34
MODELO
Kit de gas LP a gas natural
LWFR7300S
W11344945
LWFR7400S
W11344946
LWFR9000S
W11344947
LWFR7600S
W11353307
LWFR7100S, LWER5000S
W11209938
LWFR7200S
W11209939
CONNECTION OF THE RANGE TO THE GAS LINE FOR MODELS: LWFR7300,
LWFR7400, LWFR9000
A combination of splice pipes must be used to connect the range to the existing gas supply line.
Your connection may be different, according to the type of supply line, size and location.
1. To connect your range, use the material specified in the figure below:
2. Once your gas line is connected, OPEN the gas supply valve and check that there are no
leaks by pouring soap bubbles on the connections and elbows of the pipes.
3. Check that the copper pipe is not damaged or bent in a way that obstructs the passage of gas
to your range..
DO NOT USE FLAMES TO DETECT GAS LEAKS.
DO NOT USE PLASTIC HOSES FOR GAS CONNECTIONS BECAUSE THEY CAN LEAK, EVEN THOSE
THAT HAVE STEEL MESH ON THEIR SURFACE.
Recommendations:
•
If the installation is not new, clean the pipes to avoid plugging the nozzles.
•
In order to facilitate the movement of the appliance, the installer must make a coil with the
copper flexible pipe and install a shutoff valve in the gas supply line. This valve must be
outside the range and accessible to the people who use it.
•
Always use pipes and pressure regulators according to local regulations.
•
Check the validity of the tubes and pressure regulators and replace them if necessary.
•
Tighten all gas connections properly during installation.
•
When moving your range, avoid damaging the gas connection to avoid gas leakage.
Gas Supply Requirements
This range is ready to work with L.P. gas from a mobile or stationary tank.
To use your range with natural gas (pipe) you must call Whirlpool Service to change the nozzle
and make the necessary adjustments. See the “Service” section on p. 22
The qualified technician must carry out the conversion of both the upper burner jets and the
range regulator (in case the model has this); you must make sure that the connection is not
leaking and that the gas pressure in the stove is as shown below:
NOTE: The type of gas used by this stove is LP gas “G30” [third family (group 3B / P)], to operate this stove
with Natural Gas [first family (group 2H)], the conversion kit is required. according to the following table and
you can request it with your Authorized Whirlpool Solutions Center, otherwise your stove will generate soot
and this will incur a cleaning service, which is not included in the product warranty, to change the injectors
and make the necessary adjustments.
Operative pressure LP gas
2.75kPa< 2750 Pa< 27.5 mbar
28 cm water column
Operative pressure LP gas
1.76 kPa< 1760 Pa< 17.6 mbar
18 cm water column
Stove
regulator
NOTE: The material shown for this installation does not come with the stove.
Copper tube with
9.4mm (3/4 “)
conical nuts
3/8 “9.5mm stopcock
Copper tube with conical
nuts 9.5mm (3/8 “) in length
necessary to reach the gas
9.5mm
Cople-nipple
(3/8 NPT)
Gas
regulator
17-Sep-2019 13:32:01 EDT | RELEASED
In some European factories the letter "W" of the part code mentioned herein will be automatically
replaced by the number "4000" (e.g. "W12345678" becomes "400012345678")