background image

#

Error Code

Root Cause Error

1

E901

When the bubble finally detected excessive 
dehydration or the load is too large, after adjustment 
still detects excessive foam or the load is too large; 
detecting the input current is too large

2

U3

Final dehydration detected eccentric too large, the 
adjustment is still detected too eccentric

3

U4

Door locker abnormal

4

H

Barrel temperature is high, for cooling process, the 
temperature is lowered to unlock

5

O3H

High barrel ozone concentration, ozone decomposition 
wait to unlock the safe concentration

6

E11

When the water fill ,It does not reached the set level 
within a predetermined time

7

E12

When draining, reset level not reached within a 
predetermined time

8

EC2

Water heating thermistor short circuit or disconnection

9

EC3

Dehumidification water thermistor short circuit or 
disconnection

10

EC5

Drying duct thermistor short circuit or disconnection

11

EA1

Abnormal water level sensor

12

EA2

Unusual high water level during wash, rinse cycle  

13

EA3

The water level is higher than the set level during spin

14

EF2

After power-up, the zero-crossing signal is not received

15

EU

Power outage, do not open the power relay off

#

Error Code

Root Cause Error

16

E7C

When heated ,the heater did not work properly

17

E6C

When no heating , It detects abnormal water heating 

pipe work

18

EC6

When not in the drying process, the drying heating 

pipe detected abnormal operation

19

EC7

When drying, drying heating pipe is detected is not 

working properly (detection PCB)

20

E00

No normal ozone generator

21

E01

Ozone generator abnormal operation

22

777

Displaying the received signal is less than the master 

communication

Ed2

Master displays the communication signal can not be 

received

Ed1

Master and inverter communication error

23

E902

Power supply voltage is too high

24

E904

Power supply voltage is too low

25

E908

Motor fail

26

E910

Frequency part of the current detecting abnormal

27

E920

IPM abnormality

28

E940

Hall signal abnormality

Summary of Contents for IFW Series

Page 1: ...IFW Series Error Code List and Diagnostic Codes ...

Page 2: ... the Drain Hose is inverted Whether the Drain Hose is blocked by scrap of lint Whether the Drain Hose is too long Check and resolve the problem then press START PAUSE for one time to restart the washer H Door fails to open Whether the temperature of water exceeded 40 C Whether the temperature of water in washing process exceeded 40 C The door will open automatically as soon as the temperature is b...

Page 3: ...ircuitordisconnection 11 EA1 Abnormalwaterlevelsensor 12 EA2 Unusualhighwaterlevelduringwash rinsecycle 13 EA3 Thewaterlevelishigherthanthesetlevelduringspin 14 EF2 Afterpower up thezero crossingsignalisnotreceived 15 EU Poweroutage donotopenthepowerrelayoff ErrorCode RootCauseError 16 E7C Whenheated theheaterdidnotworkproperly 17 E6C Whennoheating Itdetectsabnormalwaterheating pipework 18 EC6 Whe...

Page 4: ...e or the metal filter Arrange the wiring correctly The 3 red chips power terminal Is there 0V voltage between the orange gray lines when the valve assembly rest Is there 220VAC between the orange gray line Replace the valve assembly Replace the control circuit board Yes Yes Yes Yes Yes No No No No Water does not flow into the Wash Spin Tub or water flow is very little ...

Page 5: ...ning Is there the foreign matter in the drain system Clear out the drain pipe system The 3 yellow chip power terminals When the drain valve works is there 220VAC between the blue violet lines When the drain valve turns off is there 220VAC voltage between the blue black lines Clear out the foreign matter in drain valve Replace the control circuit board Yes Yes Yes Yes No No No No Washer is not drai...

Page 6: ...EA1 Replace display board The water level sensor s damage is few Replace the water level sensor Abnormal condition of water level sensor ...

Page 7: ...GNOSTIC TEST 1 Hold Delay Start 2 Push Power 3 Push Start Pause three times 100ms interval 4 Push Delay Start 5 Push Express wash 6 Push Rinse 7 Push Temp 8 Push Spin Speed 9 Push Start Pause 10 Hold Delay Start 0 8 seconds ...

Page 8: ......

Page 9: ...t Pause three times 100ms interval 4 Push Delay Start until 00 5 Push Express Wash to show 01 Push Start Drum rotate CCW CW 02 Push Start Force spin 03 Push Start Balance check 6 When step 4 shows 00 turn 6th Sense knob to Down and then Start to force fill water check water valve ...

Page 10: ......

Page 11: ...HOW TO FORCE WATER FILL 1 Hold Rinse 2 Push Power 3 Push Start Pause three times 100ms interval 4 Push Delay Start until 00 5 Turn the knob to Down 6 Press Start ...

Reviews: