48
■
Furnace fails to
operate.
■
Integrated
control module
LED display
provides “b1”
error code.
b1
■
Integrated
control module
has lost
communication
s with circulator
blower motor.
■
Loose wiring
connection at
circulator motor
control leads.
■
Failed circulator
blower motor.
■
Failed integrated
control module.
■
Tighten or correct
wiring connection.
■
Check circulator
blower motor. Replace
if necessary.
■
Check integrated
control module.
Replace if necessary.
■
Turn off power prior to
repair.
■
Replace circulator
motor with correct
replacement part.
■
Replace integrated
control module with
correct replacement
part.
■
Furnace fails to
operate.
■
Integrated
control module
LED display
provides “b2”
error code.
b2
■
Circulator
blower motor
horse power in
shared data set
does not match
circulator
blower motor
horse power.
■
Incorrect circulator
blower motor in
furnace.
■
Incorrect shared
data set in
integrated control
module.
■
Verify circulator blower
motor horse power is
the same specified for
the specific furnace
model. Replace if
necessary.
■
Verify shared data set
is correct for the
specific model.
Repopulate data using
correct memory card, if
required.
■
Turn off power prior to
repair.
■
Replace motor with
correct replacement
part.
■
Use memory card for
the specific model
■
Insert memory card
before turning on
power. Memory card
may be removed after
data is loaded.
■
Turn off power before
removing memory
card.
■
Error code will be
cleared once shared
data and motor horse
power match.
■
Furnace
operates at
reduced
performance.
■
Airflow
delivered is less
than expected.
■
Integrated
control module
LED display
provides “b3”
error code.
b3
■
Circulator
blower motor is
operating in a
power,
temperature or
speed limiting
condition.
■
Blocked filters.
■
Restrictive
ductwork.
■
Undersized
ductwork.
■
High ambient
temperatures.
■
Check filters for
blockage. Clean filters
or remove obstruction.
■
Check ductwork for
blockage. Remove
obstruction. Verify all
registers are fully open.
■
Verify ductwork is
appropriately sized for
system. Resize/replace
ductwork if necessary.
■
See “Product
Description” and
“Location
Requirements and
Considerations” for
furnace installation
requirements.
■
Turn off power prior to
repair.
■
Furnace fails to
operate.
■
Integrated
control module
LED display
provides “b4”
error code.
b4
■
Circulator
blower motor
senses a loss of
rotor control.
■
Circulator
blower motor
senses high
current.
■
Abnormal motor
loading, sudden
change in speed or
torque, sudden
blockage of
furnace air inlet or
outlet.
■
High loading
conditions, blocked
filters, very
restrictive
ductwork,
blockage of
furnace air inlet or
outlet.
■
Check filters, filter
grills/registers, duct
system and furnace air
inlet/outlet for
blockages.
■
Turn off power prior to
repair.
Symptoms of
Abnormal
Operation
Diagnostic/
Staus LED
Code
Fault Description Possible Causes
Corrective Actions
Notes and Cautions