

Page 22: ...s described below 1 Remove the grease filters 2 Disconnect all the harnesses from the top control box located on right side of motor 3 Loosen the screws on top of control box and slide out to remove it from the hood 4 Uninstall the control box cover 5 For a maximum of 390 CFM with 4 speeds Low Medium High and Boost i Disconnect connectors of the BROWN wire ii Remove the cap attached to the connect...

Page 23: ...49 2000708 REV 0 23 Notes ...

Page 24: ...24 49 2000708 REV 0 Notes ...

Page 25: ... or moves air slower than normal and or fan is making loud or abnormal airflow noise Obstructions in duct work Make sure nothing is blocking the vent Make sure your wall or roof cap has a blade or door Damper blade on wall or roof cap may not be open Make sure damper swings freely Damper blades may flip over and will not fully open when this happens Adjust to original position Metal grease filter ...

Page 26: ...Y GE Appliances Vented Range Hood Warranty EXCLUSION OF IMPLIED WARRANTIES Your sole and exclusive remedy is product repair as provided in this Limited Warranty Any implied warranties including the implied warranties of merchantability or fitness for a particular purpose are limited to one year or the shortest period allowed by law This limited warranty is extended to the original purchaser and an...

Page 27: ... the Consumer Support page for phone numbers and website information The following products and more are available Accessories Parts Grease filters Duct Covers Charcoal Filters Recirculation Kit Remote Control 15 cabinet filler panel Power Cord kit Cleaning Supplies CitruShine Stainless Steel Wipes Stainless Steel Appliance Cleaner Bar Keepers Friend Soft Cleanser ...

Page 28: ...ill in effect You can purchase it on line anytime GE Appliances Services will still be there after your warranty expires In the US GEAppliances com ge service and support shop for extended service plans htm or call 800 626 2224 during normal business hours Remote Connectivity For assistance with wireless network connectivity for models with remote enable visit our website at GEAppliances com ge co...