4
Location Requirements
NOTES:
■
The flexible exhaust hose allows placement of the air
conditioner between 19
¹⁄₂
" and 70
⁵⁄₈
" (49.5 cm and 180 cm)
from window or door.
■
Portable air conditioners are designed as supplemental
cooling to local areas within a room.
Vertical Slide Window
Horizontal Slide Window
■
To ensure proper ventilation, keep the required distance from
the return air outlet to the wall or other obstacles at least
19
¹⁄₂
" (49.5 cm).
■
Do not block air outlet.
■
Provide easy access to grounded 3 prong outlet.
Electrical Requirements
■
The portable air conditioner should be connected to a 115 V,
60 Hz, 15-amp fused grounded 3 prong outlet.
■
The use of a time-delay fuse or time-delay circuit breaker is
recommended.
■
All wiring must comply with local and national electrical
codes and be installed by a qualified electrician. If you have
any questions, contact a qualified electrician.
Power Supply Cord
NOTE: Your air conditioner’s device may differ from the one
shown.
This room air conditioner is equipped with a power supply cord
required by UL. This power supply cord contains state-of-the-art
electronics that sense leakage current. If the cord is crushed, the
electronics detect leakage current and power will be
disconnected in a fraction of a second.
19
¹⁄₂
" - 70
5
/
8
"
(49.5 cm - 180 cm)
19
1
/
2
" - 70
5
/
8
"
(49.5 - 180 cm)
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
A. Test button
B. Reset button
TEST
RESET
A
B
Summary of Contents for PORTABLE AIR CONDITIONER
Page 17: ...17 Notes ...