49
DIP Switch Chart
Switch DIP
Switch
Number
Bank
Purpose
Function
1
2
3
4
5
6
7
8
9
10
S1
Heat Off
Delay
90 Seconds
Off
Off
---
---
---
---
---
---
---
---
120 Seconds
On
Off
---
---
---
---
---
---
---
---
150 Seconds*
Off
On
---
---
---
---
---
---
---
---
180 Seconds
On
On
---
---
---
---
---
---
---
---
Thermostat
Setup
1-Stage T-Stat
---
---
Off
---
---
---
---
---
---
---
2-Stage T-Stat
---
---
On
---
---
---
---
---
---
---
5-Min Delay
---
---
---
Off
---
---
---
---
---
---
Auto Delay
---
---
---
On
---
---
---
---
---
---
S2
Bus BIAS
BIAS
On*
On*
---
---
---
---
---
---
---
---
TERM
Bus Termination
---
---
On*
---
---
---
---
---
---
---
S3
Cooling
Speed Tap
A
Off
Off
---
---
---
---
---
---
---
---
B
On
Off
---
---
---
---
---
---
---
---
C
Off
On
---
---
---
---
---
---
---
---
D*
On
On
---
---
---
---
---
---
---
---
Adjust Taps Normal*
---
---
Off
Off
---
---
---
---
---
---
10%
---
---
On
Off
---
---
---
---
---
---
-10%
---
---
Off
On
---
---
---
---
---
---
Normal
---
---
On
On
---
---
---
---
---
---
S4
Ramping
Profiles
A*
---
---
---
---
Off
Off
---
---
---
---
B
---
---
---
---
On
Off
---
---
---
---
C
---
---
---
---
Off
On
---
---
---
---
D
---
---
---
---
On
On
---
---
---
---
Heating
Speed Tap
A
---
---
---
---
---
---
Off
Off
---
---
B*
---
---
---
---
---
---
On
Off
---
---
C
---
---
---
---
---
---
Off
On
---
---
D
---
---
---
---
---
---
On
On
---
---
S5
DEHUM
Disabled*
---
---
---
---
---
---
---
---
Off
Unused
Enabled
---
---
---
---
---
---
---
---
On
Unused
*Indicates factory setting
---
Not applicable
Goodman 118 Long
HIGH VOLTAGE!
WARNING
To avoid personal injury or death due to electrical shock, disconnect electrical power
before performing any service or maintenance.